In the management of shunt infection, the use of ventricular catheters made of silicone rubber for the temporary external drainage of cerebrospinal fluid (CSF) is general practice. However, the eradication of the primary source of infection may be hindered by the affinity of bacteria to silicone-based material. Compared to silicone catheters, a metal drainage device for temporary ventriculostomy appears to offer more favourable conditions for successful eradication of the infection. Since metal needles cannot be implanted permanently and since their screw-type fixation precludes attachment to the skulls of infants or small children, we developed a flexible metal catheter. This catheter was used exclusively for the treatment of particularly serious or chronic infections of the CSF spaces. The catheter is made of implantation steel and consists of a corrugated tube that renders it flexible. Cerebrospinal fluid drains into a receptable bulb at the tip of the tube. Tubing of other materials may be connected to the end of the metal catheter for either external or internal drainage. It was implanted as a temporary and later permanent CSF drainage in 7 male patients aged from 4 to 60 years, who suffered from chronic, recurrent ventriculitis (n = 5) with an average of 7 previous surgical revisions, as well as from complex infections (n = 2; basal tuberculous meningitis, brain abscess). The infections were successfully eliminated in 6 patients. In the remaining patient, the metal catheter for external ventriculostomy had to be removed after 4 days due a leakage of CSF; it was replaced by a silicone catheter and later on by a needle drainage. Other complications, such as secondary infection or intracerebral haemorrhage, did not occur. The average duration of external CSF drainage via the flexible metal catheter was 27 days (range 4–50 days). In 4 patients, the CSF drainage was converted to a permanent ventriculoperitoneal shunt using a new flexible metal catheter. At the time of post-operative follow-up examination (average = 34 weeks), all shunts were functioning and there was no evidence of infection. In cases of especially complicated and protracted CSF infections, the flexible metal ventricular catheter is a promising device for treatment.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Bayston R, Rodgers J (1990) Production of extra-cellular slime by Staphylococcus epidermidis during stationary phase of growth: its association with adherence to implantable devices. J Clin Pathol 43: 866–870

    PubMed  Google Scholar 

  2. Bayston R, Lari J (1974) A study of the sources of infection in colonised shunts. Dev Med Child Neurol 16 [Suppl 32]: 16–22

    PubMed  Google Scholar 

  3. Booth LV, Palmer JD, Pateman J, Tuck AC (1993) Citrobacter diversus ventriculitis and brain abscesses in an adult. J Infect 26: 207–209

    PubMed  Google Scholar 

  4. Chan KH, Mann KS (1988) Prolonged therapeutic external ventricular drainage: a prospective study. Neurosurg 23: 436–438

    Google Scholar 

  5. Chaparro MJ, Pritz MB, Yonemura KS (1991/1992) Broviac ventriculostomy for long-term external ventricular drainage. Pediatr Neurosurg 17: 208–212

    Google Scholar 

  6. Friedman WA, Vries JK (1980) Percutaneous tunnel ventriculostomy: summary of 100 procedures. J Neurosurg 53: 662–665

    PubMed  Google Scholar 

  7. Gilsbach J, Schumacher M (1978) Diagnostischer und therapeutischer Wert der perkutanen Nadeltrepanation. Neurochirurgia 21: 128–131

    PubMed  Google Scholar 

  8. Hassler W, Zentner J (1988) Ventricular puncture for external CSF drainage and pressure measurement using a modified puncture needle. Acta Neurochir (Wien) 94: 93–95

    Google Scholar 

  9. Jansen B, Peters G, Pulverer G (1988) Mechanisms and clinical relevance of bacterial adhesion to polymers. J Biomat Appl 2: 520–542

    Google Scholar 

  10. Khanna RK, Rosenblum ML, Rock JP, Malik GM (1995) Prolonged external ventricular drainage with percutaneous longtunnel ventriculostomies. J Neurosurg 83: 791–794

    PubMed  Google Scholar 

  11. Mapstone TB, Ratcheson RA (1985) Techniques of ventricular puncture. In: Wilkins RH, Rengachary SS (eds) Neurosurgery, Vol 1. MacGraw-Hill, New York, pp 151–155

    Google Scholar 

  12. Mayhall CG, Archer NH, Lamb VA, Spadora AC, Baggett JW, Ward JD, Narayan RK (1984) Ventriculostomy-related infections — a prospective epidemiologic study. N Engl J Med 310: 553–559

    PubMed  Google Scholar 

  13. Meyer B, Schaller K, Rohde V, Hassler W (1994) Percutaneous needle trephination. Experience in 200 cases. Acta Neurochir (Wien) 127: 232–235

    Google Scholar 

  14. Peters G (1988) New consideration on the pathogenesis of coagulase-negative staphylococcal foreign body infections. J Antimicrob Chemother 21 [Suppl C]: 139–148

    PubMed  Google Scholar 

  15. Petty W, Spanier S, Shuster JJ, Silverthorne C 1985) The influence of skeletal implants on incidence of infection. Experiments in a canine model. J Bone Joint Surg (Am) 67: 1236–1244

    Google Scholar 

  16. Rappaport ZH, Shalit MN (1988) Perioperative external ventricular drainage in obstructive hydrocephalus secondary to infratentorial brain tumours. Acta Neurochir (Wien) 96: 118–121

    Google Scholar 

  17. Rotta AT, Asmar BI, Ballal N, Canady A (1995) Moraxella catarrhalis ventriculitis in a child with hydrocephalus and external ventricular drain. Pediatr Infect Dis J 14: 397–398

    PubMed  Google Scholar 

  18. Scarff TB, Nelson PBX, Reigel DH (1978) External drainage following cerebrospinal fluid shunts. Child Brain 4: 129–136

    Google Scholar 

  19. Schoenbaum SC, Gardner P, Shillito J (1975) Infections of cerebrospinal fluid shunts. Epidemiology, clinical manifestations and therapy. J Infect Dis 131: 543–552

    PubMed  Google Scholar 

  20. Schwarz A, Langmayr JJ, Ortler M, Fille M (1993) Aktinomykose-Infektion im Kleinhirn. Wien Klin Wochenschr 105: 359–361

    PubMed  Google Scholar 

  21. Shalit MN, Ben Ari Y, Eynan N (1979) The management of obstructive hydrocephalus by the use of external continuous ventricular drainage. Acta Neurochir (Wien) 47: 161–172

    Google Scholar 

  22. Smith RW, Alksne JF (1976) Infections complicating the use of external ventriculostomy. J Neurosurg 44: 567–570

    PubMed  Google Scholar 

  23. Tronnier V, Aschoff A, Hund E, Hampl J, Kunze S (1991) Commercial external ventricular drainage sets: unsolved safety and handling problems. Acta Neurochir (Wien) 110: 49–56

    Google Scholar 

  24. Witzenmann H (1885) Deutsches Reichspatent Nr. 34871

  25. Wyler AR, Kelly WA (1972) Use of antibiotics with external ventriculostomies. J Neurosurg 37: 185–187

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Vieweg, U., Kaden, B. & Van Roost, D. A flexible metal ventricular catheter for treatment of complicated and protracted infections of the cerebrospinal fluid spaces: Preliminary experiences. Acta neurochir 138, 1431–1436 (1996). https://doi.org/10.1007/BF01411122

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01411122

Keywords

Navigation