Abstract
In this paper, an electrochemical magneto-immunosensor for the detection of human growth hormone (hGH) is described for the first time. The immunosensor involves the use of tosyl-activated magnetic microparticles (TsMBs) to covalently immobilize a monoclonal mAbhHG antibody. A sandwich-type immunoassay with a secondary pAbhGH antibody and anti-IgG labelled with alkaline phosphatase (anti-IgG-AP) was employed. TsMBs–mAbhGH–hGH–pAbhGH–anti-IgG-AP conjugates were deposited onto the surface of a screen-printed gold electrode using a small neodymium magnet, and electrochemical detection was performed by square-wave voltammetry upon the addition of 4-aminophenyl phosphate as the AP substrate. All the variables involved in the preparation of immunoconjugates and in the immunoassay protocol were optimized. A calibration curve for hGH was constructed with a linear range between 0.01 and 100 ng/mL (r = 0.998) and a limit of detection of 0.005 ng/mL. This value is nearly three orders of magnitude lower than that obtained using surface plasmon resonance (Treviño et al., Talanta 78:1011–1016, 2009). Furthermore, good repeatability, with RSD = 3% (n = 10) at the 1-ng/mL hGH level, was obtained. Cross-reactivity studies with other hormones demonstrated good selectivity. The magneto-immunosensor was applied to the analysis of human serum spiked with hGH at the 4- and 0.1-ng/mL levels. Mean recoveries of 96 ± 6% and 99 ± 2%, respectively, were obtained.
Similar content being viewed by others
References
Popii V, Baumann G (2004) Clin Chim Acta 350:1–16
Bowes SB, Umpleby M, Cummings MH, Jackson NC, Carroll PV, Lowy C, Sonksen PH (1997) J Clin Endocrinol Metab 82:243–246
Strasburger CJ (1999) Pediatrics 104:1024–1028
Rix M, Laurberg P, Hoejberg AS, Brock-Jacobsen B (2005) Eur J Endocrinol 153:195–210
D’Orazio P (2003) Clin Chim Acta 334:41–69
Albersoon-Wikland K, Jansson C, Rosberg S, Novamo A (1993) Clin Chem 39:1620–1625
Langkamp M, Weber K, Ranke MB (2008) Growth Horm IGF Res 18:526–532
Treviño J, Calle A, Rodríguez-Frade JM, Mellado M, Lechuga LM (2009) Talanta 78:1011–1016
Treviño J, Calle A, Rodríguez-Frade JM, Mellado M, Lechuga LM (2009) Clin Chim Acta 403:56–62
Reazaei B, Khayamian T, Majidi N, Rahmani H (2009) Biosens Bioelectron 25:395–399
D´Orazio P (2011) Clin Chim Acta 412:1749–1761
Ricci F, Volpe G, Micheli L, Palleschi G (2007) Anal Chim Acta 605:111–129
Jiang X, Li D, Xu X, Ying Y, Li Y, Ye Z, Wang Y (2008) Biosens Bioelectron 23:1577–1587
Yuan Y-R, Yuan R, Chai Y-Q, Zhuo Y, Miao X-M (2009) J Electroanal Chem 626:6–13
Jiang W, Yuan R, Chai Y-Q, Yin B (2010) Anal Biochem 407:65–71
Liu S, Zhang X, Wu Y, Tu Y, He L (2008) Clin Chim Acta 395:51–56
Silva BVM, Cavalcanti IT, Mattos AB, Moura P, Sotomayor MPT, Dutra RF (2010) Biosens Bioelectron 26:1062–1067
Ferapontova EE, Olsen EM, Gothelf KV (2008) J Am Chem Soc 130:4256–4258
Carralero V, González-Cortés A, Yáñez-Sedeño P, Pingarrón JM (2007) Anal Chim Acta 596:86–91
Lu H, Conneely G, Pravda M, Guilbault GG (2006) Steroids 71:760–767
Richardson J, Hawkins P, Luxton R (2001) Biosens Bioelectron 16:989–993
Centi S, Laschi S, Mascini M (2007) Talanta 73:394–399
Lin Y-Y, Liu G, Wai CM, Lin Y (2007) Electrochem Commun 9:1547–1552
Laube T, Kergaravat SV, Fabiano SN, Hernandez SR, Alegret S, Pividori MI (2011) Biosens Bioelectron 27:46–52
Campuzano S, Esteban-Fernández de Ávila B, Yuste J, Pedrero M, García JL, García P, García E, Pingarrón JM (2010) Biosens Bioelectron 26:1225–1230
Bonel L, Vidal JC, Duato P, Castillo JR (2011) Biosens Bioelectron 26:3254–3259
Eguílaz M, Moreno-Guzman M, Campuzano S, González-Cortés A, Yáñez-Sedeño P, Pingarrón JM (2010) Biosens Bioelectron 26:517–522
Moreno-Guzman M, González-Cortes A, Yañez-Sedeño P, Pingarron JM (2011) Anal Chim Acta 692:125–130
Zacco E, Adrian J, Galve R, Marco MP, Alegret S, Pividori MI (2007) Biosens Bioelectron 22:2184–2191
Ito S, Yamazaki S, Kano K, Ikeda T (2000) Anal Chim Acta 424:57–63
Bard AJ, Faulknert LR (2001) Electrochemical methods. Fundamentals and applications, 2nd edn. Wiley, New York, p 293
Kreuzer MP, O'Sullivan CK, Guilbault GG (1999) Anal Chim Acta 393:95–102
Díaz-González M, González-García B, Costa-García A (2006) Sens Actuators B 113:1005–1011
Acknowledgements
Financial support from the Ministerio de Ciencia e Innovación (Projects DPS2008-07005-C02-01 and CTQ2009-12650), as well as of Comunidad de Madrid S2009/PPQ-1642, programme AVANSENS, is gratefully acknowledged.
Author information
Authors and Affiliations
Corresponding author
Additional information
Published in the special issue Euroanalysis XVI (The European Conference on Analytical Chemistry) with guest editor Slavica Ražić.
Rights and permissions
About this article
Cite this article
Serafín, V., Úbeda, N., Agüí, L. et al. Ultrasensitive determination of human growth hormone (hGH) with a disposable electrochemical magneto-immunosensor. Anal Bioanal Chem 403, 939–946 (2012). https://doi.org/10.1007/s00216-012-5753-9
Received:
Revised:
Accepted:
Published:
Issue Date: