Skip to main content
Log in

Consideration of measurement error when using commercial indoor radon determinations for selecting radon action levels

  • Radium and Radon Measurement
  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

An examination of year-long, in-home radon measurement in Colorado from commercial companies applying typical methods indicates that considerable variation in precision exsts. This variation can have a substantial impact on any mitigation decisions, either voluntary or mandated by law, especially regarding property sale or exchange. Both long-term exposure (nuclear track greater than 90 days), and short-term (charcoal adsorption 4–7 days) exposure methods were used. In addition, periods of continuous monitoring with a highly calibrated alpha-scintillometer took place for accuracy calibration. The results of duplicate commercial analysis show that typical results are no better than ±25 percent with occasional outliers (up to 5 percent of all analyses) well beyond that limit. Differential seasonal measurements (winter/summer) by short-term methods provide equivalent information to single long-term measurements. Action levels in the U.S. for possible mitigation decisions should be selected so that they consider the measurement variability; specifically, they should reflect a concentration range similar to that adopted by the European Community.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. A. V. Nero, M. B. Schwehr, W. W. Nazaroff, K. L. Revzan, Science, 234 (1986) 992.

    CAS  Google Scholar 

  2. G. M. Reimer, S. L. Szarzi, J. M. Been, U.S. Geological Survey Open File Report 92-391 (1992) 7.

    Google Scholar 

  3. S. B. White, J. W. Bergsten, B. V. Alexander, N. F. Rodman, J. L. Phillips, Health Phys., 62 (1992), 41.

    CAS  Google Scholar 

  4. M. Ronca-Battista, P. Magno, P. C. Nyberg, Health Phys., 55 (1985) 67.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Reimer, G.M., Szarzi, S.L. & Dolan, M.P. Consideration of measurement error when using commercial indoor radon determinations for selecting radon action levels. J Radioanal Nucl Chem 236, 243–245 (1998). https://doi.org/10.1007/BF02386350

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02386350

Keywords

Navigation