Skip to main content

Analysis of Microbiology Test of Air-Conditioning System in Severe Cold Area

  • Conference paper
  • First Online:
Proceedings of the 8th International Symposium on Heating, Ventilation and Air Conditioning

Part of the book series: Lecture Notes in Electrical Engineering ((LNEE,volume 261))

  • 2807 Accesses

Abstract

Central air-conditioning system of Liaoning Provincial Museum has been taken as the target to study microbiology contamination since it is a typical public building. Three AHUs that conduct with different functional areas were considered as testing object in the museum, including constant temperature and humidity AHU B1, B2, and B3. Using microbiological method, six levels of impingement air microorganism sampler, fluorescent optical microscope, high-pressure steam sterilization pot, thermostatic incubator, thermostatic oven, biochemical incubator, and testing instruments are selected to test dust and air, which contain microbial organisms in the AHUs. Results show that the average product dust of the museum is 12.36 g/m2; the dust contains bacterial concentration in the microbiological is 85.2 × 104 cfu/m2, the air contains bacterial concentration in the microbiological is 568.19 cfu/m3, and the fungus concentration is 938.37 cfu/m3; the advantage strains in microbiologic is gram-positive bacterium; advantage strains in fungus is penicillium, aspergillums, branch spore mold.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  1. Nanqi R, Fang M et al (2002) Microbiology of environmental engineering. Harbin Institute of Technology Press, Harbin

    Google Scholar 

  2. The ministry of health of the People’s Republic of China (2006) Public centralized air ventilation system health standards. Beijing. Issued by the ministry of health supervision, No. 58

    Google Scholar 

Download references

Acknowledgments

This research was supported by The Natural Science Foundation of Liaoning (20101088). This project was funded by Scientific and Technical Fund Project Subsidy of Shenyang City (F11-264-1-17)

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Guohui Feng .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Li, H., Li, B., Feng, G., Cheng, P., Tang, C. (2014). Analysis of Microbiology Test of Air-Conditioning System in Severe Cold Area. In: Li, A., Zhu, Y., Li, Y. (eds) Proceedings of the 8th International Symposium on Heating, Ventilation and Air Conditioning. Lecture Notes in Electrical Engineering, vol 261. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-39584-0_52

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-39584-0_52

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-39583-3

  • Online ISBN: 978-3-642-39584-0

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics