Skip to main content

Fatigue Loading Tests of Concrete Railway Sleepers

  • Conference paper
  • First Online:
High Tech Concrete: Where Technology and Engineering Meet

Abstract

In fatigue loading tests, unused Finnish concrete railway sleepers of type B97 and BP99 were loaded. The purpose of the loading tests was to analyse the fatigue properties of the sleepers and the effect of fatigue on their stiffness. The significance of cracks was also estimated. The load levels were chosen so that it was possible to estimate the significance of fatigue in actual use. A total of 11 fatigue loading tests were run. Eight targeted the rail seat section and three the centre. One sleeper was also loaded only statically to serve as a reference. In fatigue loading tests sleeper specimens were subjected to 200,000 loading cycles with standard load, after which they were loaded statically to failure. Sleepers in rail seat section tests failed at under 200,000 cycles when the loading level was 195 kN or higher. A fatigue model depicting the relationship between the stress level of the sleeper and the number of loading cycles it is subjected to was developed based on the results of the fatigue loading tests. The fatigue limit determined based on the loading tests and the calculated limit state of crack formation were clearly higher than the bending moments measured in field tests. Consequently, deterioration of the railway sleepers under a traffic load and due to fatigue is highly unlikely.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 329.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Kerokoski, O., Nurmikolu, A. Rantala, T.: Loading tests of concrete monoblock railway sleepers. In: Nordic Concrete Research, vol. 45, pp. 1–14. Nordic Concrete Federation (2012). http://nordicconcrete.net/ncr-no-45-20121/. Accessed 21 Nov 2016

  2. Kerokoski, O., Rantala, T., Köliö, A., Nurmikolu, A.: Betoniratapölkyn rakenteellinen toiminta ja vaurioitumismekanismit. Ratapölkyn mekaanisen toiminnan ja rapautumisen kokeellinen ja laskennallinen arviointi. Liikenneviraston tutkimuksia ja selvityksiä 37/2013 (2013). (in Finnish). http://www2.liikennevirasto.fi/julkaisut/pdf3/lts_2013-37_betoniratapolkyn_rakenteellinen_web.pdf. Accessed 21 Nov 2016

  3. Ratahallintokeskus: Esijännitetyt betoniratapölkyt: Betoniratapölkkyjen tekniset toimitusehdot. Ratahallintokeskus, 1942/042/2008 (2008). (in Finnish). http://www2.liikennevirasto.fi/julkaisut/pdf4/rhk_esijannitetyt_betoniratapolkyt.pdf. Accessed 21 Nov 2016

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Olli Kerokoski .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer International Publishing AG

About this paper

Cite this paper

Rantala, T., Kerokoski, O., Nurmikolu, A., Laaksonen, A. (2018). Fatigue Loading Tests of Concrete Railway Sleepers. In: Hordijk, D., Luković, M. (eds) High Tech Concrete: Where Technology and Engineering Meet. Springer, Cham. https://doi.org/10.1007/978-3-319-59471-2_166

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-59471-2_166

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-59470-5

  • Online ISBN: 978-3-319-59471-2

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics