Abstract
Human skin, which mainly consists of epidermis, dermis and hypodermis, is the largest organ of a human body. It has a lot of roles, for example, protection function, moisture maintenance function and sensory function. Moreover, it becomes a parameter for estimation of the health condition and beauty, because the skin is the outermost layer of a human body. At present, ocular inspection and palpation are generally used for detection of human skin condition such as surface appearance, and extensibility. Ocular inspection and palpation are important diagnosis procedures to examine patient’s skin condition quickly. However, it is difficult to quantify an evaluation by these diagnosis procedures, because it is very subjective. A development of handy method in order to evaluate the skin condition objectively is craved to dermatologists, and cosmetic industries. So far, various methods of evaluating skin condition objectively have been developed. However, these methods are substitutions of ocular inspection, or only measure some specific physical parameters of skin such as elasticity.
In this paper, the sensor that can measure various parts of human body in various conditions is developed. The polyvinylidene fluoride (PVDF) film, that is a kind of piezoelectric materials, is used as the sensory receptor in the sensor system. The functionality and signal processing of the sensor system are investigated by measurement of 15 kinds of artificial skin models, which are made of silicone rubber with different elasticity and roughness. Finally, the clinical test for human skin is conducted using the sensor system. Skin of medial forearm and base of thumb of 6 subjects are measured by the sensor. The obtained results show that two parameters calculated from the sensor output correspond to the subjective evaluations of extensibility and smoothness of the skin.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
H. Tagami, Perspective and prospective views of bioengineering of the skin, Fragrance J. 10, (1993), 11–15.
M. Egawa, M. Oguri, T. Hirao, M. Takahashi, M. Miyakawa, The evaluation of skin friction using a frictional feel analyzer, Skin Res. Technol. 8, (2002), 41–51.
A.A. Koudine, M. Barquins, Ph. Anthoine, L. Aubert, J.L. Leveque, Frictional properties of skin: proposal of a new approach, Int. J. Cosmet. Sci. 22, (2000), 11–20.
P. Corcuff, J.L. Leveque, Skin surface replica image, in: J. Serup, G.B.E. Jemec (Eds.), Analysis of Furrows and Wrinkles: Handbook of Non-Invasive Methods and the Skin, CRC Press, (1995), 89–96.
M. Rohr, K. Schrader, Topometry of human skin (FOITS), SOFW J. 2, (1998), 52–59.
M. Tanaka, Development of tactile sensor for monitoring skin conditions, J. Mater. Process. Technol. 108, (2001), 253–256.
M. Tanaka, J.L. Leveque, H. Tagami, K. Kikuchi, S. Chonan, The “Haptic Finger”-a new device for monitoring skin condition, Skin Res. Technol. 9, (2003), 131–136.
M. Tanaka, H. Sugiura, J.L. Leveque, H. Tagami, K. Kikuchi and S. Chonan, Active haptic sensation for monitoring skin conditions, J. Mater. Process. Technol. 161, (2005), 199–203.
D. Tsuchimi, T. Okuyama, M. Tanaka, Development of a Haptic Sensor System for Monitoring Human Skin Conditions (in Japanese), Proc. The 20th Symposium on Electromagnetics and Dynamics, (2008), 493–496.
S. W. Jacob and C. A. Francone. Structure and Function in Man. Saunders Philadelphia, (1974).
Ikohagi Toshiaki. Basic of Pressure Instrumentation of PVDF, JSME, Tokyo, (1994).
T. Maeno, K. Kobayashi, and N. Yamazaki. Relationship between the structure of human finger tissue and the location of tactile receptors. Bulletin of JSME International Journal, Vol. 41, No. 1C, (1998), 94–100.
Mami Tanaka, Jun Hiraizumi, Jean Luc Leveque, Seiji Chonan, Haptic sensor for monitoring skin conditions, International Journal of Applied Electromagnetics and Mechanics, 14, (2002), 397–404.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2009 International Federation of Medical and Biological Engineering
About this paper
Cite this paper
Tsuchimi, D., Okuyama, T., Tanaka, M. (2009). Development of a Haptic Sensor System for Monitoring Human Skin Conditions. In: Lim, C.T., Goh, J.C.H. (eds) 13th International Conference on Biomedical Engineering. IFMBE Proceedings, vol 23. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-92841-6_556
Download citation
DOI: https://doi.org/10.1007/978-3-540-92841-6_556
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-92840-9
Online ISBN: 978-3-540-92841-6
eBook Packages: EngineeringEngineering (R0)