Skip to main content
Log in

Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting

  • Clinical Investigation
  • Published:
CardioVascular and Interventional Radiology Aims and scope Submit manuscript

Abstract

Introduction

Computed tomography (CT) fluoroscopy-guided renal cryoablation and lung radiofrequency ablation (RFA) have received increasing attention as promising cancer therapies. Although radiation exposure of interventional radiologists during these procedures is an important concern, data on operator exposure are lacking.

Materials and Methods

Radiation dose to interventional radiologists during CT fluoroscopy-guided renal cryoablation (n = 20) and lung RFA (n = 20) was measured prospectively in a clinical setting. Effective dose to the operator was calculated from the 1-cm dose equivalent measured on the neck outside the lead apron, and on the left chest inside the lead apron, using electronic dosimeters. Equivalent dose to the operator’s finger skin was measured using thermoluminescent dosimeter rings.

Results

The mean (median) effective dose to the operator per procedure was 6.05 (4.52) μSv during renal cryoablation and 0.74 (0.55) μSv during lung RFA. The mean (median) equivalent dose to the operator’s finger skin per procedure was 2.1 (2.1) mSv during renal cryoablation, and 0.3 (0.3) mSv during lung RFA.

Conclusion

Radiation dose to interventional radiologists during renal cryoablation and lung RFA were at an acceptable level, and in line with recommended dose limits for occupational radiation exposure.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. de Mey J, Op de Beeck B, Meysman M, Noppen M, De Maeseneer M, Vanhoey M, et al. Real time CT-fluoroscopy: diagnostic and therapeutic applications. Eur J Radiol. 2000;34(1):32–40.

    Article  PubMed  Google Scholar 

  2. Daly B, Krebs TL, Wong-You-Cheong JJ, Wang SS. Percutaneous abdominal and pelvic interventional procedures using CT fluoroscopy guidance. AJR Am J Roentgenol. 1999;173(3):637–44.

    Article  CAS  PubMed  Google Scholar 

  3. Paulson EK, Sheafor DH, Enterline DS, McAdams HP, Yoshizumi TT. CT fluoroscopy-guided interventional procedures: techniques and radiation dose to radiologists. Radiology. 2001;220(1):161–7.

    Article  CAS  PubMed  Google Scholar 

  4. Teeuwisse WM, Geleijns J, Broerse JJ, Obermann WR, van Persijn van Meerten EL. Patient and staff dose during CT guided biopsy, drainage and coagulation. Br J Radiol. 2001;74(884):720–6.

    Article  CAS  PubMed  Google Scholar 

  5. Irie T, Kajitani M, Itai Y. CT fluoroscopy-guided intervention: marked reduction of scattered radiation dose to the physician’s hand by use of a lead plate and an improved I-I device. J Vasc Interv Radiol. 2001;12(12):1417–21.

    Article  CAS  PubMed  Google Scholar 

  6. Buls N, Pages J, de Mey J, Osteaux M. Evaluation of patient and staff doses during various CT fluoroscopy guided interventions. Health Phys. 2003;85(2):165–73.

    Article  CAS  PubMed  Google Scholar 

  7. Saidatul A, Azlan C, Megat AM, Abdullah B, Ng K. A survey of radiation dose to patients and operators during radiofrequency ablation using computed tomography. Biomed Imaging Interv J. 2010;6(1):e1.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  8. Kim GR, Hur J, Lee SM, Lee HJ, Hong YJ, Nam JE, et al. CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance. Eur Radiol. 2011;21(2):232–9.

    Article  PubMed  Google Scholar 

  9. McEachen JC, Leng S, Atwell TD, Tollefson MK, Friese JL, Wang Z, et al. Percutaneous renal tumor ablation: radiation exposure during cryoablation and radiofrequency ablation. Cardiovasc Intervent Radiol. 2016;39(2):233–8.

    Article  PubMed  Google Scholar 

  10. Tracy CR, Kogan P, Gupta A, Gahan JC, Theckumparampil N, Elsamra SE, et al. Radiation exposure during percutaneous ablation of small renal masses: a multi-institutional, multi-modality analysis. J Endourol. 2015;29(11):1314–20.

    Article  PubMed  Google Scholar 

  11. Arnold DC 2nd, Schroeder G, Smith JC, Wahjudi IN, Heldt JP, Richards GD, et al. Comparing radiation exposure between ablative therapies for small renal masses. J Endourol. 2013;27(12):1435–9.

    Article  PubMed  Google Scholar 

  12. Stewart JK, Looney CB, Anderson-Evans CD, Toncheva GI, Sopko DR, Kim CY, et al. Percutaneous cryoablation of renal masses under CT fluoroscopy: radiation doses to the patient and interventionalist. Abdom Imaging. 2015;40(7):2606–12.

    Article  PubMed  Google Scholar 

  13. Kloeckner R, dos Santos DP, Schneider J, Kara L, Dueber C, Pitton MB. Radiation exposure in CT-guided interventions. Eur J Radiol. 2013;82(12):2253–7.

    Article  PubMed  Google Scholar 

  14. Bodily KD, Atwell TD, Mandrekar JN, Farrell MA, Callstrom MR, Schmit GD, et al. Hydrodisplacement in the percutaneous cryoablation of 50 renal tumors. AJR Am J Roentgenol. 2010;194(3):779–83.

    Article  PubMed  Google Scholar 

  15. Hiraki T, Gobara H, Shibamoto K, Mimura H, Soda Y, Uka M, et al. Technique for creation of artificial pneumothorax for pain relief during radiofrequency ablation of peripheral lung tumors: report of seven cases. J Vasc Interv Radiol. 2011;22(4):503–6.

    Article  PubMed  Google Scholar 

  16. Hiraki T, Gobara H, Iguchi T, Fujiwara H, Matsui Y, Kanazawa S. Creation of an artificial hydromediastinum for radiofrequency ablation of lung tumor: a report of two cases. J Vasc Interv Radiol. 2014;25(11):1834–7.

    Article  Google Scholar 

  17. International Commission on Radiological Protection. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP, 103. Ann ICRP. 2007;37(2–4):1–332.

  18. Komemushi A, Tanigawa N, Kariya S, Kojima H, Shomura Y, Sawada S. Radiation exposure to operators during vertebroplasty. J Vasc Interv Radiol. 2005;16(10):1327–32.

    Article  PubMed  Google Scholar 

  19. Funao H, Ishii K, Momoshima S, Iwanami A, Hosogane N, Watanabe K, et al. Surgeons’ exposure to radiation in single- and multi-level minimally invasive transforaminal lumbar interbody fusion; a prospective study. PLoS One. 2014;9(4):e95233.

    Article  PubMed  PubMed Central  Google Scholar 

  20. Kato R, Katada K, Anno H, Suzuki S, Ida Y, Koga S. Radiation dosimetry at CT fluoroscopy: physician’s hand dose and development of needle holders. Radiology. 1996;201(2):576–8.

    Article  CAS  PubMed  Google Scholar 

  21. Daly B, Frita SL, Templeton PA, Krebs TL, Wong-You-Cheong JJ. Operator radiation dose utilizing needle guide systems for percutaneous interventional procedures under continuous imaging CT guidance. AJR Am J Roentgenol. 1997;168(suppl):143–4.

    Google Scholar 

  22. Nawfel RD, Judy PF, Silverman SG, Hooton S, Tuncali K, Adams DF. Patient and personnel exposure during CT fluoroscopy-guided interventional procedures. Radiology. 2000;216(1):180–4.

    Article  CAS  PubMed  Google Scholar 

  23. Nickoloff EL, Khandji A, Dutta A. Radiation doses during CT fluoroscopy. Health Phys. 2000;79(6):675–81.

    Article  CAS  PubMed  Google Scholar 

  24. Silverman SG, Tuncali K, Adams DF, Nawfel RD, Zou KH, Judy PF. CT fluoroscopy-guided abdominal interventions: techniques, results, and radiation exposure. Radiology. 1999;212(3):673–81.

    Article  CAS  PubMed  Google Scholar 

  25. Neeman Z, Dromi SA, Sarin S, Wood BJ. CT fluoroscopy shielding: decreases in scattered radiation for the patient and operator. J Vasc Interv Radiol. 2006;17(12):1999–2004.

    Article  PubMed  PubMed Central  Google Scholar 

  26. Solomon SB, Patriciu A, Bohlman ME, Kavoussi LR, Stoianovici D. Robotically driven interventions: a method of using CT fluoroscopy without radiation exposure to the physician. Radiology. 2002;225(1):277–82.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Takao Hiraki.

Ethics declarations

Conflict of Interest

Radiation measurement service with TLD rings was provided free of charge for this study by Nagase Landauer, LTD.

Ethics Approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee, and with the 1964 Helsinki Declaration and its later amendments, or comparable ethical standards.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Matsui, Y., Hiraki, T., Gobara, H. et al. Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting. Cardiovasc Intervent Radiol 39, 894–901 (2016). https://doi.org/10.1007/s00270-016-1308-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00270-016-1308-3

Keywords

Navigation