Abstract
The use of Digital Subtracton Angiography in coronary applications is restricted by the difficulty in: 1. obtaining a good resolution of the distal branches. 2. avoiding, for the purpose of subtraction, the motion artifacts induced by artery and background displacement during the cardiac and respiratory cycles. 3. preserving the dynamic vascular motion. 4. and storing the digital dynamic information on a permanent support. We used for this study an angiography system, based upon a high resolution 45 MIPS-32 Mbyte image processor, interfaced with a 2.75 Gbyte Winchester drive allowing the real time storage of either 30 frames/s in the 512*512*8 bits matrix or of 7.5 f/s in the 1024*1024*8 bits matrix. To preserve the most important dynamic informations on the basis of the 7.5 f/s maximal storage rate, we developed a synchronization device able to recognize in real time, from chronologic delays derived by using both ECG and Aortic Pressure curves, the functional End-Diastolic (ED) and the End-Systolic (ES) positions, even in the case of heart rates varying during the procedure. The ED and the ES images are stored together with the Mid-Systolic (MS), the 1—Diastolic (1/3D) and 2/3-Diastolic (2/3D) images. To establish the validity of this sampling method, which uses a reduced number of frames per cardiac cycle, 7200 coronary injections performed during 450 routine coronary angiographics were compared by two independent observers (A and B), using: first a Digital (D) 5 frames/cycle sequence, and secondly a cine Film (F) 50 frames/s sequence acquired immediately after the corresponding D injection. The D technique resulted in the best image and diagnostic quality, particularly when the F quality was estimated ‘fair’ or ‘poor’ by both observers, and in an important reduction on X-Ray doses.
The visualisation of the sequential ED, MS, ES, 1/3D and 2/3D frames gives the possibility: 1. of saving the dynamic information, as a regular sample offunctional images, can be displayed with a cine loop technique. 2. of facilitating cardiac synchronized subtractions. 3. of reducing the amount of frames per cycle, thus allowing an important reduction of X-ray doses and the digital and permanent storage of the most important cardiac cycles.
Similar content being viewed by others
References
Riederer SJ, Kruger RA. Intravenous digital subtraction: a summary of recent developments. Radiology 1983; 147: 633–38.
Enzmann Dr, Djang WT, Riederer SJ. Low-dose, highframe-rate versus regular-dose, low-frame-rate digital subtraction angiography. Radiology 1983; 146: 669–76.
Ergun DL, Shaw CG, Kruger RA, Mistretta CA, Zarnstorf WC. Video slow scan technique for mask mode subtraction radiography. In: Annual meeting of the radiological Society of North America; 1980 Nov; Dallas.
Azancot I, Kedra AW, Melki JP, Soulez G, Favreau X, Azancot S, et al. Digital pulmonary angiography: a synchronization procedure for anatomical and functional image optimization. Cardio Imag 1989; 1: 30–359.
Azancot I, Kedra A, Friolo S, Mallergue C, Nittemberg A, Bourthoumieux A, et al. Contibution of digital processing for Left Ventricular and Coronary evaluation. Cardiologia 1988; 33: 563–70.
Hirji M, Gamsu G, Webb WR, Brito AC, Kuriyama K, Stern RG, et al. ECG gated digital subtraction angiography in the detection of pulmonary emboli. Radiology 1984; 152: 19–23.
Vogel R, Lefree M, Bates E, O'Neill W, Foster R, Kirlin Ph, et al. Application of digital techniques to selective coronary arteriography: use of myocardial contrast appearance time to measure coronary flow reserve. Am Heart J 1984; 107: 153–1644.
Levin DC, Schapiro RM, Boxt LM, Dunam L, Harrington DP, Ergun DL. Digital subtraction angiography: principles and pitfails of image improvement techniques. Am J Radiol 1984; 143: 447–4514.
Popma JJ, Eichhorn EJ, Dehmer GJ.In vivo assessment of Digital Angiographic method to measure absolute coronary artery diameters. Am J Cardiol 1989: 64: 131–1389.
Nissen SE, Elion JL, Booth DG, Evans J, de Maria AN. Value and limitations of computer analysis of digital subtraction angiography in the assessment of coronary flow reserve. Circulation 1986; 73: 562–5696.
Favereau X, Corcos T, Souffrant G. Efficacy and safety of ambulatory coronary angiographics. Arch Mal Coeur 1990; 83: 191–1950.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Azancot, I., Eiferman, C., Le Dref, O. et al. Improvement of digital coronary angiography: high resolution processing coupled with a real time functional synchronization procedure. Int J Cardiac Imag 8, 109–119 (1992). https://doi.org/10.1007/BF01137532
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF01137532