Abstract
A study is made of the correction, in k0-standardized NAA, for interferences caused by fast neutron induced threshold reactions, second order reactions and235U-fission. The following examples are elaborated: determination of the Cr and Sc concentrations in a reference human serum, corrected for the54Fe(n,α)51Cr and44Ca(n,γ;β−; n,γ)46Sc interferences, respectively, and the determination of Zr, Cs, La, Ce, Nd and Sm concentrations in USGS BCR-1 and G-2, corrected for235U(n, f) interference. A detailed uncertainty analysis and a comparison of the analytical results thus obtained with other literature values proves that the interferences can be accurately corrected for by employing the usual neutron flux monitors in the k0-method, namely a Zr-foil and a dilute Au−Al alloyed wire.
Similar content being viewed by others
References
F. DE CORTE, A. SIMONITS, A. DE WISPELAERE, J. HOSTE, J. Radioanal. Nucl. Chem. 113 (1987) 145.
LIN XILEI, D. VAN RENTERGHEM R. CORNELIS, L. MEES, Anal. Chim. Acta 211 (1988) 231.
F. DE CORTE, L. MOENS, S. JOVANOVIC, A. SIMONITS, A. DE WISPELAERE, J. Radioanal. Nucl. Chem., 102 (1986) 37.
F. DE CORTE, A. SIMONITS, J. Radioanal. Nucl. Chem., 133 (1989) 43.
F. DE CORTE, S. JOVANOVIC, A. SIMONITS, L. MOENS, J. HOSTE, Atomkernenergie-Kerntechnik, Suppl. to 44 (1984) 641.
A. SIMONITS, F. DE CORTE, A. DE WISPELAERE, J. HOSTE, J. Radioanal. Nucl. Chem., 113 (1987) 187.
J. W. MÜLLER, Precision Measurements and Fundamental Constants II, B. N. TAYLOR, W. D. PHILLIPS (Eds), Natl. Bureau of Standards, U. S., Spec. Publ. 617, 1984, p. 375.
J. VERSIECK, L. VANBALLENBERGHE, A. DE KESEL, J. HOSTE, B. WALLAEYS, J. VANDENHAUTE, N. BAECK, H. STEYAERT, A. R. BYRNE, F. W. SUNDERMAN, Anal. Chim. Acta, 204 (1988) 63.
J. VERSIECK, J. HOSTE, L. VANBALLENBERGHE, A. DE KESEL, D. VAN RENTERGHEM, J. Radioanal. Nucl. Chem., 113 (1987) 299.
W. MAENHAUT, J. OP DE BEECK, J. Radioanal. Chem., 5 (1970) 115.
J. OP DE BEECK, J. Radioanal. Chem., 3 (1969) 431.
G. V. IYENGAR, W. E. KOLLMER, H. J. M. BOWEN, The Elemental Composition of Human Tissues and Body Fluids, Verlag Chemie, Weinheim, 1978.
LIN XILEI, F. DE CORTE, L. MOENS, A. SIMONITS J. HOSTE, J. Radioanal. Nucl. Chem., 81 (1984) 333.
E. S. GLADNEY, C. E. BURNS I. ROELANDTS, Geostand. Newsl., 7 (1983) 3.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Xilei, L., Van Renterghem, D., De Corte, F. et al. Correction for neutron induced reaction interferences in the NAA k0-standardization method. Journal of Radioanalytical and Nuclear Chemistry, Articles 133, 153–165 (1989). https://doi.org/10.1007/BF02039972
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02039972