Abstract
The outstanding chemical stability and tribologic properties of polymers have favored their introduction as implant materials. In 1946 the Judet Bros. [5] introduced polymethylmethacrylate as a material for femoral endoprostheses. In 1958 Charnley used polytetrafluoroethylene (Teflon) for an acetabular prosthesis which was cemented into place with cold-curing polymethylmethacrylate. When the Teflon showed an unacceptable degree of wear, Charnley [2, 3] introduced high-density polyethylene as an alternative material for acetabular prostheses.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Bourgeois R, Wagner J, Burny F (1973) Determination des propriétés mécaniques locales des os longs a l’aide de micro-éprouvettes. Acta Orthop Belg[Suppl] 139:25
Charnley J (1966) Total prosthetic replacement of the hip joint using a socket of high density polyethylene. Center for hip surgery, Wrightington Hospital, publication 1
Charnley J (1979) Low friction arthroplasty of the hip. Springer, Berlin Heidelberg New York
Geret V, Rahn BA, Mathys R etal. (1979) A method for testing tissue tolerance for improved quantitative evaluation through reduction of relative motion at the implant tissue interface. In: Winter G (ed) Advances in biomaterials. Wiley, New York, p 351
Judet J, Judet R (1950) The use of an artificial femoral head for arthroplasty of the hip joint. J Bone Joint Surg [Br] 32:166
Mathys R (1973) Stand der Verwendung von Kunststoffen für künstliche Gelenke. Aktuel Traumatol 3:253
Mathys R sen, Mathys R jun (1974) Die Grenzflächen (Metall-Metall, Metall-Kunststoff, Kunststoff-Kunststoff. In: Hartmann F (Hrsg) Biopolymere und Biomechanik von Bindegewebssystemen. Springer, Berlin Heidelberg New York S 401
Morscher E, Mathys R (1974) La prothèse totale de hanche isoélastique fixée sans ciment. Premiers résultats cliniques. Acta Orthop Belg 40:639
Morscher E, Mathys R (1975) Erste Erfahrungen mit einer zementlosen isoelastischen Totalprothese der Hüfte. Orthop. 113/4:745
Morscher E, Mathys R, Henche HR (1976) Isoelastic endoprosthesis A new concept in artificial joint replacement. In: Schaldach M (ed) Engineering in medicine, vol 2. Advances in hip and knee joint technology. Springer, Berlin Heidelberg New York
Schnabel W (1981) Polymer Degradation. Hanser, München Wien
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1984 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Mathys, R., Mathys, R. (1984). The Use of Polymers for Endoprosthetic Components. In: Morscher, E. (eds) The Cementless Fixation of Hip Endoprostheses. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-69006-8_12
Download citation
DOI: https://doi.org/10.1007/978-3-642-69006-8_12
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-69008-2
Online ISBN: 978-3-642-69006-8
eBook Packages: Springer Book Archive