Abstract
Left ventricular dysfunction was detected by bioimpedance measurement in patients with coronary artery disease during exercise bicycle test. The impedance cardiography gave the opportunity to monitor haemodynamic trends parameters. The aim of the study was to evaluate the haemodynamic changes during an exercise test in patients after coronary artery revascularisation. Material and Methods: 30 consecutive patients (age 60±9 y.) included into the cardiac rehabilitation program were divided into 2 groups; EF<50% (6 patients) and EF>50% (24 patients). Routine bicycle exercise tolerance test (EET) was performed simultaneously with four-electrode impedance cardiogram. ECG, blood pressure, Thoracic Impedance and the first derivative dz/dt were recorded. Stroke volume (SV), cardiac output, contractility indices (HI, ACCI), vascular peripheral resistance were calculated for each cardiac evolution. Trends of the parameters were analysed. Results: In patients with EF<50% the 3 SV trend patterns were observed. SV decreased 1.5 minute before the exercise time limit in 2 patients. SV was in the same level in 2 and increased slowly only during the first two steps in 2 ones.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Kottke F.J., Kubicek W.G., Ollson M.E. 1973 Evaluation of cardiac competence during rehabilitation following myocardial infarction. Israel J Med Sci 9(5):568-577.
Denniston J.C., Maher J.T., Reeves J.C., Cymerman J.C., Grover R.F. (1976) Measurement of cardiac output by electrical impedance at rest and during exercise. J Appl Phys 40(1):91-95.
Balasubramanian V., Hoon R.S. (1976) Changes in thoracic electrical impedance during submaximal treadmill exercise in patints with ischemic heart disease - A preliminary report. Am Heart J 91(1):43-49.
Siebert J. Bioimpedance measurement of hemodynamic response during an exercise test in patientrs with coronary artery disease. 12th European Conference of the International Society of noninvasive Cardiology Varese, Italy, 20-22 October 1994, Congress Book 65.
Breinstein DP (1986) A new stroke volume equation for thoracic electrical Bioimpedance: theory and rationale. Crit Care Med 14:904-909.6.
Scherhag A, Kaden J.J, Kentschke E, Sueselbeck T, Borggrefe M. Comparison of impedance cardiography and thermodilution-derived measurements of stroke volume and cardiac output at rest and during exercise testing.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2007 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Siebert, J., Trzeciak, B., Zielińska, D., Bakuła, S. (2007). Measurement of haemodynamic response during exercise test by impedance cardiography method in patients with coronary artery disease. In: Scharfetter, H., Merwa, R. (eds) 13th International Conference on Electrical Bioimpedance and the 8th Conference on Electrical Impedance Tomography. IFMBE Proceedings, vol 17. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-73841-1_148
Download citation
DOI: https://doi.org/10.1007/978-3-540-73841-1_148
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-73840-4
Online ISBN: 978-3-540-73841-1
eBook Packages: EngineeringEngineering (R0)