Abstract
Chemical exchange saturation transfer (CEST) is an MRI method that provides insights on the metabolic level. Several metabolite effects appear in the CEST spectrum. These effects are isolated by Lorentzian curve fitting. The separation of CEST effects suffers from the inhomogeneity of the saturation field B1. This leads to inhomogeneities in the associated metabolic maps. Current B1 correction methods require at least two sets of CEST-spectra. This at least doubles the acquisition time. In this study, we investigated the use of an unsupervised physics-informed conditional autoencoder (PICAE) to efficiently correct B1 inhomogeneity and isolate metabolic maps while using a single CEST scan. The proposed approach integrates conventional Lorentzian model into the conditional autoencoder and performs voxel-wise B1 correction and Lorentzian line fitting. The method provides clear interpretation of each step and is inherently generative. Thus, CEST-spectra and fitted metabolic maps can be created at arbitrary B1 levels. This is important because the B1 dispersion contains information about the exchange rates and concentration of metabolite protons, paving the way for their quantification. The isolated maps for tumor data showed a robust B1 correction and more than 25% increase in structural similarity index (SSIM) with gadolinium reference image compared to the standard interpolation-based method and subsequent Lorentzian curve fitting. This efficient correction method directly results in at least 50% reduction in scan time.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Chen, L.Q., Pagel, M.D.: Evaluating pH in the extracellular tumor microenvironment using CEST MRI and other imaging methods. Adv. Radiol. 2015, 25 (2015)
Dou, W., et al.: Chemical exchange saturation transfer magnetic resonance imaging and its main and potential applications in pre-clinical and clinical studies. Quant. Imaging Med. Surg. 9(10), 1747–1766 (2019)
Glang, F., et al.: Linear projection-based CEST parameter estimation. NMR Biomed. (2022). https://doi.org/10.1002/nbm.4697
Hunger, L., et al.: Deepcest 7 t: fast and homogeneous mapping of 7 t CEST MRI parameters and their uncertainty quantification. Magn. Reson. Med. 89, 1543–1556 (2023)
Lewerenz, J., Maher, P.: Chronic glutamate toxicity in neurodegenerative diseases-what is the evidence? Front. Neurosci. 9, 469 (2015)
Maier, A.K., Schebesch, F., Syben, C., Würfl, T., Steidl, S., Choi, J.H., Fahrig, R.: Precision learning: Towards use of known operators in neural networks. In: 2018 24th International Conference on Pattern Recognition (ICPR), pp. 183–188 (2017)
Maier, A.K., et al.: Learning with known operators reduces maximum error bounds. Nat. Mach. Intell. 1, 373–380 (2019)
Mcconnell, H.M.: Reaction rates by nuclear magnetic resonance. J. Chem. Phys. 28, 430–431 (1958)
Mennecke, A., et al.: 7 tricks for 7 t CEST: improving reproducibility of multi-pool evaluation provides insights into effects of age and early stage parkinson’s disease. NMR Biomed. 36(6), e4717 (2022)
Moré, J.J., Sorensen, D.C.: Computing a trust region step. Siam J. Sci. Stat. Comput. 4, 553–572 (1983)
Penney, G.P., Weese, J., Little, J.A., Desmedt, P., Hill, D.L.G., Hawkes, D.J.: A comparison of simularity measures for use in 2d–3d medical image registration. In: International Conference on Medical Image Computing and Computer-Assisted Intervention (1998)
Rosasco, L., de Vito, E., Caponnetto, A., Piana, M., Verri, A.: Are loss functions all the same? Neural Comput. 16, 1063–1076 (2004)
Sohn, K., Lee, H., Yan, X.: Learning structured output representation using deep conditional generative models. In: NIPS (2015)
Windschuh, J., et al.: Correction of b1-inhomogeneities for relaxation-compensated CEST imaging at 7 t. NMR in Biomed. 28, 529–537 (2015)
Zaiss, M., Jin, T., Kim, S.G., Gochberg, D.F.: Theory of chemical exchange saturation transfer MRI in the context of different magnetic fields. NMR Biomed. 35, e4789 (2022)
Zhou, J., Payen, J.F., Wilson, D.A., Traystman, R.J., van Zijl, P.C.M.: Using the amide proton signals of intracellular proteins and peptides to detect PH effects in MRI. Nature Med. 9, 1085–1090 (2003)
Zhu, J.Y., Park, T., Isola, P., Efros, A.A.: Unpaired image-to-image translation using cycle-consistent adversarial networks. In: 2017 IEEE International Conference on Computer Vision (ICCV), pp. 2242–2251 (2017)
van Zijl, P.C.M., Yadav, N.N.: Chemical exchange saturation transfer (CEST): what is in a name and what isn’t? Magn. Reson. Med. 65, 927–948 (2011)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2023 The Author(s), under exclusive license to Springer Nature Switzerland AG
About this paper
Cite this paper
Rajput, J.R. et al. (2023). Physics-Informed Conditional Autoencoder Approach for Robust Metabolic CEST MRI at 7T. In: Greenspan, H., et al. Medical Image Computing and Computer Assisted Intervention – MICCAI 2023. MICCAI 2023. Lecture Notes in Computer Science, vol 14227. Springer, Cham. https://doi.org/10.1007/978-3-031-43993-3_44
Download citation
DOI: https://doi.org/10.1007/978-3-031-43993-3_44
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-031-43992-6
Online ISBN: 978-3-031-43993-3
eBook Packages: Computer ScienceComputer Science (R0)