Skip to main content
Log in

When are actively balanced biphasic (‘Lilly’) stimulating pulses necessary in a neurological prosthesis? I Historical background; Pt resting potential;Q studies

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

Actively balanced (‘Lilly’) stimulating current waveforms are generally considered to give very ‘safe’ stimulation. Although this is perfectly true, the specification of the necessary waveform generators in neurological prostheses demands additional complexity, and probably additional expense and development time as well. The paper and its companion enquire whether the use of simple, passively charge-balanced stimulating pulses is equally safe, provided the stimulation parameters and circuitry are designed with appropriate care. It is concluded that, in respect of safe deliverable charge density per pulse at the electrode, release of noxious products and stimulating effectiveness, simple pulses need give no worse performance; in some circumstances they may give better.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Berkley, C. (1965) Potential problems in long term stimulation. Digest of the 6th International Conference on Medical and Biological Engineering, Tokyo.

  • Bockris, J. O'M. andReddy, A. K. N. (1970)Modern electrochemistry. Plenum Press, New York.

    Google Scholar 

  • Bowden, F. P. (1929) The amount of hydrogen and oxygen present on the surface of a metallic electrode.Proc. R. Soc.,125A, 446–462.

    Google Scholar 

  • Brummer, S. B. andTurner, M. J. (1977a) Electrochemical considerations for safe electrical stimulation of the nervous system with platinum electrodes.IEEE Trans.,BME-24, 59–62.

    Google Scholar 

  • Brummer, S. B. andTurner, M. J. (1977b) Electrical stimulation with Pt electrodes I.-—Ibid.,BME-24, 436–439.

    Google Scholar 

  • Brummer, S. B. andTurner, M. J. (1977c) Electrical stimulation with Pt electrodes II.-—Ibid.,BME-24, 440–443.

    Google Scholar 

  • Brummer, S. B., McHardy, J. andTurner, M. J. (1977) Electrical stimulation with Pt electrodes III.Brain Behav. Evol.,14, 10–22.

    Google Scholar 

  • de Boer, R. W. andvan Oosterom, A. (1978) Electrical properties of platinum electrodes: impedance measurements and time-domain analysis.Med. & Biol. Eng. & Comput.,16, 1–10.

    Google Scholar 

  • Donaldson, N. de N. andDonaldson, P. E. K. (1986) When are actively balanced biphasic (‘Lilly’) stimulating pulses necessary in neurological prostheses? II pH changes; noxious products; electrode corrosion; discussion.-—Ibid.,24, 50–56.

    MathSciNet  Google Scholar 

  • Greatbatch, W. (1973) Electrochemical criteria for selection of chronically implanted stimulatory electrodes. InChronically implanted cardiovascular instrumentation.McCutcheon, P. (Ed.), Academic Press, New York, Chap. 19.

    Google Scholar 

  • Hoare, J. P. (1967)Advances in electrochemistry and electrochemical engineering, vol. 6 Delahay, P. (Ed.), Interscience, New York.

    Google Scholar 

  • Lilly, J. C., Austin, G. M. andChambers, W. W. (1952) Threshold movements produced by excitation of cerebral cortex and efferent fibres with some parametric regions of rectangular current pulses.J. Neurophysiol.,15, 319–341.

    Google Scholar 

  • Lilly, J. C., Hughes, J. R., Alvord, E. C. andGalkin, T. W. (1955) Brief non-injurious electric waveforms for stimulation of the brain.Science,121, 468–469.

    Google Scholar 

  • Loeb, J. C., McHardy, J., Kelliher, E. M. andBrummer, S. B. (1982) Neural prostheses. InBiocompatibility in clinical practice, Vol. II Williams, D. F. (Ed.), CRC Press. Chap. 8.

  • McHardy, J., Robblee, L. S., Marston, J. M. andBrummer, S. B. (1980) Electrical stimulation with Pt electrodes IV.Biomaterials,1, 129–134.

    Article  Google Scholar 

  • Onaral, B. andSchwan, H. P. (1982) Linear and nonlinear properties of platinum electrode polarisation. Part 1: frequency dependence at very low frequencies.Med. & Biol. Eng. & Comput.,20, 299–306.

    Article  Google Scholar 

  • Peters, D. G. andLingane, J. J. (1962) Anodic formation and chemical analysis of oxychloride films on platinum electrodes.J. Electroanal. Chem.,4, 193–217.

    Article  Google Scholar 

  • Robblee, L. S., McHardy, J., Marston, J. M. andBrummer, S. B. (1980) Electrical stimulation with Pt electrodes B.Biomaterials,1, 135–139.

    Article  Google Scholar 

  • Robblee, L. S., Lefko, J. L. andBrummer, S. B. (1983) Activated Ir: An electrode suitable for reversible charge injection in saline solution.J. Electrochem. Soc.,130, 731–733.

    Article  Google Scholar 

  • Weinman, J. andMahler, J. (1964) An analysis of electrical properties of metal electrodes.Med. Electron. Biol. Eng.,2, 299–309.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Donaldson, N.d.N., Donaldson, P.E.K. When are actively balanced biphasic (‘Lilly’) stimulating pulses necessary in a neurological prosthesis? I Historical background; Pt resting potential;Q studies. Med. Biol. Eng. Comput. 24, 41–49 (1986). https://doi.org/10.1007/BF02441604

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02441604

Keywords

Navigation