Skip to main content
Log in

Calculated global end-diastolic volume does not correspond to the largest heart blood volume: a bias for cardiac function index?

  • Correspondence
  • Published:
Intensive Care Medicine Aims and scope Submit manuscript

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

References

  1. Michard F, Teboul JL (2002) Predicting fluid responsiveness in ICU patients. A critical analysis of the evidence. Chest 121:2000–2008

    Article  PubMed  Google Scholar 

  2. Combes A, Berneau JB, Luyt CE, Trouillet JL (2004) Estimation of left ventricular systolic function by single transpulmonary thermodilution. Intensive Care Med 30:1377–1383

    Article  PubMed  Google Scholar 

  3. Sakka SG, Rühl CC, Pfeiffer UJ, Beale R, Mc Luckie A, Reinhart K, Meier-Hellmann A (2000) Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution. Intensive Care Med 26:180–187

    Article  CAS  PubMed  Google Scholar 

  4. Wiesenack C, Prasser C, Keyl C, Rödijg G (2001) Assessment of intrathoracic blood volume as an indicator of cardiac preload: single transpulmonary thermodilution technique versus assessment of pressure preload parameters derived from a pulmonary artery catheter. J Cardiothorac Vasc Anesth 15:584–588

    Article  CAS  PubMed  Google Scholar 

  5. Michard F, Alaya S, Zarka V, Bahloul M, Richard C, Teboul JL (2003) Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock. Chest 124:1900–1908

    Article  PubMed  Google Scholar 

  6. Guyton AC (1991) Overview of the circulation, and medical physics of pressure, flow and resistance. In: Guyton AC (ed) Textbook of medical physiology 8th edn. Saunders, Philadelphia, pp 150–158

  7. Vieillard-Baron A, Schmitt JM, Beauchet A, Augarde R, Prin S, Page B, Jardin F (2001) Early preload adaptation in septic shock? A transesophageal echocardiographic study. Anesthesiology 94:400–406

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to François Gilles Brivet.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Brivet, F.G., Jacobs, F. & Colin, P. Calculated global end-diastolic volume does not correspond to the largest heart blood volume: a bias for cardiac function index?. Intensive Care Med 30, 2133–2134 (2004). https://doi.org/10.1007/s00134-004-2432-0

Download citation

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00134-004-2432-0

Keywords

Navigation