References
Berkowitz D (1979) Potential uses of bacteria in toxicology. Vet Hum Toxicol 21: 422–426
Bitton G (1983) Bacterial and biochemical tests for assessing chemical toxicity on the aquatic environment: a review. CRC Crit Rev Environ Control 13: 51–67
Bringmann G, Kuhn R (1980) Comparisons of the toxicity thresholds of water pollutants to bacteria, algae and protozoa in the cell multiplication inhibition tests. Water Res 14: 231–241
Bulich AA (1982) A practical and reliable method for monitoring the toxicity of aquatic samples. Proc Biochem 17: 45–47
Bulich AA, Isenberg DL (1980) Use of the luminescent bacterial system for the rapid assessment of aquatic toxicity. Adv Instrum 80: 35–40
Cairns Jr J, Dickson KL, Westlake GC (eds) (1976) Biological monitoring of water and effluent quality. ASTM STP 607. Amer Soc for Test Mat, Philadelphia, 246 pp
Chang, JC, Taylor PB, Leach FR (1981) Use of the Microtox assay system for environmental samples. Bull Environ Contam Toxicol 26: 150–156
Curtis C, Lima A, Lozano SJ, Veith GD (1982) Evaluation of a bacterial bioluminescence bioassay as a method for predicting acute toxicity of organic chemicals to fish. In: Pearson JG, Foster RB, Bishop WE (eds) Aquatic toxicology and hazard assessment, ASTM STP 766. Amer Soc Test Mat, Philadelphia, pp 170–178
Delistraty D (1984) Bioluminescent toxicity assay of synfuel by-product waters. Bull Environ Contam Toxicol 32: 613–620
Dutka BJ, Kwan KK (1981) Comparison of three microbial toxicity screening tests with the microtox test. Bull Environ Contam Toxicol 27: 753–757
Dutka BJ, Nyholm N, Petersen J (1983) Comparison of several microbiological toxicity screening tests. Water Res 17: 1363–1368
Goatcher LA, Qureshi AA, Gaudet ID (1984) Evaluation and refinement of theSpirillum volutans test for use in toxicity screening. In: Liu D, Dutka BJ (eds) Toxicity screening procedures using bacterial systems. Marcel Dekker, New York, pp 89–108
Lesback ME, Anderson AD, DeGraeve GM, Bergrman AL (1981) Comparison of bacterial luminescence and fish bioassay results for fossil fuel process waters and phenolic constitutents. In: Branson DR, Dickson KL (eds) Aquatic toxicology and hazard assessment, ASTM STP 737. Amer Soc Test Mat, Philadelphia, pp 348–356
Liu D, Dutka BJ (eds) (1984) Toxicity screening procedures using bacterial systems. Marcel Dekker, New York, 476 pp
Little LW (1978) Bioassays — procedures and results. J Water Poll Control Fed 50: 1852–1868
Maciorowski AF, Sims JL, Little LW, Gerrard ED (1981) Bioassays — procedures and results. J Water Poll Control Fed 56: 974–993
McFeters GA, Bond PJ, Olson SB (1983) A Comparison of Microbial bioassays for the detection of aquatic toxicants. Water Res 17: 1757–1762
Qureshi AA, Flood KW, Thompson SR, Janhurst SM, Inniss CS, Rokosh DA (1982) Comparison of a luminescent bacterial test with other bioassays for determining toxicity of pure compounds and complex effluents. In: Pearson JG, Foster RB, Bishop WE (eds) Aquatic toxicology and hazard assessment, ASTM STP 766. Amer Soc Test Mat, Philadelphia, pp 179–195
Qureshi AA, Coleman RN, Paran JH (1984) Evaluation and refinement of the microtox test for use in toxicity screening. In: Liu D, Dutka BJ (eds) Toxicity screening procedures using bacterial systems. Marcel Dekker, New York, pp 1–22
US EPA (1981) Comparison of the response of Microtox, fish, and invertebrates to effluent toxicity. EPA Quality Assurance Newsletter 4(2):2–3.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Coleman, R.N., Qureshi, A.A. Microtox® andSpirillum volutans tests for assessing toxicity of environmental samples. Bull. Environ. Contam. Toxicol. 35, 443–451 (1985). https://doi.org/10.1007/BF01636536
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF01636536