Abstract
We investigated the renal clearance, the extrarenal clearance, the biodistribution, the plasma extraction ratio and the imaging quality on a scintillation camera of a new substance: 99mTc-mercaptoacetyltriglycine (MAG-3) in rats. Simultaneously 125I-hipputate (OIH) and 51Cr-EDTA were used as reference substances. In scintillation camera studies, 123I-hippurate served as reference. MAG-3 was prepared by kit labelling without further purification, as it would be used in clinical studies. However in three separate rats, HPLC purified MAG-3 was used. High renal clearance and extraction ratio was found but these were less than that for OIH (1.95 ml/min per 100 g BW vs 2.76 ml/min per 100 gBW and 64% vs 85% respectively). The extrarenal clearance was higher for MAG-3 than for OIH (0.20 ml/min per 100 g BW vs 0.04 ml/min per 100 g BW), presumably because of bile excretion. HPLC purification increased the renal excretion of MAG-3: the clearance was 2.53 ml/min per 100 g BW, the extraction fraction 75%, but the extrarenal clearance was unchanged. The imaging quality was comparable to that of 123I-hippurate in early pictures, but extrarenal activity, presumably representing bile, was observed in late pictures. We conclude that MAG-3 has some potential for the replacement of OIH but clinical studies are necessary to test whether the same conditions and limitations exist in humans.
Similar content being viewed by others
References
Botsch H, Sörensen R, Schwarz G (1975) Studies on the extraction ratio of labelled o-iodohippurate in man with regard to radioactivity in plasma and red blood cells. In: Zum Winkel K, Blaufox D, Funck-Brentano JL, (eds) Radionuclides in Nephrology Proceedings of the IIIrd International Symposium Berlin, April 1974. Georg Thieme, Stuttgart, pp 222–225
Fritzberg AR, Klingensmith WC, Whitney WP, Kuni CC (1981) Chemical and biological studies of N,N′-bis (Mercaptoacetamido) ethylenediamine: A potential replacement for I-131 iodohippurate. J Nucl Med 22:258–263
Fritzberg AR, Kuni CC, Klingensmith WC, Stevens J, Whitney WP (1982) Synthesis and biological evaluation of Tc-99m N,N′-bil(mercaptoacetyl)-2,3-diaminiopropanoate: A potential replacement of 131-I o-iodohippurate. J Nucl Med 23:592–598
Fritzberg AR, Kasina S, Eshima D, Johnson DL (1986) Synthesis and biological evaluation of technetium-99m MAG-3 as a hippuran replacement. J Nucl Med 27:111–116
Hermansson K, Larson M, Källskog Ö, Wolgast M (1981) Influence of renal nerve activity on arteriolar resistance, ultrafiltration dynamics and fluid reabsorption. Pflügers Arch 389:85–90
Klingensmith WC, Gerhold JP, Fritzberg AR, Spitzer VM, Kuni CC, Singer CJ, Weil R (1982) Clinical comparison of N,N′-bis(mercaptoacetamido)ethylenediamine and I-131 orthoiodohippurate for evaluation of renal tubular function: concise communication. J Nucl Med 23:377–380
Klingensmith WC, Fritzberg AR, Spitzer VM, Johnson DL, Kuni CC, Williamson MR, Waser G, Weil R (1984) Clinical evaluation of Tc-99m N,N′-bil(mercaptoacetyl)-2.3-diaminopropanoate as a replacement for I-131 hippurate: concise communication. J Nucl Med 25:42–48
Standalnik RC, Vogel JM, Jansholt AL, Krohn KA, Matolo NM, Lagunas-Solar MC, Zielinski FW (1980) Renal clearance and extraction parameters of ortho-iodohippurate (I-123) compared with OIH (I-131) and PAH. J Nucl Med 21:168–170
Taylor A, Ishima D, Fritzberg AR, Christina PE, Kasina S, Milton W, Datz DL (1985) Evaluation of Tc-99m mercaptoacetyl-triglycine as a potential replacement for I-131 hippurate in human subjects. J Nucl Med 26:57
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Müller-Suur, R., Müller-Suur, C. Renal and extrarenal handling of a new imaging compound (99m-Tc-MAG-3) in the rat. Eur J Nucl Med 12, 438–442 (1986). https://doi.org/10.1007/BF00254747
Received:
Accepted:
Published:
Issue Date: