Abstract
Malignant choroidal melanoma is a choroidal tumor arising in the layer of blood vessels located beneath the retina. It is a rare occurrence, affecting five to every million inhabitants and rapidly evolving into metastasis. The stereotactic radiotherapy is one of the possible treatments for the disease, it consists in the application of small photon beams directed to the PTV, the prescribed dose is delivered in multiple sessions. The success of treatment depends directly, among others biomedical factors, on the precision of the application and how the treatment method can hold still the patient’s eye. This study aims: (a) to analyze the eye’s movement during the treatment for choroidal melanoma and the non-invasive method for fixating the patient’s eye; (b) to develop a monitoring software for patient eye gaze; (c) design a mechanical eye to verify the monitoring system. As a result, it is expected that the system will be improved, raising the precision and accuracy of application and reducing the damage to healthy tissues and side effects. After analyzing the positions of the iris center and calculating its displacements relative to the orthophoria point the standard deviation values of 0.368 mm and 0.364 mm were found for the X-axis and Y-axis, respectively. The LED lamp is enough for a noninvasive fixation of the patient’s eye during treatment. The mechanical eye now is able to verify the monitoring system software, as both work with resolutions within the limit given by the eye movement analyzes.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Chauvel P, Sauerwein W, Bornfeld N et al. Clinical and technical requirements for proton treatment planning of ocular diseases. In: Wiegel T, Bornfeld N, Foerster MH, et al. Editors. Radiotherapy of ocular disease. Basel: Karger; 1997, Pp. 133–142.
Dieckmann K, Georg D, Zehetmayer M et al. LINAC based stereotactic radiotherapy of uveal melanoma: Four years clinical experience. Radiother Oncol 2003;67:199–206.
Cruz, D. P. & lopes, J. M. Características clínico-laboratoriais e sobrevida em doentes com melanoma. Arquivos de medicina vol. 23, nº 2, pp. 45–57.
Bicas, H. E. A. Oculomotricidade e seus fundamentos, Arq. Bras. Oftalmol. 2003;66:687–700.
Bernhard Petersch, K. D. Automatic real-time surveillance of eye position and gating for stereotactic radiotherapy of uveal melanoma. Medical Physics, pp. 3521–3527.
Freire, J.E., Brady, L.W., DePotter, P. et al. Malignant melanoma of the posterior uvea. in: C.A. Perez, L.W. Brady et al, (Eds.) Principles and practice of radiation oncology. 3rd ed. Lippincott-Raven, Philadelphia, PA; 1997:871–874.
Dunavoelgyi R., Dieckmann K., Gleiss A., Sacu S., Kircher K., Georgopoulos M. et al. (2011). Local tumor control, visual acuity, and survival after hypofractionated stereotactic photon radiotherapy of choroidal melanoma in 212 patients treated between 1997 and 2007. I. J. Radiation Oncology Biology Physics, pp. 199–205.
Loo W, Tze L. Video Analysis and Modeling Performance Task to Promote Becoming Like Scientists in Classrooms. American Journal of Educational Research. 2015; 3(2):197–207.
D. A. Robinson the mechanics of human saccadic eye movement, j. Phy8iol. (1964), 174, pp. 245–264.
Bose S.,Vahabzadeh S. and Bandyopadhyay A. Bone tissue engineering using 3D printing 2013;16;496–504.
Robinson, D. A., Gordon, J. L. & Gordon, a. S. (16 de Abril de 1986). A Model of the Smooth Pursuit Eye Movement System. Biological Cybernetics Springer-Verlag, p. 15.
Joachim B, Bernhard P, Dietmar G et al. A noninvasive eye fixation and computer-aided eye monitoring system for linear accelerator-based stereotactic radiotherapy of uveal melanoma. Int J Radiation Oncology Biol Phys 2003;56:1128–1136.
Dunavoelgyi R, Dieckmann K, Gleiss A et al. Radiogenic side effects after hypofractionated stereotactic photon radiotherapy of choroidal melanoma in 212 patients treated between 1997 and 2007. Int J Radiation Oncology Biol Phys 2012;83:121–128.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Ethics declarations
The authors declare that they have no conflict of interest.
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Souza, F., Valani, J., Gonçalves, O.D., Batista, D.V.S., Cardoso, S.C., Pereira, D.D. (2019). Stereotactic Radiotherapy for Choroidal Melanoma: Analysis of Eye Movement During Treatment, Eye Simulator Design and Automated Monitoring System Development. In: Lhotska, L., Sukupova, L., Lacković, I., Ibbott, G. (eds) World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings, vol 68/3. Springer, Singapore. https://doi.org/10.1007/978-981-10-9023-3_89
Download citation
DOI: https://doi.org/10.1007/978-981-10-9023-3_89
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-9022-6
Online ISBN: 978-981-10-9023-3
eBook Packages: EngineeringEngineering (R0)