Complete foetal ECG morphology recording by synchronised adaptive filtration

  • Physiological Measurement
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

Present noninvasively measured indices of foetal stress are indirect and not sufficient. Foetal electrocardiography (FECG) is a potential noninvasive measurement of the foetus wellbeing which has been little utilised because of the difficulties of measuring it. The development of time-sequenced adaptive filters which are synchronised to the QRS complex by the use of Doppler echocardiography allowed the recording of relatively noise-free FECG. The paper describes the use of this technique for obtaining the complete complex of the FECG. Several sets of time-sequenced adaptive filters are combined to allow a multilead abdominal recording to produce a measurement system which rejects maternal ECG and enhances the FECG. Five subjects have been analysed, and their FECGs have been accurately reproduced with minimal changes of the filters' parameters.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Bergveld, P., Kolling, A. J. andPeuscher, J. H. J. (1985) Realtime fetal ECG recording.IEEE Trans.,BME-33, 505–508.

    Google Scholar 

  • Creoles, W., Restivo, M., Assadi, M. A. andEl-sherif, N. (1986) Criteria for optimal averaging of cardiac signals.Ibid.,,BME-33, 957–966.

    Google Scholar 

  • Ferrara, E. R. (1977) The time-sequenced adaptive filter. Ph.D. dissertation, Stanford University, California, USA.

    Google Scholar 

  • Ferrara, E. R. andWidrow, B. (1981a) The time-sequenced adaptive filter.IEEE Trans.,ASSP-29, 679–683.

    Article  Google Scholar 

  • Ferrara, E. R. andWidrow, B. (1981b) Multichannel adaptive filter for signal enhancement.Ibid.,,ASSP-29, 766–770.

    MATH  Google Scholar 

  • Ferrara, E. R. andWidrow, B. (1982) Fetal electrocardiogram enhancement by time-sequenced adaptive filtering.Ibid.,,BME-29, 458–460.

    Google Scholar 

  • Goddard, B. A., Newell, J. A., Edwards, R. L. andFarr, R. F. (1966) A clinical foetal electrocardiograph.Med. & Biol. Eng.,4, 159–167.

    Google Scholar 

  • Greene, K. R. (1987) The ECG waveform. Baillieres.Clin. Obstet. Gynaecol.,1, (1), 131–155.

    Google Scholar 

  • Hawrylyshyn, P. A., Bernstein, A. andOrgan, L. W. (1982) Fetal preejection period.Obstet. & Gynecol.,59, 747–754.

    Google Scholar 

  • Jenkins, H. M., Symonds, E. M., Kirk, D. L. andSmith, P. R. (1986) Can fetal electrocardiography improve the prediction of intrapartum fetal acidosis?Br. J. Obstet. Gynaecol.,93, 6–12.

    Google Scholar 

  • Murata, Y. andMartin, C. B. (1977) Systolic time intervals of the fetal cardiac cycle.Postgrad. Med.,61, 127–134.

    Google Scholar 

  • Pan, J. andTompkins, W. J. (1985) A real-time QRS detection algorithm.IEEE Trans.,BME-32, 230–235.

    Google Scholar 

  • Pardi, G., Ferrazzi, E., Cetin, I., Rampello, S., Baselli, G., Cerutti, S. andCivardi, S. (1986) The clinical relevance of the abdominal fetal electrocardiogram.J. Perinat. Med.,14, 371–377.

    Google Scholar 

  • Reichart, T. A., Longini, R. L., Crowley, J. S. andYu, J. M. (1977) A non-invasive extraction of the fetal electrocardiogram.Computers & Biomed. Res.,10, 1–7.

    Article  Google Scholar 

  • Rosen, K. G. (1986) Alterations in the fetal electrocardiogram as a sign of fetal asphyxia-experimental data with a clinical implementation.J. Perinat. Med.,14, 355–363.

    Google Scholar 

  • Saini, V. D. andMaulik, D. (1985) Computerized detection of low-level fetal signals in the maternal abdominal electrocardiogram.Comput. Biol. Med.,15, (2), 81–93.

    Article  Google Scholar 

  • Schuler, G. (1965) The additive fetal electrocardiograph. Dig. 6th Int. Conf. Med. Electron. & Biol. Eng., Tokyo, Japan.

  • Shavit, D. (1987) Correlating fetal Doppler cardiography and ECG. M.Sc. Thesis, Technion-Israel Institute of Technology, Haifa.

    Google Scholar 

  • Takeuchi, Y. andHokaki, M. (1978) An adaptive correlation ratemeter: a new method for Doppler fetal heart rate measurements.Ultrasonics,16/3, 127–137.

    Article  Google Scholar 

  • Tuck, D. L. (1981) Improved Doppler ultrasonic monitoring of foetal heart rate.Med. & Biol. Eng. & Comput.,19, 135–140.

    Article  Google Scholar 

  • Tuck, D. L. (1982) Improvement in Doppler ultrasound human foetal heart rate records by signal correlation.Ibid.,20, 357–360.

    Article  Google Scholar 

  • Vanderschoot, J., Callaerts, D., Sansen, W., Vandewalle, J., Vantrappen, G. andJanssens, J. (1987) Two methods for optimal MECG elimination and FECG detection from skin electrode signals.IEEE Trans.,BME-34, 233–243.

    Google Scholar 

  • van Oosterom, A. (1986) Spatial filtering of the FECG.J. Perinat. Med.,14, 411–419.

    Article  Google Scholar 

  • Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Dong, E. andGoodlin, R. C. (1975) Adaptive noise canceling: principles and application.Proc. IEEE,63, 1692–1716.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Adam, D., Shavit, D. Complete foetal ECG morphology recording by synchronised adaptive filtration. Med. Biol. Eng. Comput. 28, 287–292 (1990). https://doi.org/10.1007/BF02446144

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02446144

Keywords

Navigation