Abstract

OSL and TL are luminescent techniques used for individual monitoring for the assessment of doses. Calcium fluoride (CaF2) detectors are successfully applied for personal dosimetry combined TL technique. Studies published in the last years highlight the dosimetric properties of this material with the OSL technique. Considering the advantages of OSL in personal dosimetry and luminescent properties of CaF2 detectors, in this work we developed an algorithm method for evaluation of operational quantity Hp(10) with CaF2 detectors used by workers exposed to radiation energy range find in radiodiagnostic services. A blind test with CaF2 detectors was performed. The analysis of Hp(10) results using the trumpet curve criteria was performed for both setups of energy range of x-ray photon beam. In both blind tests, the criteria of the trumpet curve were fulfilled, demonstrating the applicability of CaF2 detectors with the OSL technique, as the developed algorithm, in radiation monitoring for workers at diagnostic imaging services.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 509.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  1. Yukihara E, Mckeever S. (2011) Optically stimulated luminescence: fundamentals and applications, 1 edn. Wiley, Sl

    Google Scholar 

  2. Haddadchi A, Olley J, Pietsch T (2016) Using LM-OSL of quartz to distinguish sediments derived from surface-soil and channel erosion. Hydrol Process 30:637–647. https://doi.org/10.1002/hyp.10646

    Article  Google Scholar 

  3. Gerke HC, Hinton TG, Takase T, Anderson D, Nanba K, Beasley JC (2020) Radiocesium concentrations and GPS-coupled dosimetry in Fukushima snakes. Sci Total Environ 734. https://doi.org/10.1016/j.scitotenv.2020.139389

  4. Souza SO, Yamamoto T, d’Errico F (2014) Estado da arte em dosimetria do estado sólido. In: International joint conference RADIO 2014. https://inis.iaea.org/collection/NCLCollectionStore/_Public/46/029/46029470.pdf

  5. Malthez ALMC (2015) Desenvolvimento e caracterização de dosímetros para monitoração individual de trabalhadores ocupacionalmente expostos à radiação combinando as técnicas de termoluminescência (TL) e luminescência opticamente estimulada (OSL). PhD Thesis. https://repositorio.unicamp.br/jspui/handle/REPOSIP/261170

  6. Landauer Inc. https://www.landauer.com/

  7. Dosimetrics. https://www.dosimetrics.de/

  8. Malthez ALMC, Marczewska B, Ferreira F, Umisedo NK, Nowak T, Bilski P, Yoshimura E (2018) OSL dosimetric properties and efficiency of brazilian natural calcium fluoride pellets. Appl Radiat Isot 135:166–170. https://doi.org/10.1016/j.apradiso.2018.01.041

    Article  Google Scholar 

  9. Okuno E, Umisedo N, Cancio FS, Aldred M, Yoshimura EM (2017) Three decades of occupational individual monitoring at the University of São Paulo. Radiat Prot Dosim 177:285–288. https://doi.org/10.1093/rpd/ncx042

    Article  Google Scholar 

  10. Umisedo N, Okuno E, Cancio F, Yoshimura EM, Künzel R (2020) Development of a mechanically resistant fluorite-based pellet to be used in personal dosimetry. Radiat Meas 134. https://doi.org/10.1016/j.radmeas.2020.106330

  11. Kearfott KJ, West WJ, Rafique M (2015) The optically stimulated luminescence (OSL) properties of LiF: Mg, TI, Li2B4O7:CU, CaSO4:Tm, and CaF2:MN thermoluminescent (TL) materials. Appl Radiat Isot 99:155–161. https://doi.org/10.1016/j.apradiso.2015.03.004

    Article  Google Scholar 

  12. Lopes CC, Barros VSM, Asfora V, Yamamoto ME, Khoury HJ, Guzzo P Optically stimulated luminescence of CaF2:Ce. J Lumin 199:266–270. https://doi.org/10.1016/j.jlumin.2018.03.059

  13. Malthez ALMC, Yoshimura EM, Button VLSN, Freitas MB (2018) Characterization and performance tests of a new OSL/TL personal dosemeter for individual monitoring. Radiat Prot Dosimetry 182(2):258–265. https://doi.org/10.1093/rpd/ncy058

    Article  Google Scholar 

  14. EC. BS EN IEC 62387-1:2012 (2012) Radiation protection instrumentation. Passive integrating dosimetry systems for environmental and personal monitoring. General characteristics and performance requirements

    Google Scholar 

  15. IAEA (1999) Assessment of occupational exposures due to external sources of radiation—safety standards series No. RS-G-1.3. International Atomic Energy Agency

    Google Scholar 

  16. ISO (1999) ISO 4037–3—X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy—part 3: calibration of area and personal dosemeters. International Organization for Standardization, Geneva

    Google Scholar 

  17. Stadtmann H, Grimbergen TWM, McWhan A, Figel M, Romero AM (2012) EURADOS Intercomparisons for individual monitoring services: Results and conclusions from the first three exercises. https://www.irpa.net/members/TS2f.1.pdf

  18. Malthez ALMC, Martins G, Umisedo N, Yoshimura E (2018) Low-cost flexible OSL detector leaf for 2D radiation measurements. ISPR14, Cordoba

    Google Scholar 

  19. Guimarães CC (2000) Implementação de Grandezas Operacionais na Monitoração Individual e de Área. Master Dissertation. Universidade de São Paulo, São Paulo

    Google Scholar 

  20. Reina TR, Vieira D, Costa P (2013) Determinação e Validação das Qualidades de radiação RQR e RQA da IAEA. In: XVIII Congresso Brasileiro de Física Médica. São Pedro, [s.n.]

    Google Scholar 

  21. Afouxenidis D, Polymeris GS, Tsirliganis NC, Kitis G (2012) Computerised curve deconvolution of TL/OSL curves using a popular spreadsheet program. Radiat Prot Dosimetry 149(4):363–370. https://doi.org/10.1093/rpd/ncr315

    Article  Google Scholar 

  22. Alencar MAV (2013) Processo de Certificação—Serviço de monitoração individual externa. Sociedade Brasileira de Proteção Radilógica, 2013 at: https://www.sbpr.org.br/old/web/IRPA2013/programacaoirpa2013/IRPA2013/GAVEAB/Dia16/0930MarcusVallimGaveaBdia16.pdf

Download references

Acknowledgements

The authors thank the Institute of Physics of Sao Paulo University (IFUSP) for the use of Riso TL/OSL reader and radiation sources.

Conflict of Interest The authors declare that they have no conflict of interest.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2022 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Pagotto, I., Lazzari, R., Filipov, D., Mariano, L., Malthez, A.L.M.C. (2022). Assessment of Dose with CaF2 OSL Detectors for Individual Monitoring in Radiodiagnostic Services Using a Developed Algorithm Based on OSL Decay Curve. In: Bastos-Filho, T.F., de Oliveira Caldeira, E.M., Frizera-Neto, A. (eds) XXVII Brazilian Congress on Biomedical Engineering. CBEB 2020. IFMBE Proceedings, vol 83. Springer, Cham. https://doi.org/10.1007/978-3-030-70601-2_358

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-70601-2_358

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-70600-5

  • Online ISBN: 978-3-030-70601-2

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics