Abstract
Inner views of tubular structures based on computer tomography (CT) and magnetic resonance (MR) data sets may be created by virtual endoscopy. After a preliminary segmentation procedure for selecting the organ to be represented, the virtual endoscopy is a new postprocessing technique using surface or volume rendering of the data sets. In the case of surface rendering, the segmentation is based on a grey level thresholding technique. To avoid artifacts owing to the noise created in the imaging process, and to restore spurious resolution degradations, a robust Wiener filter was applied. This filter working in Fourier space approximates the noise spectrum by a simple function that is proportional to the square root of the signal amplitude. Thus, only points with tiny amplitudes consisting mostly of noise are suppressed. Further artifacts are avoided by the correct selection of the threshold range. Afterwards, the lumen and the inner walls of the tubular structures are well represented and allow one to distinguish between harmless fluctuations and medically significant structures.
Similar content being viewed by others
References
Vining DJ: Virtual endoscopy: Is it reality? Radiology 200:30–31, 1996
Kassam SA, Poor HV: Robust signal processing for communication systems. IEEE Comm Magazine 21:20–28, 1983
Lorensen WE, Cline HE: Marching cubes: A high resolution 3D surface reconstruction algorithm. Computer Graphics 21:163–169, 1987
Potter JD, Slattery ML: Colon cancer: A review of the epidemiology. Epidemiol Rev 15:499–545, 1993
Prince MR: Body MR angiography with gadolinium contrast agents. Magn Reson Imaging Clin N Am 4:11–24, 1996
Luboldt W, Bauerfeind P, Steiner P, et al: Preliminary assessment of three-dimensional magnetic resonance imaging for various colonic disorders. Lancet 349:1288–1291, 1997
Stoll E: Information- and Image-Processing of Scanning-Tunneling-Microscope Data. SPIE—Optics in Engineering Measurements 599:442–450, 1985
Stoll EP: Picture processing and three-dimensional visualization of data from scanning tunneling and atomic force microscopy. IBM J Res Develop 35:67–77, 1991
Stoll EP: Restoraton of STM images distorted by time-dependent piezo driver after-effects. Ultramicroscopy 42–44; 1585–1589, 1992
Huang TS, Schreiber WF, Tretiak OJ: Image Processing. Proc IEEE 59:1586–1609, 1971
Hara AK, Johnson CD, Reed JE, et al: Detection of colorectal polyps with CT colography: Initial assessment of sensitivity and specificity.” Radiology 205:59–65, 1997
Luboldt W, Steiner P, Bauerfeind P, et al: Detection of mass lesions with MR colonography: Preliminary report. Radiology 207:59–65, 1998
Author information
Authors and Affiliations
Additional information
This work is partly supported by the Swiss National Science Foundation.
Rights and permissions
About this article
Cite this article
Stoll, E., Stern, C., Stucki, P. et al. A new filtering algorithm for medical magnetic resonance and computer tomography images. J Digit Imaging 12, 23–28 (1999). https://doi.org/10.1007/BF03168623
Issue Date:
DOI: https://doi.org/10.1007/BF03168623