Abstract

This paper presents the application of an inhouse developed Monte Carlo Radiotherapy Simulator (MCRTS) to carry out complex radiotherapy investigations: Image Guided Radiotherapy (IGRT) with Cone-Beam Computed Tomography (CBCT) implementation and protection of irregular volume during tumor treatment. For the purposes of these simulation studies the MCRTS code has been additionally improved to include graphical features that facilitate the tumor delineating. A PC cluster with 24 dual-core processors nodes, running Linux operating system, is built to accelerate the calculations. Investigations of using megavoltage CBCT for tissue localization show that this technique could be used primarily to patient treatment for alignment purposes, using bony structures or air cavities. The feasibility study of shielding an irregular volume based on custom shielding filters designed by MCRTS demonstrates promising results by means of level of protection.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

References

  1. Bliznakova K, Kolitsi Z, Pallikarakis N (2004) A Monte Carlo based software tool for radiotherapy investigations. Nucl. Instr. Meth. B 222: 445–461

    Article  Google Scholar 

  2. Ivanova T, Bliznakova K, Pallikarakis N (2006) Simulation studies of field shaping in rotational radiation therapy. Med. Phys. 33(11): 4289–4298

    Article  Google Scholar 

  3. Messaris G, Kolitsi Z, Badea C, Pallikarakis N (1999) Threedimensional localization based on projectional and tomographic image correlation: an application for digital tomosynthesis. Med. Eng. & Phys. 21:101–109

    Article  Google Scholar 

  4. Bliznakova K, Buliev I, Bliznakov Z (2006) Monte Carlo radiotherapy simulator implemented on a distributed system. 5th European Symposium on Biomedical Engineering, In proceedings, Patras, Greece, 2006

    Google Scholar 

  5. Soimu D, Pallikarakis N (2004) Circular isocentric cone-beam trajectories for 3D image reconstructions using FDK algorithm. MEDICON 2004, In proceedings, Naples, Italy, 2004

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2007 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Bliznakova, K., Soimu, D., Bliznakov, Z., Pallikarakis, N. (2007). Monte Carlo Radiotherapy Simulator: Applications and Feasibility Studies. In: Jarm, T., Kramar, P., Zupanic, A. (eds) 11th Mediterranean Conference on Medical and Biomedical Engineering and Computing 2007. IFMBE Proceedings, vol 16. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-73044-6_240

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-73044-6_240

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-73043-9

  • Online ISBN: 978-3-540-73044-6

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics