Skip to main content

Optical Coherence Tomography: Role in Percutaneous Coronary Intervention

  • Chapter
  • First Online:
Intraprocedural Imaging of Cardiovascular Interventions

Abstract

Optical coherence tomography (OCT) is an imaging modality that utilizes back-reflection of near-infrared light. Superior resolution intra-coronary imaging, including assessment of plaque morphology and characteristics as well as imaging stents and post-stent complications have made OCT a powerful research tool, and more recently a clinical tool for guidance of PCI. Visualization of coronary lesions with OCT and their characterization as lipid-rich, fibrous, or fibro-calcific plaque can influence percutaneous coronary intervention (PCI) procedural planning. OCT has contributed significantly to the understanding of culprit lesion pathophysiology in acute coronary syndromes (ACS). ACS culprit lesions have been categorized by OCT features as resulting from plaque rupture, calcific nodule, or plaque erosion. Finally, OCT has proven to be an ideal imaging modality for ensuring optimal results after PCI. OCT can be used to assess for appropriate stent expansion and apposition of the stent with the vessel wall, and is an effective modality for the detection and assessment of stent-edge dissection, incomplete stent apposition, and in-stent tissue protrusion. The resolution of OCT allows for detection and assessment of in-stent neointima proliferation and neoatherosclerosis. A demonstrated safe and effective research instrument, OCT has shown great potential in this clinical role as an adjunctive imaging modality for PCI.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 89.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 119.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 139.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  1. Huang D, Swanson EA, Lin CP, Schuman JS, Stinson WG, Chang W, et al. Optical coherence tomography. Science. 1991;254:1178–81.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  2. Herrero-Garibi J, Cruz-Gonzalez I, Parejo-Diaz P, Jang IK. Optical coherence tomography: its value in intravascular diagnosis today. Rev Esp Cardiol. 2010;63:951–62.

    Article  PubMed  Google Scholar 

  3. Suh WM, Seto AH, Margey RJ, Cruz-Gonzalez I, Jang IK. Intravascular detection of the vulnerable plaque. Circ Cardiovasc Imaging. 2011;4:169–78.

    Article  PubMed  Google Scholar 

  4. Barlis P, Gonzalo N, Di Mario C, Prati F, Buellesfeld L, Rieber J, Dalby MC, Ferrante G, Cera M, Grube E, et al. A multicentre evaluation of the safety of intracoronary optical coherence tomography. EuroIntervention. 2009;5:90–5.

    Article  PubMed  Google Scholar 

  5. Suter MJ, Nadkarni SK, Weisz G, et al. Intravascular optical imaging technology for investigating the coronary artery. J Am Coll Cardiol Img. 2011;4:1022–39.

    Article  Google Scholar 

  6. Low AF, Kawase Y, Chan YH, et al. In vivo characterization of coronary plaques with conventional grey-scale intravascular ultrasound: correlation with optical coherence tomography. EuroIntervention. 2009;4:626–32.

    Article  PubMed  PubMed Central  Google Scholar 

  7. Kawasaki M, Bouma BE, Bressner J, et al. Diagnostic accuracy of optical coherence tomography and integrated backscatter intravascular ultrasoundimages for tissue characterization of human coronary plaques. J Am Coll Cardiol. 2006;48:81–8.

    Article  PubMed  Google Scholar 

  8. Garcia-Garcia HM, Gonzalo N, Regar E, et al. Virtual histology and optical coherence tomography: from research to broad clinical application. Heart. 2009;95:132–1374.

    Article  Google Scholar 

  9. Kubo T, Imanishi T, Takarada S, et al. Assessment of culprit lesion morphology in acute myocardial infarction: ability of optical coherence tomography compared with intravascular ultrasound and coronary angioscopy. J Am Coll Cardiol. 2007;50:933–9.

    Article  PubMed  Google Scholar 

  10. Takano M, Jang IK, Inami S, et al. In vivo comparison of optical coherence tomography and angioscopy for the evaluation of coronary plaque charactistics. Am J Cardiol. 2008;101:471–6.

    Article  PubMed  Google Scholar 

  11. Kume T, Akasaka T, Kawamoto T, Okura H, Watanabe N, Toyota E, Neishi Y, Sukmawan R, Sadahira Y, Yoshida K. Measurement of the thickness of the fibrous cap by optical coherence tomography. Am Heart J. 2006;152(755):e751–4.

    Google Scholar 

  12. Raffel OC, Akasaka T, Jang IK. Cardiac optical coherence tomography. Heart. 2008;94:1200–10.

    Article  CAS  PubMed  Google Scholar 

  13. Jang IK, Tearney GJ, MacNeill B, Takano M, Moselewski F, Iftima N, Shishkov M, Houser S, Aretz HT, Halpern EF, et al. In vivo characterization of coronary atherosclerotic plaque by use of optical coherence tomography. Circulation. 2005;111:1551–5.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Kubo T, Takashi A, Shite J, et al. OCT compared with IVUS in a coronary lesion assessment. J Am Coll Cardiol Img. 2013;6:1095–104.

    Article  Google Scholar 

  15. Yonetsu T, Kakuta T, Lee T, Takahashi K, Yamamoto G, Iesaka Y, Fujiwara H, Isobe M. Impact of plaque morphology on creatine kinase-MB elevation in patients with elective stent implantation. Int J Cardiol. 2011;146:80–5.

    Article  PubMed  Google Scholar 

  16. Lee T, Kakuta T, Yonetsu T, Takahashi K, Yamamoto G, Iesaka Y, Fujiwara H, Isobe M. Assessment of echo-attenuated plaque by optical coherence tomography and its impact on post-procedural creatine kinase-myocardial band elevation in elective stent implantation. JACC Cardiovasc Interv. 2011;4:483–91.

    Article  PubMed  Google Scholar 

  17. Lee T, Yonetsu T, Koura K, Hishikari K, Murai T, Iwai T, Takagi T, Iesaka Y, Fujiwara H, Isobe M, et al. Impact of coronary plaque morphology assessed by optical coherence tomography on cardiac troponin elevation in patients with elective stent implantation. Circ Cardiovasc Interv. 2011;4:378–86.

    Article  CAS  PubMed  Google Scholar 

  18. Porto I, Di Vito L, Burzotta F, Niccoli G, Trani C, Leone AM, Biasucci LM, Vergallo R, Limbruno U, Crea F. Predictors of periprocedural (type IVa) myocardial infarction, as assessed by frequency-domain optical coherence tomography. Circ Cardiovasc Interv. 2012;5:89–96. S81–86.

    Article  CAS  PubMed  Google Scholar 

  19. Gonzalo N, Escaned J, Alfonso F, Nolte C, Rodriguez V, Jimenez- Quevedo P, Banuelos C, Fernandez-Ortiz A, Garcia E, Hernandez- Antolin R, et al. Morphometric assessment of coronary stenosis relevance with optical coherence tomography: a comparison with fractional flow reserve and intravascular ultrasound. J Am Coll Cardiol. 2012;59:1080–9.

    Article  PubMed  Google Scholar 

  20. Stefano GT, Bezerra HG, Attizzani G, Chamie D, Mehanna E, Yamamoto H, Costa MA. Utilization of frequency domain optical coherence tomography and fractional flow reserve to assess intermediate coronary artery stenoses: conciliating anatomic and physiologic information. Int J Cardiovasc Imaging. 2011;27:299–308.

    Article  PubMed  PubMed Central  Google Scholar 

  21. Garg S, Serruys PW. Coronary stents: current status. J Am Coll Cardiol. 2010;56(56):S1–42.

    Article  CAS  PubMed  Google Scholar 

  22. Choi SY, Witzenbichler B, Maehara A, Lansky AJ, Guagliumi G, Brodie B, et al. Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: a Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy. Circ Cardiovasc Interv. 2011;4(3):239–47.

    Article  PubMed  Google Scholar 

  23. Sonoda S, Morino Y, Ako J, Terashima M, Hassan AH, Bonneau HN, et al. Impact of final stent dimensions on long-term results following sirolimus-eluting stentimplantation: serial intravascular ultrasound analysis from the sirius trial. J Am Coll Cardiol. 2004;43(11):1959–63.

    Article  PubMed  Google Scholar 

  24. Hong MK, Mintz GS, Lee CW, Park DW, Park KM, Lee BK, et al. Late stent malapposition after drug-eluting stent implantation: an intravascular ultrasound analysis with long-term follow-up. Circulation. 2006;113(3):414–9.

    Article  CAS  PubMed  Google Scholar 

  25. Doi H, Maehara A, Mintz GS, Yu A, Wang H, Mandinov L, et al. Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS workhorse, long lesion, and direct stent trials. JACC Cardiovasc Interv. 2009;2(12):1269–75.

    Article  PubMed  Google Scholar 

  26. Fujii K, Carlier SG, Mintz GS, Yang YM, Moussa I, Weisz G, et al. Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study. J Am Coll Cardiol. 2005;45(7):995–8.

    Article  CAS  PubMed  Google Scholar 

  27. Song HG, Kang SJ, Ahn JM, Kim WJ, Lee JY, Park DW, et al. Intravascular ultrasound assessment of optimal stent area to prevent in-stent restenosis after zotarolimus-, everolimus-, and sirolimus-eluting stent implantation. Catheter Cardiovasc Interv. 2014;83(6):873–8.

    Article  PubMed  Google Scholar 

  28. Kume T, Okura H, Miyamoto Y, Yamada R, Saito K, Tamada T, et al. Natural history of stent edge dissection, tissue protrusion and incomplete stent apposition detectable only on optical coherence tomography after stent implantation: preliminary observation. Circ J. 2012;76:698–703.

    Article  PubMed  Google Scholar 

  29. Gonzalo N, Serruys PW, Okamura T, Shen ZJ, Garcia-Garcia HM, Onuma Y, et al. Relation between plaque type and dissections at the edges after stent implantation: an optical coherence tomography study. Int J Cardiol. 2011;150:151–5.

    Article  PubMed  Google Scholar 

  30. Gonzalo N, Serruys PW, Okamura T, Shen ZJ, Onuma Y, Garcia-Garcia HM, et al. Optical coherence tomography assessment of the acute effects of stent implantation on the vessel wall: a systematic quantitative approach. Heart. 2009;95:1913–9.

    Article  CAS  PubMed  Google Scholar 

  31. Kubo T, Imanishi T, Kibata H, Kuroi A, Ueno S, Yamano T, et al. Comparison of vascular response after sirolimus-eluting stent implantation between patients with unstable and stable angina pectoris: a serial optical coherence tomography study. JACC Cardiovasc Imaging. 2008;1:475–84.

    Article  PubMed  Google Scholar 

  32. Soeda T, Uemura S, Park S-J, Jang Y, Lee S, Vergallo R, et al. Incidence and Clinical Significance of Poststent Optical Coherence Tomography Findings: One-Year Follow-Up Study From a Multicenter Registry. Circulation. 2015;132:1020–9.

    Google Scholar 

  33. Bouma BE, Tearney GJ, Yabushita H, Shishkov M, Kauffman CR, DeJoseph Gauthier D, et al. Evaluation of intracoronary stenting by intravascular optical coherence tomography. Heart. 2003;89:317–20.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  34. Tanigawa J, Barlis P, Dimopoulos K, Dalby M, Moore P, Di Mario C. The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography. Int J Cardiol. 2009;134(2):180–8.

    Article  PubMed  Google Scholar 

  35. Fujino Y, Bezerra HF, Attizzani GF, Wang W, Yamamoto H, Chamié D, et al. Frequency-domain optical coherence tomography assessment of unprotected left main coronary artery disease-a comparison with intravascular ultrasound. Catheter Cardiovasc Interv. 2013;82(3):E173–83.

    Article  PubMed  Google Scholar 

  36. Jang IK, Tearney G, Bouma B. Visualization of tissue prolapse between coronary stent struts by optical coherence tomography: comparison with intravascular ultrasound. Circulation. 2001;104:2754.

    Article  CAS  PubMed  Google Scholar 

  37. Kawamori H, Shite J, Shinke T, Otake H, Matsumoto D, Nakagawa M, et al. Natural consequence of post-intervention stent malapposition, thrombus, tissue prolapse, and dissection assessed by optical coherence tomography at mid-term follow-up. Eur Heart J Cardiovascular Imaging. 2013;14(9):865–75.

    Article  Google Scholar 

  38. Cook S, Wenaweser P, Togni M, Billinger M, Morger C, Seiler C, et al. Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation. 2007;115:2426–34.

    Article  CAS  PubMed  Google Scholar 

  39. Sawada T, Shite J, Shinke T, Tanino Y, Ogasawara D, Kawamori H, et al. Very late thrombosis of sirolimus-eluting stent due to late malapposition: serial observations with optical coherence tomography. J Cardiol. 2008;52:290–5.

    Article  PubMed  Google Scholar 

  40. Guagliumi G, Sirbu V, Musumeci G, Gerber R, Biondi-Zoccai G, Ikejima H, et al. Examination of the in vivo mechanisms of late drug-eluting stent thrombosis: findings from optical coherence tomography and intravascular imaging. JACC Cardiovasc Interv. 2012;5:12–20.

    Article  PubMed  Google Scholar 

  41. Gutierrez-Chico JL, Regar E, Nuesch E, Okamura T, Wykrykowska J, di Mario C, Windecker S, van Es GA, et al. Delayed coverage in malapposed and side-branch stents: in vivo assessment with optical coherence tomography. Circulation. 2011;124:612–23.

    Article  CAS  PubMed  Google Scholar 

  42. Chamié D, Bezerra HG, Attizzani GF, Yamamoto H, Kanaya T, Stefano GT, et al. Incidence, predictors, morphological characteristics, and clinical outcomes of stent edge dissections detected by optical coherence tomography. JACC Cardiovasc Interv. 2013;6(8):800–13.

    Article  PubMed  Google Scholar 

  43. De Cock D, Bennett J, Ughi GJ, Dubois C, Sinnaeve P, Dhooge J, et al. Healing course of acute vessel wall injury after drug-eluting stent implantation assessed by optical coherence tomography. Eur Heart J Cardiovasc Imaging. 2014;15(7):800–9.

    Article  PubMed  Google Scholar 

  44. Imola F, Occhipinti M, Biondi-Zoccai G, Di Vito L, Ramazzotti V, Manzoli A, et al. Association between proximal stent edge positioning on atherosclerotic plaques containing lipid pools and postprocedural myocardial infarction (from the CLI-POOL Study). Am J Cardiol. 2013;111:526–31.

    Article  PubMed  Google Scholar 

  45. Kim JS, Hong MK, Fan C, Kim TH, Shim JM, Park SM, et al. Intracoronary thrombus formation after drug-eluting stents implantation: optical coherence tomographic study. Am Heart J. 2010;159(2):278–83.

    Article  CAS  PubMed  Google Scholar 

  46. Gonzalo N, Serruys PW, Okamura T, van Beusekom HM, Garcia-Garcia HM, von Soest G, et al. Optical coherence tomography patterns of stent restenosis. Am Heart J. 2009;158:284–93.

    Article  PubMed  Google Scholar 

  47. Nagai H, Ishibashi-Ueda H, Fujii K. Histology of highly echolucent regions in optical coherence tomography images from two patients with sirolimus-eluting stent restenosis. Catheter Cardiovasc Interv. 2010;75:961–3.

    PubMed  Google Scholar 

  48. Kume T, Akasaka T, Kawamoto T, Watanabe N, Toyota E, Sukmawan R, et al. Visualization of neointima formation by optical coherence tomography. Heart J. 2005;46:1133–6.

    Google Scholar 

  49. Nakazawa G, Otsuka F, Nakano M, Vorpahl M, Yazdani SK, Ladich E, et al. The pathology of neoatherosclerosis in human coronary implants bare-metal and drug-eluting stents. J Am Coll Cardiol. 2011;57(11):1314–22.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  50. Takano M, Yamamoto M, Inami S, Murakami D, Ohba T, Seino Y, Mizuno K. Appearance of lipid-laden intima and neovascularization after implantation of bare-metal stents extended late-phase observation by intracoronary optical coherence tomography. J Am Coll Cardiol. 2009;55(1):26–32.

    Article  PubMed  Google Scholar 

  51. Hou J, Qi H, Zhang M, Ma L, Liu H, Han Z, et al. Development of lipid-rich plaque inside bare metal stent: possible mechanism of late stent thrombosis? An optical coherence tomography study. Heart. 2010;96(15):1187–90.

    Article  PubMed  Google Scholar 

  52. Yamaji K, Inoue K, Nakahashi T, Noguchi M, Domei T, Hyodo M, et al. Bare metal stent thrombosis and in-stent neoatherosclerosis. Circulation. 2012;5:47–54.

    PubMed  Google Scholar 

  53. Kim JS, Kato K, Kim SJ, Xing L, Yeh RW, et al. Comparison of incidence and time course of neoatherosclerosis between bare metal stents and drug-eluting stents using optical coherence tomography. Am J Cardiol. 2012;110(7):933–9.

    Article  PubMed  Google Scholar 

  54. Serruys PW, Onuma Y, Dudek D, Smits PC, Koolen J, Chevalier B, et al. Evaluation of the second generation of a bioresorbable everolimus-eluting vascular scaffold for the treatment of de novo coronary artery stenosis 12-month clinical and imaging outcomes. J Am Coll Cardiol. 2011;58:1578–87.

    Article  CAS  PubMed  Google Scholar 

  55. Serruys PW, Ormiston JA, Onuma Y, Regar E, Gonzalo N, Garcia-Garcia HM, et al. A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods. Lancet. 2009;373:897–910.

    Article  CAS  PubMed  Google Scholar 

  56. Bourantas CV, Serruys PW, Nakatani S, Zhang YJ, Farooq V, Diletti R, et al. Bioresorbable vascular scaffold treatment induces the formation of neointimal cap that seals the underlying plaque without compromising the luminal dimensions: a concept based on serial optical coherence tomography data. EuroIntervention. 2015;11:746–56.

    Google Scholar 

  57. Okamura T, Onuma Y, Garcia-Garcia HM, Regar E, Wykrzkowska JJ, Koolen J, et al. 3-dimensional optical coherence tomography assessment of jailed side branches by bioresorbable vascular scaffolds: a proposal for classification. J Am Coll Cardiol Intv. 2010;3:836–44.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ik-Kyung Jang MD, PhD .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer International Publishing Switzerland

About this chapter

Cite this chapter

Ain, D.L., Gallagher, R., Jang, IK. (2016). Optical Coherence Tomography: Role in Percutaneous Coronary Intervention. In: Picard, M., Passeri, J., Dal-Bianco, J. (eds) Intraprocedural Imaging of Cardiovascular Interventions. Springer, Cham. https://doi.org/10.1007/978-3-319-29428-5_12

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-29428-5_12

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-29426-1

  • Online ISBN: 978-3-319-29428-5

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics