Summary
The endexpiratory lung volume was measured at various levels of minute ventilation during exercise by the nitrogen wash-out method in 22 healthy young subjects. Tidal volume increases only from the inspiratory reserve volume until it reaches the value of 40% of the vital capacity. There is no shift of the endexpiratory position. With a tidal volume larger than 40% of the vital capacity the endexpiratory lung volume decreases, which means that the tidal volume has even increased at the expense of the expiratory reserve volume. No differences were found between men and women providing that all values are expressed as a percentage of the total lung capacity.
Similar content being viewed by others
References
Agostoni, E., andJ. Mead: Statics of the respiratory system. In: Handbook of Physiology. Respiration, p. 387, sect. 3, vol.1, chapt. 13, Washington D. C., Amer. Physiol. Soc. 1965.
Asmussen, E., u.E. H. Christensen: Die Mittelkapazität der Lungen bei erhöhtem O2-Bedarf. Skand. Arch. Physiol.82, 201 (1939).
Darling, R. C., A. Cournand, andD. W. Richards: Studies on the intrapulmonary mixture of gases. III. Open circuit method for measuring residual air. J. clin. Invest.19, 609 (1940).
Petit, J. M., G. Milic-Emili etR. Koch: Le volume de réserve expiratoire pendant l'exercise musculaire chez l'homme sain. Arch. int. Physiol.67, 350 (1959).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Vávra, J., Máček, M. Changes of the endexpiratory level and the utilization of lung reserve volumes during exercise. Int. Z. Angew. Physiol. Einschl. Arbeitsphysiol. 26, 124–130 (1968). https://doi.org/10.1007/BF00699509
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00699509