Summary

The obtainable postoperative intraocular pressure following a TEP in a glaucoma patient with an intraocular pressure of 30 mm Hg is calculated in accordance with the concept that there is no outflow of aqueous humor along Schlemm's canal. If aqueous humor reaches all collector channel openings in the surgical area without resistance, the postoperative intraocular pressure reads 14.75 mm Hg. This intraocular pressure is obtained at a point when a collector channel of 1 mm length and of 32 μm in diameter or two collector channels of 27 μ in diameter or five collector channels of 22 μ in diameter establish connection with the trabecular opening.

Zusammenfassung

Der erreichbare postoperative Augendruck nach einer TEP bei einem Glaukompatienten mit dem Augendruck von 30 mm Hg wird unter der Vorstellung berechnet, daß es keinen Kammerwasserabfluß im Schlemmschen Kanal entlang gibt. Wenn das Kammerwasser alle Collector channel Öffnungen im Operationsgebiet ohne Widerstand erreicht, dann ist der postoperative Augendruck 14,75 mm Hg. Dieser intraokulare Druck wird dann erreicht, wenn ein Collector channel von 1 mm Länge und einem Durchmesser von 32 μ oder zwei Collector channel mit einem Durchmesser von 27 μ oder fünf Collector channel mit einem Durchmesser von 22 μ mit der Trabekelöffnung in Verbindung stehen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Backer, B., Constant, M.A.: The facility of aqueous outflow: a comparison of tonography and perfusion measurements in vivo and in vitro. Arch. Ophthal. 55, 305–312 (1956)

    Google Scholar 

  • Bill, A.: Further studies on the influence of the intraocular pressure on aqueous humor dynamics in cynomolgus monkeys. Invest. Ophthal. 6, 364–372 (1967)

    Google Scholar 

  • Goldmann, H.: Die Kammerwasservenen und das Poiseuille'sche Gesetz. Ophthalmologica (Basel) 118, 496–519 (1949)

    Google Scholar 

  • Goldmann, H.: Bericht über das Symposium: Schwierigkeiten und Irrtümer bei Diagnose und Therapie des Glaukoms. In: Proceedings of the XX International Congress of Ophthalmology, 1966, 519–526. Amsterdam: Excerpta Medica Foundation 1967

    Google Scholar 

  • Grant, W.M.: Further studies on facility of flow through the trabecular meshwork. Arch. Ophthal. 60, 523 (1958)

    Google Scholar 

  • Grant, W.M., Trotter, R.R.: Tonographic measurement in enucleated eyes. Arch. Ophthal. 53, 191–200 (1955)

    Google Scholar 

  • Harms, H., Dannheim, R.: Epicritical consideration of 300 cases of trabeculotomy “ab externe”. Trans ophthal. Soc. U.K. 89, 491–499 (1970)

    Google Scholar 

  • Hoffmann, F., Harnisch, J.-P.: Schlemm's canal after trabeculoelectropuncture (TEP). Albrecht v. Graefes Arch. klin. exp. Ophthal. 203, (1977)

  • Rentsch, L.: Personal communication (1977)

  • McEwen, W.K.: Application of Poiseuille's law to aqueous outflow. Arch. Ophthal. 60, 290–294 (1958)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hoffmann, F. Mathematical consideration of aqueous outflow after Trabeculo-Electropuncture (TEP). Albrecht von Graefes Arch. Klin. Ophthalmol. 204, 87–93 (1977). https://doi.org/10.1007/BF00414709

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00414709

Keywords

Navigation