Skip to main content
Log in

Plasma volume estimation in severely ill infants and children using a simplified Evans blue method

  • Published:
European Journal of Pediatrics Aims and scope Submit manuscript

Abstract

Plasma volume was measured using Evans blue dye and 125iodinated human serum albumin (RIHSA) simultaneously in order to evaluate the accuracy of a simplified Evans blue method recommended by Nielsen and Nielsen (1962). 9 studies were performed in 8 newborn infants weighing 1.07 to 2.85 kg and 16 studies in 14 patients aged 6 months to 14 years suffering from severe circulatory disturbances. In 20 studies, plasma volumes measured by Evans blue and by RIHSA agreed within ±5%, and in all the studies within ±10%. The Evans blue method yielded higher plasma volumes than the RIHSA method in 19 instances. The mean difference (paired t-test) was only significant in newborn infants (+4.0±3.6%; P<0.05). The disappearance rates of Evans blue exceeded that of RIHSA in 16 studies, but this was only significant in the patients older than 6 months (+2.3±4.2%/h; P<0.05).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  • Andersen, S. B.: Simultaneous determination of plasma volume with 131I-labelled gammaglobulin, 131I-labelled albumin and T-1824. Clin. Sci. 23, 221–228 (1962)

    Google Scholar 

  • Aust, J. B., Chou, S. N., Marvin, J. F., Brackney, E. L., Moore, G. E.: A rapid method for clinical total blood volume determination using radioactive iodinated human serum albumin (RIHSA). Proc. Soc. Exp. Biol. Med. 77, 514–518 (1951)

    Google Scholar 

  • Brady, L. W., Cooper, D. Y.: Colodzin, M., McClenathan, J. E., King, E. R., Williams, R.: Blood volume studies in normal humans. Surg. Gynec. Obstet. 97, 25–32 (1953)

    Google Scholar 

  • Crispell, K. R., Porter, B., Nieset, R. T.: Studies of plasma volume using human serum albumin tagged with radioactive iodine131. J. clin. Invest. 29, 513–516 (1950)

    Google Scholar 

  • Davies, J. W. L., Topley, E.: A critical evaluation of red cell and plasma volume techniques in patients with civilian injuries. J. clin. Path. 12, 289–302 (1959)

    Google Scholar 

  • Franks, J. J., Zizza, F.: Simultaneous measurement of plasma volume in man with T-1824 and an improved I131-albumin method. J. Appl. Physiol. 13, 299–302 (1958)

    Google Scholar 

  • Freinkel, N., Schreiner, G. E., Athens, J. W., Hiatt, C. W., Breese, S.: Artifactual differences in the distribution of T-1824 and I131-labelled albumin resulting from mixing prior to administration. J. Lab. Clin. Med. 43, 215–226 (1954)

    Google Scholar 

  • Gorten, R. J.: The use of iodine-125 for precordial counting. J. Nucl. Med. 6, 169–174 (1965)

    Google Scholar 

  • Inkley, S. R., Brooks, L., Krieger, H.: A study of methods for the prediction of plasma volume. J. Lab. Clin. Med. 45, 841–850 (1955)

    Google Scholar 

  • Jegier, W., MacLaurin, J., Blankenship, W., Lind, J.: Comparative study of blood volume estimation in the newborn infant using I131 labeled human serum albumin (IHSA) and T-1824. Scand. J. Clin. Lab. Invest. 16, 125–132 (1964)

    Google Scholar 

  • Linderkamp, O., Holthausen, H., Seifert, J., Butenandt, I., Riegel, K. P.: Accuracy of blood volume estimations in critically ill children using 125I-labeled albumin and 51Cr-labeled red cells. Europ. J. Pediat. (in press)

  • Linderkamp, O., Roth, G., Sengespeik, C., Versmold, H., Riegel, K.: Blutvolumen, Serumeisen und Erythrozytenparameter von ausgetragenen, früh abgenabelten Säuglingen im ersten Lebensjahr. Klin. Pädiat. 186, 511–518 (1974)

    Google Scholar 

  • Nielsen, M. H., Nielsen, N. C.: Spectrophotometric determination of Evans blue dye in plasma with individual correction for blank density by a modified Gaeblers method. Scand. J. Clin. Lab. Invest. 14, 605–617 (1962)

    Google Scholar 

  • Parving, H. H., Klebe, J. G., Ingomar, C. J.: Simultaneous determination of plasma volume and transcapillary escape rate with 131I-labelled albumin and T-1824 in the newborn. Acta Paediat. Scand. 62, 248–252 (1973)

    Google Scholar 

  • Schultz, A. L., Hammarstein, J. F., Heller, B. I., Ebert, R. V.: A critical comparison of the T-1824 and iodinated albumin methods for plasma volume measurement. J. clin. Invest. 32, 107–112 (1953)

    Google Scholar 

  • Seifert, J., Messmer, K.: Validity of blood volume determinations in hemorrhagic shock in rats. Europ. surg. Res. 3, 306–316 (1971)

    Google Scholar 

  • Senn, V. Y., Karlson, K. E.: Methodologic and actual error of plasma volume determination. Surgery 44, 1095–1105 (1958)

    Google Scholar 

  • Swan, H., Nelson, A. W.: Blood volume I: Critique: Spun vs. isotope hematocrit; 125RIHSA vs. 51CrRBC. Ann. Surg. 173, 481–495 (1971)

    Google Scholar 

  • Zipf, R. E., Webber, J. M., Grove, G. R.: A comparison of routine plasma volume determination methods using radioiodinated human serum albumin and Evans blue (T-1824). J. Lab. Clin. Med. 45, 800–805 (1955)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Supported by Deutsche Forschungsgemeinschaft, SFB 147

Rights and permissions

Reprints and permissions

About this article

Cite this article

Linderkamp, O., Mader, T., Butenandt, O. et al. Plasma volume estimation in severely ill infants and children using a simplified Evans blue method. Eur J Pediatr 125, 135–141 (1977). https://doi.org/10.1007/BF00489986

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00489986

Key words

Navigation