Evaluation of Downtime of Linear Accelerators Installed at Radiotherapy Departments in the Czech Republic

  • Conference paper
  • First Online:
World Congress on Medical Physics and Biomedical Engineering 2018

Part of the book series: IFMBE Proceedings ((IFMBE,volume 68/3))

Abstract

The National Radiation Protection Institute (NRPI) performed the study evaluating linear accelerator (linac) unscheduled downtime and other parameters related to linac failure (e.g. treatment cancellations, patients transferred to other linac, patients treated with modified dose fractionation) at radiotherapy departments in the Czech Republic. Thirteen radiotherapy departments with at least one linac (out of 21 departments in the Czech Republic) voluntarily participated in the study covering 29 out of 47 linacs. Downtime was evaluated for a one year period from July of 2016 to June of 2017. The methodology was as follows: NRPI designed the data entry form which was sent electronically to medical physicists at participating radiotherapy departments. Data related to linac failures were filled in. The completed forms were evaluated by NRPI. Unscheduled downtime was defined as time when linac cannot be operated during operating hours. Unscheduled downtime per linac per year ranged from 4 to 222 h (mean = 73 h, median = 61 h). Downtime percentage calculated as a ratio of downtime and total sum of operating hours per year ranged from 0.2 to 7.6% (mean = 2.8%, median = 2.2%). The number of treatment cancellations per linac per year ranged from 0 to 661. Unified methodology enabled objective comparison of linac downtime at particular radiotherapy departments in the Czech Republic. The study confirmed usefulness of having minimally two matched linacs at a department. The results of this study could help radiotherapy departments negotiate better service contract (e.g. agreement on maximum guaranteed downtime).

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

Acknowledgements

This work was done under a contract by the State Office for Nuclear Safety of the Czech Republic. The authors would like to thank the medical physicists and other personnel from radiotherapy departments who took part in this study for their cooperation.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Vladimir Dufek .

Editor information

Editors and Affiliations

Ethics declarations

The authors declare that they have no conflict of interest.

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Dufek, V., Horakova, I. (2019). Evaluation of Downtime of Linear Accelerators Installed at Radiotherapy Departments in the Czech Republic. In: Lhotska, L., Sukupova, L., Lacković, I., Ibbott, G. (eds) World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings, vol 68/3. Springer, Singapore. https://doi.org/10.1007/978-981-10-9023-3_63

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-9023-3_63

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-9022-6

  • Online ISBN: 978-981-10-9023-3

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics