Single Cell Electrical Characterization Techniques

  • Reference work entry
  • First Online:
Handbook of Electroporation

Abstract

In this chapter the possibility to electrically characterize the electroporation of single cells is discussed. During the electroporation process, the application of pulsed electric field (Chap. 59, “Transmembrane Voltage Induced by Applied Electric Fields”) leads to the partial permeabilization of the cell membrane, opening access to the cytoplasmic compartment for drug delivery, for instance. The electric impedance of the cell is modified by such a treatment. Impedance measurement can thus be employed to characterize the permeabilization effect, on a given angular frequencies range, which leads to an impedance spectrum. The impedance spectrum measurement can be achieved even at the level of single cells. In that case, the distance between the detection microelectrodes and the cell must be considered in order to achieve a satisfactory sensitivity. In addition, when considering the impedance measurement of cells flowing through a microfluidic channel, fast detection is also required, as the cell is present between the measurement electrodes only for a short while. A specific strategy must then be employed to achieve such goal. In this case, instead of screening the whole frequencies spectrum, a few set of frequencies should be selected and mixed to be simultaneously injected prior to synchronous detection. Another way to assess the single cell impedance is the use of indirect methods based on the mechanical behavior of cells that polarize under the application of a stationary or propagative electrical field. In particular, electrorotation experiment provides the electrical characterization of the cell, which is dependent of its level of permeabilization, after the application of electrical field pulses. When such approach is used, the vicinity of electrodes is less critical as the main requirement lays on the homogeneity of the rotating electrical field. Finally, the possibility to focus the electroporation at the subcellular level is discussed in the chapter. Indeed, the use of micro- or nanotechnology permits to localize spatially the electroporation on a tiny portion of the membrane of single cells. Adherent cells can be locally electroporated, using nanosized electrodes, subsequently used to monitor the intracellular potential.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 1,799.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 1,999.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  • Brüggemann A, Stoelzle S, George M, Behrends JC, Fertig N (2006) Microchip technology for automated and parallel patch-clamp recording. Small 2(7):840–846

    Article  Google Scholar 

  • Bürgel SC, Escobedo C, Haandbæk N, Hierlemann A (2015) On-chip electroporation and impedance spectroscopy of single-cells. Sens Actuators B 210:82–90

    Article  Google Scholar 

  • Čemažar J, Miklavčič D, Kotnik T (2013) Microfluidic devices for manipulation, modification and characterization of biological cells in electric fields–a review. J Microelectron Electron Compon Mater 43(3):143–161

    Google Scholar 

  • Dalmay C, De Menorval M, Francais O, Mir L, Le Pioufle B (2012) A microfluidic device with removable packaging for the real time visualisation of intracellular effects of nanosecond electrical pulses on adherent cells. Lab Chip 12(22):4709–4715

    Article  Google Scholar 

  • Fertig N, George M, Klau M, Meyer C, Tilke A, Sobotta C, Blick RH, Behrends JC (2003) Microstructured apertures in planar glass substrates for ion channel research. Receptors Channels 9(1):29–40

    Article  Google Scholar 

  • Gawad S, Schild L, Renaud P (2001) Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing. Lab Chip 1(1):76–82

    Article  Google Scholar 

  • Haandbæk N, Bürgel SC, Heer F, Hierlemann A (2014) Characterization of subcellular morphology of single yeast cells using high frequency microfluidic impedance cytometer. Lab Chip 14(2):369–377

    Article  Google Scholar 

  • Hoffman R, Britt W (1979) Flow-system measurement of cell impedance properties. J Histochem Cytochem 27(1):234–240

    Article  Google Scholar 

  • Holmes D, Pettigrew D, Reccius CH, Gwyer JD, van Berkel C, Holloway J, Davies DE, Morgan H (2009) Leukocyte analysis and differentiation using high speed microfluidic single cell impedance cytometry. Lab Chip 9(20):2881–2889

    Article  Google Scholar 

  • Huang Y, Rubinsky B (1999) Micro-electroporation: improving the efficiency and understanding of electrical permeabilization of cells. Biomed Microdevices 2(2):145–150

    Article  Google Scholar 

  • Huang Y, Rubinsky B (2001) Microfabricated electroporation chip for single cell membrane permeabilization. Sens Actuators A: Phys 89(3):242–249

    Article  Google Scholar 

  • Huang Y, Holzel R, Pethig R, Wang XB (1992) Differences in the ac electrodynamics of viable and non-viable yeast cells determined through combined dielectrophoresis and electrorotation studies. Phys Med Biol 37(7):1499

    Article  Google Scholar 

  • Jones TB (2005) Electromechanics of particles. Cambridge University Press, Cambridge

    Google Scholar 

  • Khine M, Lau A, Ionescu-Zanetti C, Seo J, Lee LP (2005) A single cell electroporation chip. Lab Chip 5(1):38–43

    Article  Google Scholar 

  • Khine M, Ionescu-Zanetti C, Blatz A, Wang LP, Lee LP (2007) Single-cell electroporation arrays with real-time monitoring and feedback control. Lab Chip 7(4):457–462

    Article  Google Scholar 

  • Martinsen OG, Grimnes S (2011) Bioimpedance and bioelectricity basics. Academic Press, London

    Google Scholar 

  • Maxwell JC (1881) A treatise on electricity and magnetism, vol 1. Clarendon, Oxford

    MATH  Google Scholar 

  • Morgan H, Green N (2003) AC electrokinetics: colloids and nanoparticles. Research Studies Press, Philadelphia

    Google Scholar 

  • Morgan H, Sun T, Holmes D, Gawad S, Green NG (2006) Single cell dielectric spectroscopy. J Phys D Appl Phys 40(1):61

    Article  Google Scholar 

  • Neher E, Sakmann B, Steinbach JH (1978) The extracellular patch clamp: a method for resolving currents through individual open channels in biological membranes. Pflugers Arch 375(2):219–228

    Article  Google Scholar 

  • Pavlin M, Kandušer M, Reberšek M, Pucihar G, Hart FX, Magjarevićcacute R, Miklavčič D (2005) Effect of cell electroporation on the conductivity of a cell suspension. Biophys J 88(6):4378–4390

    Article  Google Scholar 

  • Pohl HA (1958) Some effects of nonuniform fields on dielectrics. J Appl Phys 29(8):1182–1188

    Article  Google Scholar 

  • Schoenbach KH, Beebe SJ, Buescher ES (2001) Intracellular effect of ultrashort electrical pulses. Bioelectromagnetics 22(6):440–448

    Article  Google Scholar 

  • Sun T, Morgan H (2010) Single-cell microfluidic impedance cytometry: a review. Microfluid Nanofluid 8(4):423–443

    Article  Google Scholar 

  • Trainito CI, Français O, Le Pioufle B (2015) Monitoring the permeabilization of a single cell in a microfluidic device, through the estimation of its dielectric properties based on combined dielectrophoresis and electrorotation in situ experiments. Electrophoresis 36(9–10):1115–1122

    Article  Google Scholar 

  • Xie C, Lin Z, Hanson L, Cui Y, Cui B (2012) Intracellular recording of action potentials by nanopillar electroporation. Nat Nanotechnol 7(3):185–190

    Article  Google Scholar 

Download references

Acknowledgments

This work has benefited from the financial support of the LabeX LaSIPS (ANR-10-LABX-0040-LaSIPS) managed by the French National Research Agency under the “Investissements d’avenir” program (nANR-11-IDEX-0003-02) and COST TD1104, www.electroporation.net. The authors acknowledge project supports from ENS Cachan-Université Paris Saclay, Institut d’Alembert, and CNRS.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Bruno Le Pioufle .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2017 Springer International Publishing AG

About this entry

Cite this entry

Français, O., Le Pioufle, B. (2017). Single Cell Electrical Characterization Techniques. In: Miklavčič, D. (eds) Handbook of Electroporation. Springer, Cham. https://doi.org/10.1007/978-3-319-32886-7_15

Download citation

Publish with us

Policies and ethics