Skip to main content

Postoperative Graft Management in Endothelial Keratoplasty

  • Chapter
  • First Online:
Mastering Endothelial Keratoplasty

Abstract

Despite the surgical challenges during the endothelial keratoplasty (EK) procedures, postoperative management is of utmost importance for graft survival. One of the most important aspects of postoperative care is the management of topical steroid dosage, since sudden discontinuation of treatment has been identified as the main cause of graft failure in several reports. There are also potential challenges that can present to the surgeon both in the early and late postoperative period, such as fluid in the interface and graft detachment; or immunologic rejection or graft failure, respectively. In the initial portion of this chapter, routine management of an uncomplicated graft is described, followed by the description and management of several scenarios that could present along the postoperative period.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 119.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Wu EI, Ritterband DC, Yu G, et al. Graft rejection following descemet stripping automated endothelial keratoplasty: features, risk factors, and outcomes. Am J Ophthalmol. 2012;153(5):949–57 e1.

    Article  Google Scholar 

  2. Shimazaki J, Iseda A, Satake Y, Shimazaki-Den S. Efficacy and safety of long-term corticosteroid eye drops after penetrating keratoplasty: a prospective, randomized, clinical trial. Ophthalmology. 2012;119(4):668–73.

    Article  PubMed  Google Scholar 

  3. Price MO, Price Jr FW, Kruse FE, et al. Randomized comparison of topical prednisolone acetate 1% versus fluorometholone 0.1% in the first year after descemet membrane endothelial keratoplasty. Cornea. 2014;33(9):880–6.

    Article  PubMed  Google Scholar 

  4. Li JY, Terry MA, Goshe J, et al. Three-year visual acuity outcomes after descemet’s stripping automated endothelial keratoplasty. Ophthalmology. 2012;119(6):1126–9.

    Article  PubMed  Google Scholar 

  5. van Dijk K, Ham L, Tse WH, et al. Near complete visual recovery and refractive stability in modern corneal transplantation: descemet membrane endothelial keratoplasty (DMEK). Cont Lens Anterior Eye. 2013;36(1):13–21.

    Article  PubMed  Google Scholar 

  6. Guerra FP, Anshu A, Price MO, et al. Descemet’s membrane endothelial keratoplasty: prospective study of 1-year visual outcomes, graft survival, and endothelial cell loss. Ophthalmology. 2011;118(12):2368–73.

    Article  PubMed  Google Scholar 

  7. Terry MA, Shamie N, Chen ES, et al. Endothelial keratoplasty a simplified technique to minimize graft dislocation, iatrogenic graft failure, and pupillary block. Ophthalmology. 2008;115(7):1179–86.

    Article  PubMed  Google Scholar 

  8. Hayes DD, Shih CY, Shamie N, et al. Spontaneous reattachment of descemet stripping automated endothelial keratoplasty lenticles: a case series of 12 patients. Am J Ophthalmol. 2010;150(6):790–7.

    Article  PubMed  Google Scholar 

  9. Srinivasan S, Rootman DS. Slit-lamp technique of draining interface fluid following descemet’s stripping endothelial keratoplasty. Br J Ophthalmol. 2007;91(9):1202–5.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Suh LH, Yoo SH, Deobhakta A, et al. Complications of descemet’s stripping with automated endothelial keratoplasty: survey of 118 eyes at One Institute. Ophthalmology. 2008;115(9):1517–24.

    Article  PubMed  Google Scholar 

  11. Juthani VV, Goshe JM, Srivastava SK, Ehlers JP. Association between transient interface fluid on intraoperative OCT and textural interface opacity after DSAEK surgery in the PIONEER study. Cornea. 2014;33(9):887–92.

    Article  PubMed  PubMed Central  Google Scholar 

  12. Steven P, Le Blanc C, Velten K, et al. Optimizing descemet membrane endothelial keratoplasty using intraoperative optical coherence tomography. JAMA Ophthalmol. 2013;131(9):1135–42.

    Article  PubMed  Google Scholar 

  13. Price Jr FW, Price MO. Descemet’s stripping with endothelial keratoplasty in 200 eyes: early challenges and techniques to enhance donor adherence. J Cataract Refract Surg. 2006;32(3):411–8.

    Article  PubMed  Google Scholar 

  14. Droutsas K, Ham L, Dapena I, et al. Visual acuity following descemet-membrane endothelial keratoplasty (DMEK): first 100 cases operated on for Fuchs endothelial dystrophy. Klin Monbl Augenheilkd. 2010;227(6):467–77.

    Article  CAS  PubMed  Google Scholar 

  15. Terry MA, Hoar KL, Wall J, Ousley P. Histology of dislocations in endothelial keratoplasty (DSEK and DLEK): a laboratory-based, surgical solution to dislocation in 100 consecutive DSEK cases. Cornea. 2006;25(8):926–32.

    Article  PubMed  Google Scholar 

  16. Koenig SB, Covert DJ. Early results of small-incision descemet’s stripping and automated endothelial keratoplasty. Ophthalmology. 2007;114(2):221–6.

    Article  PubMed  Google Scholar 

  17. Gorovoy MS. Descemet-stripping automated endothelial keratoplasty. Cornea. 2006;25(8):886–9.

    Article  PubMed  Google Scholar 

  18. Hood CT, Woodward MA, Bullard ML, Shtein RM. Influence of preoperative donor tissue characteristics on graft dislocation rate after descemet stripping automated endothelial keratoplasty. Cornea. 2013;32(12):1527–30.

    Article  PubMed  Google Scholar 

  19. Terry MA, Shamie N, Chen ES, et al. Endothelial keratoplasty: the influence of preoperative donor endothelial cell densities on dislocation, primary graft failure, and 1-year cell counts. Cornea. 2008;27(10):1131–7.

    Article  PubMed  Google Scholar 

  20. Monnereau C, Quilendrino R, Dapena I, et al. Multicenter study of descemet membrane endothelial keratoplasty: first case series of 18 surgeons. JAMA Ophthalmol. 2014;132(10):1192–8.

    Article  PubMed  Google Scholar 

  21. Yeh RY, Quilendrino R, Musa FU, et al. Predictive value of optical coherence tomography in graft attachment after descemet’s membrane endothelial keratoplasty. Ophthalmology. 2013;120(2):240–5.

    Article  PubMed  Google Scholar 

  22. Kam KW, Young AL. Spontaneous reattachment of a posteriorly dislocated endothelial graft: a case report. Case Rep Transplant. 2013;2013:631702.

    PubMed  PubMed Central  Google Scholar 

  23. Acar BT, Muftuoglu O, Acar S. Comparison of sulfur hexafluoride and air for donor attachment in descemet stripping endothelial keratoplasty in patients with pseudophakic bullous keratopathy. Cornea. 2014;33(3):219–22.

    Article  PubMed  Google Scholar 

  24. Guell JL, Morral M, Gris O, et al. Bimanual technique for insertion and positioning of endothelium-descemet membrane graft in descemet membrane endothelial keratoplasty. Cornea. 2013;32(12):1521–6.

    Article  PubMed  Google Scholar 

  25. Landry H, Aminian A, Hoffart L, et al. Corneal endothelial toxicity of air and SF6. Invest Ophthalmol Vis Sci. 2011;52(5):2279–86.

    Article  CAS  PubMed  Google Scholar 

  26. Mojica G, Padnick-Silver L, Macsai MS. Incidence of presumed iatrogenic graft failure in descemet stripping automated endothelial keratoplasty. Cornea. 2012;31(8):872–5.

    Article  PubMed  Google Scholar 

  27. Letko E, Price DA, Lindoso EM, et al. Secondary graft failure and repeat endothelial keratoplasty after descemet’s stripping automated endothelial keratoplasty. Ophthalmology. 2011;118(2):310–4.

    Article  PubMed  Google Scholar 

  28. Price MO, Gorovoy M, Benetz BA, et al. Descemet’s stripping automated endothelial keratoplasty outcomes compared with penetrating keratoplasty from the Cornea Donor Study. Ophthalmology. 2010;117(3):438–44.

    Article  PubMed  PubMed Central  Google Scholar 

  29. Price MO, Fairchild KM, Price DA, Price Jr FW. Descemet’s stripping endothelial keratoplasty five-year graft survival and endothelial cell loss. Ophthalmology. 2011;118(4):725–9.

    Article  PubMed  Google Scholar 

  30. Li JY, Terry MA, Goshe J, et al. Graft rejection after descemet’s stripping automated endothelial keratoplasty: graft survival and endothelial cell loss. Ophthalmology. 2012;119(1):90–4.

    Article  PubMed  Google Scholar 

  31. Terry MA, Chen ES, Shamie N, et al. Endothelial cell loss after descemet’s stripping endothelial keratoplasty in a large prospective series. Ophthalmology. 2008;115(3):488–96 e3.

    Article  PubMed  Google Scholar 

  32. Price MO, Price Jr FW. Endothelial cell loss after descemet stripping with endothelial keratoplasty influencing factors and 2-year trend. Ophthalmology. 2008;115(5):857–65.

    Article  PubMed  Google Scholar 

  33. Price MO, Gorovoy M, Price Jr FW, et al. Descemet’s stripping automated endothelial keratoplasty: three-year graft and endothelial cell survival compared with penetrating keratoplasty. Ophthalmology. 2013;120(2):246–51.

    Article  PubMed  Google Scholar 

  34. Lee WB, Jacobs DS, Musch DC, et al. Descemet’s stripping endothelial keratoplasty: safety and outcomes: a report by the American Academy of Ophthalmology. Ophthalmology. 2009;116(9):1818–30.

    Article  PubMed  Google Scholar 

  35. Feng MT, Price MO, Miller JM, Price Jr FW. Air reinjection and endothelial cell density in descemet membrane endothelial keratoplasty: five-year follow-up. J Cataract Refract Surg. 2014;40(7):1116–21.

    Article  PubMed  Google Scholar 

  36. Phillips PM, Terry MA, Kaufman SC, Chen ES. Epithelial downgrowth after descemet-stripping automated endothelial keratoplasty. J Cataract Refract Surg. 2009;35(1):193–6.

    Article  PubMed  Google Scholar 

  37. Zhang Q, Randleman JB, Stulting RD, et al. Clinicopathologic findings in failed descemet stripping automated endothelial keratoplasty. Arch Ophthalmol. 2010;128(8):973–80.

    Article  PubMed Central  Google Scholar 

  38. Yoeruek E, Hofmann J, Bartz-Schmidt KU. Histological and ultrastructural findings of corneal tissue after failed descemet membrane endothelial keratoplasty. Acta Ophthalmol. 2014;92(3):e213–6.

    Article  PubMed  Google Scholar 

  39. Tenkman LR, Price FW, Price MO. Descemet membrane endothelial keratoplasty donor preparation: navigating challenges and improving efficiency. Cornea. 2014;33(3):319–25.

    Article  PubMed  Google Scholar 

  40. Terry MA, Saad HA, Shamie N, et al. Endothelial keratoplasty: the influence of insertion techniques and incision size on donor endothelial survival. Cornea. 2009;28(1):24–31.

    Article  PubMed  Google Scholar 

  41. Kaiserman I, Bahar I, McAllum P, et al. Suture-assisted vs forceps-assisted insertion of the donor lenticula during descemet stripping automated endothelial keratoplasty. Am J Ophthalmol. 2008;145(6):986–90.

    Article  PubMed  Google Scholar 

  42. Bahar I, Kaiserman I, Sansanayudh W, et al. Busin guide vs forceps for the insertion of the donor lenticule in descemet stripping automated endothelial keratoplasty. Am J Ophthalmol. 2009;147(2):220–6 e1.

    Article  PubMed  Google Scholar 

  43. Khor WB, Han SB, Mehta JS, Tan DT. Descemet stripping automated endothelial keratoplasty with a donor insertion device: clinical results and complications in 100 eyes. Am J Ophthalmol. 2013;156(4):773–9.

    Article  CAS  PubMed  Google Scholar 

  44. Pedersen IB, Ivarsen A, Hjortdal J. Graft rejection and failure following endothelial keratoplasty (DSAEK) and penetrating keratoplasty for secondary endothelial failure. Acta Ophthalmol. 2015;93(2):172–7.

    Google Scholar 

  45. Ezon I, Shih CY, Rosen LM, et al. Immunologic graft rejection in descemet’s stripping endothelial keratoplasty and penetrating keratoplasty for endothelial disease. Ophthalmology. 2013;120(7):1360–5.

    Article  PubMed  Google Scholar 

  46. Jordan CS, Price MO, Trespalacios R, Price Jr FW. Graft rejection episodes after descemet stripping with endothelial keratoplasty: part one: clinical signs and symptoms. Br J Ophthalmol. 2009;93(3):387–90.

    Article  CAS  PubMed  Google Scholar 

  47. Anshu A, Price MO, Price Jr FW. Risk of corneal transplant rejection significantly reduced with descemet’s membrane endothelial keratoplasty. Ophthalmology. 2012;119(3):536–40.

    Article  PubMed  Google Scholar 

  48. Busin M, Albe E. Does thickness matter: ultrathin descemet stripping automated endothelial keratoplasty. Curr Opin Ophthalmol. 2014;25(4):312–8.

    Article  PubMed  Google Scholar 

  49. Busin M, Madi S, Santorum P, et al. Ultrathin descemet’s stripping automated endothelial keratoplasty with the microkeratome double-pass technique: two-year outcomes. Ophthalmology. 2013;120(6):1186–94.

    Article  PubMed  Google Scholar 

  50. Price MO, Jordan CS, Moore G, Price Jr FW. Graft rejection episodes after descemet stripping with endothelial keratoplasty: part two: the statistical analysis of probability and risk factors. Br J Ophthalmol. 2009;93(3):391–5.

    Article  CAS  PubMed  Google Scholar 

  51. Baydoun L, van Dijk K, Dapena I, et al. Repeat descemet membrane endothelial keratoplasty after complicated primary descemet membrane endothelial keratoplasty. Ophthalmology. 2015;122(1):8–16.

    Google Scholar 

  52. Itty S, Proia AD, DelMonte DW, et al. Clinical course and origin of epithelium in cases of epithelial downgrowth after descemet stripping automated endothelial keratoplasty. Cornea. 2014;33(11):1140–4.

    Article  PubMed  Google Scholar 

  53. Bansal R, Ramasubramanian A, Das P, et al. Intracorneal epithelial ingrowth after descemet stripping endothelial keratoplasty and stromal puncture. Cornea. 2009;28(3):334–7.

    Article  PubMed  Google Scholar 

  54. Wong RK, Greene DP, Shield DR, et al. 5-Fluorouracil for epithelial downgrowth after descemet stripping automated endothelial keratoplasty. Cornea. 2013;32(12):1610–2.

    Article  PubMed  Google Scholar 

  55. Anshu A, Planchard B, Price MO, et al. A cause of reticular interface haze and its management after descemet stripping endothelial keratoplasty. Cornea. 2012;31(12):1365–8.

    Article  PubMed  Google Scholar 

  56. Price MO, Price Jr FW. Descemet’s stripping with endothelial keratoplasty: comparative outcomes with microkeratome-dissected and manually dissected donor tissue. Ophthalmology. 2006;113(11):1936–42.

    Article  PubMed  Google Scholar 

  57. Ahmed KA, McLaren JW, Baratz KH, et al. Host and graft thickness after descemet stripping endothelial keratoplasty for Fuchs endothelial dystrophy. Am J Ophthalmol. 2010;150(4):490–7 e2.

    Article  PubMed  Google Scholar 

  58. Seery LS, Nau CB, McLaren JW, et al. Graft thickness, graft folds, and aberrations after descemet stripping endothelial keratoplasty for Fuchs dystrophy. Am J Ophthalmol. 2011;152(6):910–6.

    Article  PubMed  PubMed Central  Google Scholar 

  59. Shinton AJ, Tsatsos M, Konstantopoulos A, et al. Impact of graft thickness on visual acuity after descemet’s stripping endothelial keratoplasty. Br J Ophthalmol. 2012;96(2):246–9.

    Article  PubMed  Google Scholar 

  60. Terry MA, Straiko MD, Goshe JM, et al. Descemet’s stripping automated endothelial keratoplasty: the tenuous relationship between donor thickness and postoperative vision. Ophthalmology. 2012;119(10):1988–96.

    Article  PubMed  Google Scholar 

  61. America EBAo. Eye banking statistical report. Washington: Eye Bank Association of America; 2010. p. 1–5.

    Google Scholar 

  62. Rose L, Briceno CA, Stark WJ, et al. Assessment of eye bank-prepared posterior lamellar corneal tissue for endothelial keratoplasty. Ophthalmology. 2008;115(2):279–86.

    Article  PubMed  Google Scholar 

  63. Price MO, Baig KM, Brubaker JW, Price Jr FW. Randomized, prospective comparison of precut vs surgeon-dissected grafts for descemet stripping automated endothelial keratoplasty. Am J Ophthalmol. 2008;146(1):36–41.

    Article  PubMed  Google Scholar 

  64. Chen ES, Terry MA, Shamie N, et al. Precut tissue in descemet’s stripping automated endothelial keratoplasty donor characteristics and early postoperative complications. Ophthalmology. 2008;115(3):497–502.

    Article  PubMed  Google Scholar 

  65. Terry MA. Endothelial keratoplasty: a comparison of complication rates and endothelial survival between precut tissue and surgeon-cut tissue by a single DSAEK surgeon. Trans Am Ophthalmol Soc. 2009;107:184–91.

    PubMed  PubMed Central  Google Scholar 

  66. Mehta JS, Shilbayeh R, Por YM, et al. Femtosecond laser creation of donor cornea buttons for descemet-stripping endothelial keratoplasty. J Cataract Refract Surg. 2008;34(11):1970–5.

    Article  PubMed  Google Scholar 

  67. Cheng YY, Kang SJ, Grossniklaus HE, et al. Histologic evaluation of human posterior lamellar discs for femtosecond laser descemet’s stripping endothelial keratoplasty. Cornea. 2009;28(1):73–9.

    Article  PubMed  Google Scholar 

  68. Vira S, Shih CY, Ragusa N, et al. Textural interface opacity after descemet stripping automated endothelial keratoplasty: a report of 30 cases and possible etiology. Cornea. 2013;32(5):e54–9.

    Article  PubMed  Google Scholar 

  69. Chhadva P, Cabot F, Ziebarth N, et al. Persistent corneal opacity after descemet stripping automated endothelial keratoplasty suggesting inert material deposits into the interface. Cornea. 2013;32(11):1512–3.

    Article  PubMed  Google Scholar 

  70. Rudolph M, Laaser K, Bachmann BO, et al. Corneal higher-order aberrations after descemet’s membrane endothelial keratoplasty. Ophthalmology. 2012;119(3):528–35.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Claudia Perez-Straziota MD .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer India

About this chapter

Cite this chapter

Perez-Straziota, C., Rocha, K.M., Au, J. (2016). Postoperative Graft Management in Endothelial Keratoplasty. In: Jacob, S. (eds) Mastering Endothelial Keratoplasty . Springer, New Delhi. https://doi.org/10.1007/978-81-322-2821-9_5

Download citation

  • DOI: https://doi.org/10.1007/978-81-322-2821-9_5

  • Published:

  • Publisher Name: Springer, New Delhi

  • Print ISBN: 978-81-322-2819-6

  • Online ISBN: 978-81-322-2821-9

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics