Abstract.
Heavy alkylbenzene (HAB) is one of the by-products when producing linear alkylbenzene (LAB). Identification of the fine structures of HAB is difficult because of its complex structure and high boiling point. The gas chromatography/mass spectrometry (GC/MS) technique with a short glass capillary column is the best method applicable to analysis of high-boiling and thermally labile compounds. The column efficiency is evaluated on the basis of Van Deemter curves.
The experimental results show that the reduction in the optimum column efficiency for a short glass capillary column occurs along with a reduction in effective theoretical plates. A second important result is that the shift in the value of the flow velocity is related to the optimum point in height equivalent theoretical plate (HETP). The flow velocity is higher than that of conventional gas chromatography(GC).
The optimized conditions were used to analyse HAB produced through the hydrogen fluoride (HF) alkylation process. The results show acceptable relative separation of a product in an extended boiling point range. The optimized conditions were also used to analyse three other special samples supplied by BASF company's AlCl3 alkylation process and to approve the previous structures. The results also show that HAB from Iran Chemical Industries Investment Company (ICIIC) produced through LAB complex consists of an additional part and has more linearity than the other three samples of HAB obtained from BASF.
Similar content being viewed by others
References
De Almeida JLG, Dufaux M, Ben Taarit Y, Naccache C (1994) J Am Oil Chem Soc 71(7):675–694
Schoenkaes UDO (1998) LAS a modern classic surfactant. Chimica Oggi/Chemistry today
Radosavlijevic M, Melentijevic D, Tasic M (1987) Influence of impurities in feedstocks on dehydrogenation and alkylation reactions. CESIO
Porter MR (1991) Handbook of surfactants. Kluwer, Dordrecht pp 103–107
Rosen MJ (1989) Surfactants and interfacial phenomena. Wiley, New York
Davidson AS, Milwidsky B (1987) Synthetic detergents, 7th edn. Longman, Essex
UOP method 696–86 (1986) Product alkylbenzenes in detergent alkylate rerun bottoms by gas chromatography
UOP method 672–84 (1984) Aromatic hydrocarbon type in alkylates using low voltage mass spectrometry
ASTM method D 2425–88 (1988) Hydrocarbon types in middle distillates by mass spectrometry
ASTM method D 3239–91 (1991) Aromatic types of gas-oil aromatic fractions by high ionizing voltage mass spectrometry
Robinson CJ, Cook GL (1969) Anal Chem 41:1548–1554
Hamdi Hassan A, Naga EI, Abdel Azim M, Wedad, Sidaros KN (1987) Evaluation of sulphonated by-product of dodecylbenzene production. J Chem Tech Biotechnol 40:51–61
Hatch FW, Eparrish M (1978) Anal Chem 50(8)
Walsh JT, Merritte (1967) J Gas Chromatogr 5:420
Beynon JH, Saunders RA, Williams AE (1968) The mass spectra of organic molecules. pp 122–128
Acknowledgment.
The authors express their appreciation to the University of Kashan research councils for financial support of this work. M.Beiggy is grateful to ICIIC for performing the GC and GC/MS experiments.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ghoreishi, S.M., Beiggy, M. & Mazloum Ardekani, M. Optimization of gas chromatography using short glass capillary column with mass spectrometry for identification and evaluation of commercial heavy alkylbenzene structures. Anal Bioanal Chem 375, 1212–1220 (2003). https://doi.org/10.1007/s00216-003-1842-0
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-003-1842-0