Required ultracentrifugal time for condensing solution by ultracentrifuge

  • Originals
  • Published:
Bioprocess Engineering Aims and scope Submit manuscript

Abstract

Required ultracentrifugal time for condensing a solution by ultracentrifuge with an angle rotor or a swing rotor was estimated by considering the calculated distribution of concentration in an ultracentrifugal tube. From the calculated distribution of the concentration a free boundary between solvent and solution was found in the ultracentrifugal tube under the condition that t*>0.25. A condense constant was newly defined as the ratio of the mean concentration in the ultracentrifugal tube after removing the solvent to the concentration of initial solution. The equation determining the required ultracentrifugal time for condensing a solution up to a given condense constant is derived and solved numerically. The required ultracentrifugal time for an angle rotor was shorter than that for a swing rotor.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Abbreviations

c kg/m3 :

concentration of solute

c A kg/m3 :

concentration of solute for angle rotor

c S kg/m3 :

concentration of solute for swing rotor

D cm2/s:

diffusion coefficient

d cm:

diameter of ultracentrifugal tube

E :

condense constant

k 1 :

dimensionless constant

k 2 :

dimensionless constant

r cm:

radial coordinate

r 1 cm:

minimum radius of ultracentrifugal tube

r 2 cm:

maximum radius of ultracentrifugal tube

r b cm:

radius of free boundary

s s:

sedimentation constant

t s:

time

t r s:

required ultracentrifugal time

α :

dimensionless parameter

θ :

inclination of ultracentrifugal tube

ω s−1 :

angular velocity of rotation

*:

dimensionless

References

  1. Shiragami, N.; Kajiuchi, T.: Precipitation of protein by ultracentrifuge with angle rotor I. Model for sedimentation process. Bioprocess Eng. 5 (1990) 85–88

    Google Scholar 

  2. Shiragami, N.; Kajiuchi, T.; Matsuda, A.: Precipitation of protein by ultracentrifuge with angle rotor II. Experimental. Bioprocess Eng. 5 (1990) 103–105

    Google Scholar 

Download references

Author information

Authors and Affiliations