Dual energy radiography (DER): A preliminary comparative study

  • Rapid Communication
  • Published:
Calcified Tissue International Aims and scope Submit manuscript

Summary

Dual energy radiography (DER) has been recently proposed as a new technique for the non invasive measurement of vertebral mineral density. This preliminary study was undertaken to assess the short-term precision of DER and to compare DER to dual photon absorptiometry (DPA) measurements. Three DER measurements were obtained in 19 healthy volunteers (mean age 34.7 ±9.3 years) over a 3 week period. In addition, both DER and DPA measurements were obtained in 52 women (mean age 54.3±12.5 years). The coefficient of variation for the DER measurements was 1.00%. A highly significant correlation (r=0.94; p<0.0001) was found between DPA and DER. Using this curve a conversion factor of −6.8% was calculated to convert DER to DPA values. Both DER and DPA were significantly and similarly correlated with age (r=−0.43, p<0.005; r=−0.38, p<0.05, respectively). The rates of bone loss, 0.66% per year for DER and 0.57% per year for DPA, were also similar with the two techniques. From these data, it is concluded that DER is a precise new method for vertebral bone mass measurements.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. Genant H.K., Steiger, P., Block, J.E., et al: Quantitative Computed Tomography: Update 1987. Calcif. Tiss. Int.41:179–180, 1987.

    Article  CAS  Google Scholar 

  2. Wilson, C.R., Madsen, M.: Dichromatic absorptiometry of vertebral bone mineral content. Invest. Radiol.12:180–184, 1977.

    Article  PubMed  CAS  Google Scholar 

  3. Madsen, M., Peppler, W., Mazess, R.B.: Vertebral and total body bone mineral content by dual photon absorptiometry. Calcif. Tiss. Res.2:361–364, 1976.

    Google Scholar 

  4. Cann, C.E.: Low-dose CT scanning for quantitative spinal mineral analysis. Radiology160:469–478.

  5. Hanson, J.A., Mazess, R.B., Barden, H.: Influence of source activity on dual-photon scans. J. Bone Min. Res.1:281 (abstract).

  6. Stein, J.A., Hochberg, A.M., Lazewatsky, J.L.: Quantitative Digital Radiography For Bone Mineral Analysis. Presented at The 2nd International Workshop on Bone Measurements: Methodological Problems, Leuven, Belgium, September 25, 1987.

  7. Sartoris, D.J., Resnick, D.: Digital radiography may spark renewal of bone densitometry. Diagnostic Imaging, January, 1988, 145–150.

  8. Peppler, W.W., Mazess, R.B.: Total Body Bone Mineral and Lean Body Mass By Dual Photon Absorptiometry Theory and Measurement Procedure. Calcif. Tiss. Int.33:353, 1981.

    Article  CAS  Google Scholar 

  9. Ott, S.M., Kilcoyne, R.F., Chesnut, C.H.: Longitudinal Changes in Bone Mass After One Year As Measured By Different Techniques in Patients With Osteoporosis. Calcif. Tiss. Int.39:133, 1986.

    Article  CAS  Google Scholar 

  10. Cann, C.L., Genant, H.K., Boyd, D.P., Kolb, F.O., Ettiner, B.: Quantitative Computed Tomography For Prediction of Vertebral Fracture Risk. Bone6:1–7, 1985.

    Article  PubMed  CAS  Google Scholar 

  11. Rosenthal, D., Ganott, M., Wyshak, G., Slovik, D.M., Spooelt, S.H., Neer, R.M.: Quantitative Computed Tomography For Spinal Density Measurements—Factors Affecting Precision. Inter Med.20:306–310, 1982.

    Google Scholar 

  12. Riggs, B.L., Wahner, H.W., Seeman, K.P., et al: Changes in Bone Mineral Density of the Femur and Spine With Aging. J. Clin. Invest.70:716–723, 1982.

    Article  PubMed  CAS  Google Scholar 

  13. Wahner, H.W., Dunn, W.L., Mazess, R.B., et al: Dual-Photon Gd-153 Absorptiometry of Bone. Radiology156:203–206, 1985.

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pacifici, R., Rupich, R., Vered, I. et al. Dual energy radiography (DER): A preliminary comparative study. Calcif Tissue Int 43, 189–191 (1988). https://doi.org/10.1007/BF02571319

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02571319

Keywords

Navigation