Abstract
The power cable is one of the most important transmission equipment. The long cable common use the cross-bonded grounding method to reduce the loss of shielding layer and decrease the voltage rise at the end of cable. Therefore, it is difficult to diagnosis the PD detection result of cross-bonded cable in field because the PD signals will be influenced by both the environment electromagnet interference and the interference among different phases. The broad band sensor is used to detect the PD of cross-bonded cable in field in this paper. The waveform of the PD pulse, PRPD, and 3PARD diagrams are analyzed to diagnose the results. The results have shown that the broadband sensor can anti the environment electromagnet interference because it can obtain more information of PD signal. The 3PARD diagrams can division the interference among different phases.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Petzold, F., Schlapp, H., Gulski, E.: Advanced solution for on-site diagnosis of distribution power cables. IEEE Trans. Dielectr. Electr. Insul. 15(6), 1584–1589 (2008)
He, W., Wang, Q., Huang, C., et al.: A novel noise elimination method for PD measurement of on-site MV cable using frequency-tuned resonant system. In: 2016 International Conference on Condition Monitoring and Diagnosis (CMD), Xi’an, China (2016)
Putter, H.T., Gotz, D., Petzold, F., et al.: Innovative solutions for on-site diagnosis of distribution power cables. In: Transmission & Distribution Conference & Exposition. IEEE (2012)
Koltunowicz, W., Plath, R.: Synchronous multi-channel PD measurements. IEEE Trans. Dielectr. Electr. Insul. 15(6), 1715–1723 (2008)
Kraetge, A., Hoek, S., Hummel, R., et al.: De-noising approaches for partial discharge measurements—a comparison of methods and their practical application. In: International Conference on Condition Monitoring and Diagnosis. IEEE (2013)
Yin, Y., Li, Z.: Research on a practical de-noising method and the characterization of partial discharge UHF signals. IEEE Trans. Dielectr. Elect. Insul. 21(5), 2206–2216 (2014)
Henseler, J., Chin, W.W.: A comparison of approaches for the analysis of interaction effects between latent variables using partial least squares path modeling. Struct. Eqn. Model. Multi. J. 17(1), 82–109 (2010)
Acknowledgements
This work was supported by National Nature Science Foundation of China (NSFC) under Grants No. 61671356, Science and Technology Program of Shaanxi Province under Grants No. 2020GY-136 and 2019ZDLGY14-02-03.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2022 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Wang, L., Liu, B., Wang, B., Han, X., Liu, Z., Sun, W. (2022). PD Detection and Analysis of Cross-Bonded Cable Based on Broadband Sensor and Three-Phase Amplitude Relation Analysis Method. In: Wu, TY., Ni, S., Chu, SC., Chen, CH., Favorskaya, M. (eds) Advances in Smart Vehicular Technology, Transportation, Communication and Applications. Smart Innovation, Systems and Technologies, vol 250. Springer, Singapore. https://doi.org/10.1007/978-981-16-4039-1_33
Download citation
DOI: https://doi.org/10.1007/978-981-16-4039-1_33
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-16-4038-4
Online ISBN: 978-981-16-4039-1
eBook Packages: EngineeringEngineering (R0)