Abstract
A novel modality of ultrasound imaging known as elastography has been shown to improve cancer detection for women with dense breast tissue. However, the scanning procedure for this technique is often difficult for a human to perform in a consistent manner and could conceivably benefit from robot assistance. In this work, we present a novel robot-assisted probabilistic elasticity mapping algorithm which uses Gaussian filter techniques to produce elastograms and uncertainty maps. We demonstrate the proposed approach using a 7-DOF robot manipulator on a gelatin phantom designed to imitate the elasticity of human tissue. The results indicate the algorithm is capable of imaging a \({6.5\,\mathrm{\text {m}\text {m}}}\) lesion and reducing map uncertainty in the observable region.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Notes
- 1.
Some research reports numbers as high as 90%.
- 2.
A low PPV is synonomous to a high number of false positives.
- 3.
The transducer is limited to 128 lateral samples as opposed to thousands in the axial direction.
References
American Cancer Society: Breast cancer factors and figures 2017–2018 (2017). https://www.cancer.org/. Accessed 16 Feb 2018
Billings, S., Deshmukh, N., Kang, H.J., Taylor, R., Boctor, E.: System for robot-assisted real-time laparoscopic ultrasound elastography. In: Proceedings SPIE 8316 Medical Imaging 2012: Image-Guided Procedures, Robotic Interventions, and Modeling, p. 83161W (2012)
Cabrelli, L.C., Pelissari, P.I.B.G.B., Deana, A.M., Carneiro, A.A.O., Pavan, T.Z.: Stable phantom materials for ultrasound and optical imaging. Phys. Med. Biol. 62(2), 432–447 (2016)
Coffin, C.: Work-related musculoskeletal disorders in sonographers: a review of causes and types of injury and best practices for reducing injury risk. Rep. Med. Imag. 7, 15 (2014)
Cook, R.D., Malkus, D.S., Plesha, M.E., Witt, R.J.: Concepts and Applications of Finite Element Analysis. John Wiley & Sons Inc., New York (2007)
Doyley, M.M., Parker, K.J.: Elastography: general principles and clincial applications. Ultrasound Clin. 1(9), 11 (2014)
Doyley, M.M., Meaney, P.M., Bamber, J.C.: Evaluation of an iterative reconstruction method for quantitative elastography. Phys. Med. Biol. 45, 1521–1540 (2000)
Doyley, M.M., Bamber, J.C., Fuechsel, F., Bush, N.L.: A freehand elastographic imaging approach for clinical breast imaging: system development and performance evaluation. Ultrasound Med. Biol. 27(10), 1347–1357 (2001)
Evans, K., Roll, S., Baker, J.: Work-related musculoskeletal disorders (WRMSD) among registered diagnostic medical sonographers and vascular technologists: a representative sample. J. Diagn. Med. Sonography 25(6), 287–299 (2009)
Giovannini, M., et al.: Endoscopic ultrasound elastography for evaluation of lymph nodes and pancreatic masses: a multicenter study. World J. Gastroenterol. 15(13), 1587–1593 (2009)
Goswami, S., Ahmed, R., Doyley, M.M., McAleavey, S.A.: Nonlinear shear modulus estimation with bi-axial motion registered local strain. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 66(8), 1292–1303 (2019)
Hellgren, R., Dickman, P., Leifland, K., Saracco, A., Hall, P., Celebioglu, F.: Comparison of handheld ultrasound and automated breast ultrasound in women recalled after mammography screening. Acta Radiol. 58(5), 515–520 (2017)
Koutsourelakis, P.S.: A novel Bayesian strategy for the identification of spatially varying material properties and model validation: an application to static elastography. Int. J. Numer. Methods Eng. 91(3), 249–268 (2012)
Mandelson, M.T., et al.: Breast density as a predictor of mammographic detection: comparison of interval- and screen-detected cancers. JNCI J. Nat. Cancer Inst. 92(13), 1081–1087 (2000)
Matrone, G., Savoia, A.S., Caliano, G., Magenes, G.: The delay multiply and sum beamforming algorithm in ultrasound B-mode medical imaging. IEEE Trans. Med. Imag. 34(4), 940–949 (2015)
McAleavey, S.A., Menon, M., Orszulak, J.: Shear-modulus estimation by application of spatially-modulated impulsive acoustic radiation force. Ultrason. Imag. 29(2), 87–104 (2007)
Muir, M., Hrynkow, P., Chase, R., Boyce, D., Mclean, D.: The nature, cause, and extent of occupational musculoskeletal injuries among sonographers: recommendations for treatment and prevention. J. Diagn. Med. Sonography 20(5), 317–325 (2004)
Murphey, S.: Work related musculoskeletal disorders in sonography. J. Diagn. Med. Sonography 33(5), 354–369 (2017)
Napoli, M., Freitas, C., Goswami, S., McAleavey, S., Doyley, M., Howard, T.M.: Hybrid force/velocity control with compliance estimation via strain elastography for robot assisted ultrasound screening. In: 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (2018)
Patlan-Rosales, P.A.: A robotic control framework for quantitative ultrasound elastography. Ph.D. thesis, Université Rennes (2018)
Patlan-Rosales, P.A., Krupa, A.: A general framework for automatic robotic palpation. In: Workshop on Medical Imaging Robotics, IROS 2017 (2017)
Rifai, K., et al.: Clinical feasibility of liver elastography by acoustic radiation force impulse imaging (ARFI). Dig. Liver Dis. 43(6), 491–497 (2011)
Risholm, P., Samset, E., Wells, W.: Bayesian estimation of deformation and elastic parameters in non-rigid registration. In: Fischer, B., Dawant, B.M., Lorenz, C. (eds.) WBIR 2010. LNCS, vol. 6204, pp. 104–115. Springer, Heidelberg (2010). https://doi.org/10.1007/978-3-642-14366-3_10
Risholm, P., Ross, J., Washko, G.R., Wells, W.M.: Probabilistic elastography: estimating lung elasticity. In: Székely, G., Hahn, H.K. (eds.) IPMI 2011. LNCS, vol. 6801, pp. 699–710. Springer, Heidelberg (2011). https://doi.org/10.1007/978-3-642-22092-0_57
Schneider, C., Baghani, A., Rohling, R., Salcudean, S.: Remote ultrasound palpation for robotic interventions using absolute elastography. In: Ayache, N., Delingette, H., Golland, P., Mori, K. (eds.) MICCAI 2012. LNCS, vol. 7510, pp. 42–49. Springer, Heidelberg (2012). https://doi.org/10.1007/978-3-642-33415-3_6
Thrun, S., Burgard, W., Fox, D.: Probabilistic Robotics (Intelligent Robotics and Autonomous Agents). The MIT Press, Cambridge (2005)
Zhi, H., Ou, B., Luo, B.M., Feng, X., Wen, Y.L., Yang, H.Y.: Comparison of ultrasound elastography, mammography, and sonography in the diagnosis of solid breast lesions. J. Ultrasound Med. 26(6), 807–815 (2007)
Acknowledgment
This work was supported by the Office of the Assistant Secretary of Defense for Health Affairs through the Breast Cancer Research Program under Award No. W81XWH-17-1-0021 and W81XWH-17-1-0022.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
1 Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
Copyright information
© 2022 The Author(s), under exclusive license to Springer Nature Switzerland AG
About this paper
Cite this paper
Napoli, M.E., Goswami, S., McAleavey, S.A., Doyley, M.M., Howard, T.M. (2022). Probabilistic Mapping of Tissue Elasticity for Robot-Assisted Medical Ultrasound. In: Asfour, T., Yoshida, E., Park, J., Christensen, H., Khatib, O. (eds) Robotics Research. ISRR 2019. Springer Proceedings in Advanced Robotics, vol 20. Springer, Cham. https://doi.org/10.1007/978-3-030-95459-8_43
Download citation
DOI: https://doi.org/10.1007/978-3-030-95459-8_43
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-95458-1
Online ISBN: 978-3-030-95459-8
eBook Packages: Intelligent Technologies and RoboticsIntelligent Technologies and Robotics (R0)