Abstract
Our total hip system is based not only upon the use of aluminium oxide ceramic, but also upon a return to the principle of cementless fixation. The importance of this principle was demonstrated by our histopathologic studies of the first Judet prosthesis made of polymethylmethacrylate (PMMA) (Mittelmeier and Singer, 1956). We discovered the importance of fatigue fractures and surface wear of this prosthesis, resulting in marked foreign-body reactions to the wear debris, as well as the significance of biomechanical effects, which not only stimulate the formation of a new load-bearing bone layer, but also create excessive stresses on the new bone with consequent loosening as a result of resorption. Thus, some 25 years ago we suggested increasing the surface area of the implant as a means of solving the problem of endoprosthetic fixation, reasoning that this would promote adaptation of the bone, improve the distribution of stresses, and reduce compressive forces below the critical resorption threshold, thereby effecting a balance between load and structure and preventing prosthetic loosening.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Bentler H, Lehmann M, Strähli G (1974) Verschleißverhalten medizinaltechnischer Werkstoffe, Sulzer Technische Rundschau
Biehl G, Harms J, Mäusle E (1975) Tierexperimentelle und histopathologische Untersuchungen über die Anpassungsvorgänge des Knochens nach der Implantation von “Tragrippen-Endoprothesen”. Arch Orthop Unfallchir 81:105
Boutin P (1972) Arthroplastie totale de la hanche par prothèse en alumine frittée. Rev Chir Orthop 58:229
Charnley J (1974) Clinical and laboratory observations on the rate of wear of different plastic materials in the sockets of artificial hip joints. 55th Scientific Meeting: “Materials for use in medicine and bilogy”, Cambridge
Charnley J (1979) Low friction arthroplasty of the hip. Theory and practice. Springer, Berlin Heidelberg New York
Diehl K, Harms J (1976) Beanspruchung und Umbau bei der Alloarthroplastik des coxalen Femurendes des Hundes mit einer selbsthaftenden Tragrippenprothese. Arch orthop Unfall-Chir 84:89–104
Diehl K, Harms J (1976 b) Über die Aussagekraft tierexperimenteller Ergebnisse mit Hüftendoprothesen. Z Orthop 114:17–25
Dörre E, Beutler H, Geduldig D (1975) Anforderungen an oxidkeramische Werkstoffe als Biomaterial fur künstliche Gelenke. Arch Orthop Unfallchir 83:269
Dörre E, Geduldig D, Happel M, Lade R, Prüssner P. Willert HG, Zichner L (1976) Animal studies on bone ingrowth kinetics of ceramic material under dynamic stress. J Biomed Mater Res 10:493–502
Griss P, Krempien B, Andria.n-Werburg H v, Heimke G, Fleiner R (1973) Experimentelle Untersuchung zur Gewebeverträglichkeit oxidkeramischer (A1203) Abriebteilen. Arch Orthop Unfallchir 76:270
Groher W (1980) Erfahrungen mit der KeramikTragrippen-Hüftprothese nach Mittelmeier. Med Orthop Techn 100:30
Harms J, Mäusle E (1980) Biokompatibilität von Implantaten in der Orthopädie. Hefte Unfallheilkd 144:1–118
Harms J, Mittelmeier M (1980) Statistische Auswertung von 4 Jahren klinischer Prüfung der Hüft-Alloplastik mit Keramik-Tragrippen-Endoprothesen. Med Orthop Techn 100:25–29
Judet R (1975) Totale Hüftendoprothesen aus Porometall ohne Zementverankerung. Z Orthop 113:828–829
Mittelmeier H (1974) Zementlose Verankerung von Endoprothesen nach dem Tragrippenprinzip. Z Orthop 112:27
Mittelmeier H (1975) Selbsthaftende KeramikMetall-Verbund-Endoprothesen (“TragrippenProthese”). Med Orthop Techn 95:152–159
Mittelmeier H (1976) Anchoring hip endoprosthesis without bone cement. In: Schaldach M, Hohmann D (eds) Engineering in medicine, vol 2. Advances in artificial hip and knee joint technology. Springer, Berlin Heidelberg New York, p 387
Mittelmeier H (1979) Keramik-Tragrippen-Prothesen ohne Zement (Kongreßbericht 1979). Langenbecks Arch Chir 349:315–319
Mittelmeier H (1980) Biomechanisch bedingte Grenzschichtreaktionen des Knochengewebes bei Verankerung von Endoprothesen. In: Jäger M, Hackenbroch MH, Refior HJ (Hrsg) Grenzschichtprobleme der Verankerung von Implantation unter besonderer Berücksichtigung von Endoprothesen. Thieme, Stuttgart
Mittelmeier H (1980) Sonderindikationen fur zementfrei implantierbare Keramik-TragrippenEndoprothesen. Med Orthop Techn 100:32–35
Mittelmeier H (1980) Problemfälle bei der Hüftalloplastik mit Keramik-Tragrippenprothesen. Med Orthop Techn 100:36–38
Mittelmeier H (1980) 4 Jahre klinische Erfahrung mit Keramik-Tragrippen-Hüftprothesen. Med Orthop Techn 100:19
Mittelmeier H (1981) Implantate aus AluminiumOxyd-Keramik. Symp. über Biomaterialien. Schriftenreihe der Med Orthop Techn 5:76 (Gentner Verlag)
Mittelmeier H (im Druck) Alloarthroplastik des Hüftglenkes derzeitiger Stand (Unter besonderer Berücksichtigung von Keramik-Endoprothesen). Therapie-Woche
Mittelmeier H, Harms J (1977) Die Anwendung von Keramik in der Gelenkersatz-Chirurgie. Med Orthop Techn 97:55–57
Mittelmeier H, Harms J (1979) Hüftalloplastik mit Keramik-Endoprothesen bei traumatischen Hüftschäden (Unter besonderer Berücksichtigung zementfrei implantierbarer “Autophor”-Tragrippen-Endoprothesen. Unfallheilkunde 82:67–75
Mittelmeier H, Harms J (1979) Derzeitiger Stand der zementfreien Verankerung von Keramik-Metall-Verbundprothesen. Z Orthop 117:478–481
Mittelmeier H, Harms J (1980) Pathologische Verankerungen an Implantatlager bei Endoprothetik mit Zementimplantation und Selbstverankerung. 16. Jahrestagung d. Dtsch. Ges. f. Plast. und Wiederherstellungschir., Düsseldorf 1978. Springer, Berlin Heidelberg New York, S 298
Mittelmeier H, Singer L (1956) Anatomische und histologische Untersuchungen von Arthroplastikgelenken mit Plexiglas-Endoprothesen. Arch Orthop Unfallchir 48:519
Mittelmeier H, Dawihl W, Dörre E, Altmeyer G, Hanser U (1979) Zur Tribologie von Hüftgelenksendoprothesen aus Aluminiumoxydkeramik. Med Orthop Techn 99:114
Mittelmeier H, Harms J, Mäusle E (1979) The biocompatibility of alumina ceramics. 10. Congr. of the European Federation of the Int. College of Surgeons, Milan 1977.
Mittelmeier H, Biehl G, Harms J (1980) Röntgenologische Anpassungsvorgänge des Prothesenlagers bei zementfreier Verankerung von Keramik-Tragrippen-Endoprothesen. In: Jäger M, Hackenbroch MH, Refior HJ (Hrsg) Grenzschichtprobleme der Verankerung von Implantaten unter besonderer Berücksichtigung von Endoprothesen. Thieme, Stuttgart
Mittelmeier H, Hanser U, Harms J (1980) Lösung des biochemischen und mechanischen Zementproblems mit Apatit-Carbonfaser-Zement? In: Jä ger M, Hackenbroch MH, Refior HJ (Hrsg) Osteosynthese, Endoprothetik und Biomechanik der Gelenke. Thieme, Stuttgart, S 62–68
Mittelmeier H, Hanser U, Harms J (1980) Zur Lösung des Zementproblems mittels Apatit-Carbonfaser-Knochenzement. Z Orthop 118:658
Müller ME (1970) Total hip prosthesis. Clin Orthop 72:46
Müller ME (1974) Der derzeitige Stand der Totalendoprothese des Hüftgelenkes. Z Orthop 112:933
Rossak K, Brinkmann KE (1980) Erfahrungen mit dem Einsatz von Keramik-Totalprothesen zum Austausch ausgelockerter Totalendoprothesen des Hüftgelenkes. Med Orthop Techn 100:31–32
Salzer M, Zweymüller K, Locke H, Plenk H Jr, Punzet G (1975) Erste Erfahrungen mit einer Hüfttotalendoprothese aus Biokeramik. Med Orthop Techn 95:162–164
Salzer M, Zweymüller K, Locke H, Plenk H Jr, Punzet G (1975) Biokeramische Endoprothesen. Med Orthop Techn 95:40–45
Willert HG (1973) Tissue reactions around joint implants and bone cement. In: Chapchal G (ed) Arthroplasty of the hip. Thieme, Stuttgart
Willert HG, Puls P (1972) Die Reaktion des Knochens auf Knochenzement bei der Allo-Arthroplastik der Hüfte. Arch Orthop Unfallchir 72:33
Willert HG, Semlitsch M (1974) Kapselreaktionen bei Gelenkprothesen. Schweizerisch-Niederländische Orthopädie-Tagung, Lausanne
Willert HG, Semlitsch M (1976) Kunststoffe als Implantatwerkstoffe. Med Orthop Techn 4:94
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1984 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Mittelmeier, H. (1984). Total Hip Replacement with the Autophor Cement-Free Ceramic Prosthesis. In: Morscher, E. (eds) The Cementless Fixation of Hip Endoprostheses. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-69006-8_37
Download citation
DOI: https://doi.org/10.1007/978-3-642-69006-8_37
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-69008-2
Online ISBN: 978-3-642-69006-8
eBook Packages: Springer Book Archive