There is a myriad amount of substandard reinforced concrete (RC) buildings in developing countries that do not comply with the requirements and instructions of the current building design codes. In particular, columns in these substandard buildings demonstrate unsatisfactory and undesired behavior against lateral loads, mainly due to low concrete compressive strength and poor reinforcement detailing. The problem is exacerbated when the axial load ratio (ratio of applied axial load to the axial load capacity) and/or the shear ratio (ratio of shear force corresponding to moment capacity (Ve) to the shear capacity (Vr)) is/are high, leading to brittle failure modes. In this study, three full-scale substandard RC columns subjected to high axial load ratio of 0.75 were tested under constant axial load combined with reversed cyclic lateral displacements. Shear ratio (Ve/Vr) of the substandard columns were 0.75 and 0.82 according to ACI 318-19 (ACI 318 (2019) Building Code Requirements for Structural Concrete. American Concrete Institute, Farmington Hills, MI, USA) and (Turkish Building Earthquake Code (Turkish Building Earthquake Code (TBEC) (2018) Disaster & Emergency Management Authority, Ankara, Turkey), respectively. According to the TBEC (Turkish Building Earthquake Code (TBEC) (2018) Disaster & Emergency Management Authority, Ankara, Turkey), columns had a high Ve/(fctmbd) ratio of 1.12, where, fctm, b, and d are the direct tensile strength of concrete, width of the cross-section, and effective depth of the section. The ratio of transverse reinforcement to minimum required transverse reinforcement according to the ACI 318-19 (ACI 318 (2019) Building Code Requirements for Structural Concrete. American Concrete Institute, Farmington Hills, MI, USA) and TBEC (Turkish Building Earthquake Code (TBEC) (2018) Disaster & Emergency Management Authority, Ankara, Turkey) was 0.19 and 0.77, respectively. Two of the columns were retrofitted with an innovative, cost-effective, and easily-applicable strengthening method, through external jacketing with sprayed glass fiber reinforced mortar (GFRM) of different characteristics. The remaining column was tested as the reference specimen to evaluate the efficiency of the strengthening method. The test results demonstrated the extremely poor performance of the reference substandard column as well as the remarkable lateral load capacity and ductility improvement provided by the adopted novel strengthening approach.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 509.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 649.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 649.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  • ACI 374.2R-13 (2013) Guide for Testing Reinforced Concrete Structural Elements Under Slowly Applied Simulated Seismic Loads. American Concrete Institute, Farmington Hills, MI, USA

    Google Scholar 

  • ACI 318 (2019) Building Code Requirements for Structural Concrete. American Concrete Institute, Farmington Hills, MI, USA

    Google Scholar 

  • ASCE/SEI, 41-17 (2017) Seismic Evaluation and Retrofit of Existing Buildings. American Society of Civil Engineers, Reston, USA

    Google Scholar 

  • ASTM C109/109M-16a (2016) Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens). American Society for Testing and Materials. West Conshohocken, PA, USA

    Google Scholar 

  • ASTM C39/C39M-16b (2016) Standard test method for compressive strength of cylindrical concrete specimens. American Society for Testing and Materials. West Conshohocken, PA, USA

    Google Scholar 

  • Ates AO, Khoshkholghi S, Tore E, Marasli M, Ilki A (2019) Sprayed glass fiber–reinforced mortar with or without basalt textile reinforcement for jacketing of low-strength concrete prisms. J Compos Constr 23(2):04019003

    Article  Google Scholar 

  • Comert M et al (2014) Seismic retrofit of sub-standard RC columns through basalt mesh reinforced sprayed GFRC jacketing. In: Proceedings of the FRC

    Google Scholar 

  • Turkish Building Earthquake Code (TBEC) (2018) Disaster & Emergency Management Authority, Ankara, Turkey

    Google Scholar 

  • D’Ambrisi A, Feo L, Focacci F (2013) Experimental analysis on bond between PBO-FRCM strengthening materials and concrete. Compos B Eng 44(1):524–532

    Article  Google Scholar 

  • Farrokh Ghatte H, Comert M, Demir C, Ilki A (2016) Evaluation of FRP confinement models for substandard rectangular RC columns based on full-scale reversed cyclic lateral loading tests in strong and weak directions. Polymers 8(9):323

    Article  Google Scholar 

  • Farrokh Ghatte H, Comert M, Demir C, Akbaba M, Ilki A (2019) Seismic retrofit of full-scale substandard extended rectangular RC columns through CFRP jacketing: test results and design recommendations. J Compos Constr 23(1):04018071

    Article  Google Scholar 

  • Ilki A, Demir C, Bedirhanoglu I, Kumbasar N (2009) Seismic retrofit of brittle and low strength RC columns using fiber reinforced polymer and cementitious composites. Adv Struct Eng 12(3):325–347

    Article  Google Scholar 

  • Ilki A, Kumbasar N, Koc V (2004) Low strength concrete members externally confined with FRP sheets. Struct Eng Mech 18(2):167–194

    Article  Google Scholar 

  • Li Y, Yin S, Dai J, Liu M (2020) Numerical investigation on the influences of different factors on the seismic performance of TRC-strengthened RC columns. J Building Eng 30:101245

    Google Scholar 

  • Ministry of Public Works and Housing (1975) Afet Bölgelerinde Yapılacak Yapılar Hakkında Yönetmelik. (Regulation for structures in disaster areas.) Official Gazette (1975) (in Turkish)

    Google Scholar 

  • Mirmiran A, Shahawy M, Samaan M, Echary HE, Mastrapa JC, Pico O (1998) Effect of column parameters on FRP-confined concrete. J Compos Constr 2(4):175–185

    Article  Google Scholar 

  • Paulay T, Priestley MN (1992) Seismic design of reinforced concrete and masonry buildings

    Google Scholar 

  • Sezen H, Moehle JP (2004) Shear strength model for lightly reinforced concrete columns. J Struct Eng 130(11):1692–1703

    Article  Google Scholar 

  • Priestley MJN, Calvi GM, Kowalsky MJ (2007) Displacement-based seismic design of structures. IUSS Press, Pavia, Italy

    Google Scholar 

  • Teng J, Huang YL, Lam L, Ye LP (2007) Theoretical model for fiber-reinforced polymer-confined concrete. J Compos Constr 11(2):201–210

    Article  Google Scholar 

  • Triantafillou TC, Papanicolaou CG, Zissimopoulos P, Laourdekis T (2006) Concrete confinement with textile-reinforced mortar jackets. ACI Mater J 103(1):28

    Google Scholar 

  • TS500/2000 (TSE) (2000) Requirements for Design and Construction of Reinforced Concrete Structures, Turkish Standards Institute, Ankara

    Google Scholar 

  • Yoddumrong P, Rodsin K, Katawaethwarag S (2020) Seismic strengthening of low-strength RC concrete columns using low-cost glass fiber reinforced polymers (GFRPs). Case Studies in Construction Materials, 13:e00383

    Google Scholar 

Download references

Acknowledgments

This research was granted in the scope of the bilateral collaboration between the research councils of Turkey (TUBITAK) and the United Kingdom (RCUK) under the grant number 216M379. The authors are most thankful to the Fibrobeton company for their continuous support from the construction phase of the specimens to the testing stage. The contributions of Furkan Narlitepe, Merve Nur Demir, Alihan Baltaci, Muhsin Can Luleci, Bilal Sari, Safiye Gundogan, Erkan Tore and summer trainees are gratefully acknowledged.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Nima Kian .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2022 The Author(s), under exclusive license to Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Kian, N., Demir, U., Demir, C., Marasli, M., Ilki, A. (2022). Seismic Performance of Substandard RC Columns Retrofitted with Sprayed GFRM. In: Ilki, A., Ispir, M., Inci, P. (eds) 10th International Conference on FRP Composites in Civil Engineering. CICE 2021. Lecture Notes in Civil Engineering, vol 198. Springer, Cham. https://doi.org/10.1007/978-3-030-88166-5_114

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-88166-5_114

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-88165-8

  • Online ISBN: 978-3-030-88166-5

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics