A new portable instrument equipped with a microprocessor was designed for the long-term ambulatory monitoring of indirect arterial pressure in the human finger at desired intervals using a volume-oscillometric technique. All the necessary procedures such as (1) programmed control of cuff pressure, (2) detection of the systolic end-point and the point of maximum amplitude of arterial volume pulsations, (3) reading of the cuff pressures corresponding to these two points, (4) its processing and (5) recording of the systolic and mean pressure together with heart rate on a digital memory integrated circuit were performed automatically. After the monitoring, the data were reproduced and analysed by a conventional personal computer. Simultaneous comparison of the data with direct measurement, operation and evaluation of this instrument, and ambulatory monitoring were carried out. With this instrument noninvasive and accurate monitoring of arterial pressure could be made in unrestricted subjects during daily activities.
Similar content being viewed by others
References
Bachmann, K. andKimmich, H. P. (1981) (Eds.) Ambulatory monitoring of blood pressure. InBiotelemetry Patient Monitoring,8, 1–120.
Geddes, L. A. (1970)The direct and indirect measurement of blood pressure. Year Book Medical Publishers, Chicago, 196.
Hinman, A. T., Engel, B. T. andBickford, A. F. (1962) Portable blood pressure recorder: accuracy and preliminary use in evaluating intradaily variations in pressure.Am. Heart J.,63, 663–668.
Ramsey, M. III (1979) Noninvasive automatic determination of mean arterial pressure.Med. & Biol. Eng. & Comput.,17, 11–18.
Schneider, R. A. (1968) A full automatic portable blood pressure recorder.J. Appl. Physiol.,24, 115–118.
Schneider, R. A., Kimmell, G. O. andvan Meter, R. P. Jr. (1974) An improved fully automatic portable blood pressure recorder.—Ibid.,37, 776–779.
Yamakoshi, K., Shimazu, H. andTogawa, T. (1980) Indirect measurement of instantaneous arterial blood pressure in the human finger by the vascular unloading technique.IEEE Trans.,BME-27, 150–155.
Yamakoshi, K., Shimazu, H., Shibata, M. andKamiya, A. (1982a) New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part I: model experiment.Med. & Biol. Eng. & Comput.,20, 307–313.
Yamakoshi, K., Shimazu, H., Shibata, M. andKamiya, A. (1982b) New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 2: correlation study.—Ibid.,20, 314–318.
Yamakoshi, K., Kamiya, A., Shimazu, H., Ito, H. andTogawa, T. (1983) Noninvasive automatic monitoring of instantaneous arterial blood pressure using the vascular unloading technique. —Ibid.,21, 557–565.
Yelderman, M. andReam, A. (1979) Indirect measurement of mean blood pressure in the anesthetized patient.Anesthesiol.,50, 253–256.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Yamakoshi, K., Kawarada, A., Kamiya, A. et al. Long-term ambulatory monitoring of indirect arterial blood pressure using a volume-oscillometric method. Med. Biol. Eng. Comput. 23, 459–465 (1985). https://doi.org/10.1007/BF02448934
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02448934