Summary
The declinations of stars are determined by the circle micrometers on the meridian circle. The determined accuracy of declinations depends on the systematic accuracy of the micrometers. The DCMT (Danish Chinese Meridian Telescope) adopts photoelectric scanning micrometers as the circle reading system. It contains 6 micrometers forming 3 pairs to measure the circle posistion simultaneously. The repeatability of the circle reading and systematic errors of micrometers are discussed in this paper.
To measure the repeatability, we fix the circle and the 6 micrometers scan the division lines simultaneously. The mean square error of the position for a. line derived from the repeated scans of a. micrometer is the repeatability of the reading. The position of a. line is calculated from the readout values in a. profile by means of the linear least-squares fit. It is measured that the repeatability for all six micrometers is better than 0.’03 and the average value is 0.’022.
The systematic error of a. micrometer means that the scanning distance is not proportional to the angle distance on the circle which is scanned. It is caused by many parameters of the micrometer. We have found that the systematic error strongly depends on the adjustment status of the micormeter.
The systematic error can be described with a. density function of the distribution of errors g(x), where x∈[0.T], T is the maximum of scanning. If the positions r1, r2 (r1 > r2) of two adjacent lines are measured, we can get the corrections to the systematic errors. The accuracy of the position measurement is greatly improved after the correction. The mean error of the distance measurements between two lines for single micrometer reaches 0.’061 and the accuracy for every micrometer is similar, while this error is more high and different for distinct micrometers without correction. The single measurement of single line has a. accuracy of 0.’043 with correction.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Einicke, O.H. et al. 1971, Astro. & Astrophys., 10
Li Huanxin, 1990. Publ. of CSAO, Vol.13, No.1.
Li Huanxin, 1991, Publ. of CSAO, Vol.14, No.2.
Diu Linsheng, Li Zhigang, 1991, Publ. of CSAO, Vol.14, No.l.
Zhu Zi, Liu Shaomin, 1991, Publ. of CSAO, Vol.14, No.1.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1993 Springer Science+Business Media Dordrecht
About this paper
Cite this paper
Zi, Z. (1993). Researches on The Accuracy of the DCMT Circle Reading System. In: Mueller, I.I., Kołaczek, B. (eds) Developments in Astrometry and Their Impact on Astrophysics and Geodynamics. International Astronomical Union / Union Astronomique Internationale, vol 156. Springer, Dordrecht. https://doi.org/10.1007/978-94-011-1711-1_24
Download citation
DOI: https://doi.org/10.1007/978-94-011-1711-1_24
Publisher Name: Springer, Dordrecht
Print ISBN: 978-0-7923-2238-2
Online ISBN: 978-94-011-1711-1
eBook Packages: Springer Book Archive