Abstract
The oratory of St. Giuseppe dei Minimi in L’Aquila, Italy, sustained serious damage after the seismic events of April 2009. The earthquake caused out-of-plane overturning of the façade, with wide cracks on both lateral walls. Such rotation caused the “sinking” in the crack of one of the pillars of the belfry, which did not collapse, but remained in a very dangerous situation.
After the initial stabilisation measures, carried out during the months following the seismic event, field investigations were carried out by the authors in spring-summer 2010, to guide the final strengthening intervention, supervised by the Italian Ministry of Culture.
The investigation campaign involved intensive use of non and minor destructive techniques, such as thermography, radar, sonic tests, core sampling, single and double flat jack tests and chemical analysis on sampled materials. Moreover, the overall dynamic characteristics of the church were extracted from vibrations measured in the upper areas of the building, using output only techniques.
Finally, a structural monitoring system was installed in the church (involving also the adjacent St. Biagio church), to monitor the damage progression and to evaluate the effectiveness of strengthening applications.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
RILEM Recommendation TC 127-MS (1996). MS.D.1 Measurement of mechanical pulse velocity for masonry, (published in Materials and Structures, Vol. 29, October 1996 pp. 463–466).
Maldague, X. (2001). ‘Infrared technology for non-destructive testing’, John Wiley and Sons, Inc. (Ed.), ISBN 0-471-18190-0.
ASTM D6432-99 (2005). Standard guide for using the surface ground penetrating radar method for subsurface investigation
RILEM Recommendation MDT.D.4 (2004). In-situ stress tests based on the flat-jack, (published in Materials and Structures, Vol. 37, N. 7, 491–496, DOI: 10.1007/BF02481588).
RILEM Recommendation MDT.D.5 (2004). In-situ stress-strain behaviour tests based on the flat-jack, (published in Materials and Structures, Vol. 37, N. 7, 497–5001, DOI: 10.1007/BF02481589).
Brincker, R., Zhang, L., and Andersen P. (2000). Modal Identification from Ambient Responses using Frequency Domain Decomposition. Proceedings 18th International Modal Analysis Conference, San Antonio, TX
Casarin F., Valluzzi M.R., da Porto F., Modena C. (2008). Structural monitoring for the evaluation of the dynamic response of historical monuments, SACoMaTiS 2008, eds. L. Binda, M. di Prisco, R. Felicetti, ISBN 978-2-35158-061-5, p. 787–796, Publisher RILEM Publications SARL
Guidelines for evaluation and mitigation of seismic risk to cultural heritage with reference to technical constructions regulation (2006). Ministry for Cultural Heritage and Activities, General Direction of Architectural Heritage and Landscape – Dept. of Civil Protection Agency (Italy)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 RILEM
About this paper
Cite this paper
Casarin, F. et al. (2013). Structural Monitoring and Investigation Campaign in the Church of St. Giuseppe dei Minimi in L’Aquila, After the 6th of April 2009 Earthquake. In: Güneş, O., Akkaya, Y. (eds) Nondestructive Testing of Materials and Structures. RILEM Bookseries, vol 6. Springer, Dordrecht. https://doi.org/10.1007/978-94-007-0723-8_165
Download citation
DOI: https://doi.org/10.1007/978-94-007-0723-8_165
Published:
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-007-0722-1
Online ISBN: 978-94-007-0723-8
eBook Packages: EngineeringEngineering (R0)