Abstract
OSL and TL are luminescent techniques used for individual monitoring for the assessment of doses. Calcium fluoride (CaF2) detectors are successfully applied for personal dosimetry combined TL technique. Studies published in the last years highlight the dosimetric properties of this material with the OSL technique. Considering the advantages of OSL in personal dosimetry and luminescent properties of CaF2 detectors, in this work we developed an algorithm method for evaluation of operational quantity Hp(10) with CaF2 detectors used by workers exposed to radiation energy range find in radiodiagnostic services. A blind test with CaF2 detectors was performed. The analysis of Hp(10) results using the trumpet curve criteria was performed for both setups of energy range of x-ray photon beam. In both blind tests, the criteria of the trumpet curve were fulfilled, demonstrating the applicability of CaF2 detectors with the OSL technique, as the developed algorithm, in radiation monitoring for workers at diagnostic imaging services.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Yukihara E, Mckeever S. (2011) Optically stimulated luminescence: fundamentals and applications, 1 edn. Wiley, Sl
Haddadchi A, Olley J, Pietsch T (2016) Using LM-OSL of quartz to distinguish sediments derived from surface-soil and channel erosion. Hydrol Process 30:637–647. https://doi.org/10.1002/hyp.10646
Gerke HC, Hinton TG, Takase T, Anderson D, Nanba K, Beasley JC (2020) Radiocesium concentrations and GPS-coupled dosimetry in Fukushima snakes. Sci Total Environ 734. https://doi.org/10.1016/j.scitotenv.2020.139389
Souza SO, Yamamoto T, d’Errico F (2014) Estado da arte em dosimetria do estado sólido. In: International joint conference RADIO 2014. https://inis.iaea.org/collection/NCLCollectionStore/_Public/46/029/46029470.pdf
Malthez ALMC (2015) Desenvolvimento e caracterização de dosímetros para monitoração individual de trabalhadores ocupacionalmente expostos à radiação combinando as técnicas de termoluminescência (TL) e luminescência opticamente estimulada (OSL). PhD Thesis. https://repositorio.unicamp.br/jspui/handle/REPOSIP/261170
Landauer Inc. https://www.landauer.com/
Dosimetrics. https://www.dosimetrics.de/
Malthez ALMC, Marczewska B, Ferreira F, Umisedo NK, Nowak T, Bilski P, Yoshimura E (2018) OSL dosimetric properties and efficiency of brazilian natural calcium fluoride pellets. Appl Radiat Isot 135:166–170. https://doi.org/10.1016/j.apradiso.2018.01.041
Okuno E, Umisedo N, Cancio FS, Aldred M, Yoshimura EM (2017) Three decades of occupational individual monitoring at the University of São Paulo. Radiat Prot Dosim 177:285–288. https://doi.org/10.1093/rpd/ncx042
Umisedo N, Okuno E, Cancio F, Yoshimura EM, Künzel R (2020) Development of a mechanically resistant fluorite-based pellet to be used in personal dosimetry. Radiat Meas 134. https://doi.org/10.1016/j.radmeas.2020.106330
Kearfott KJ, West WJ, Rafique M (2015) The optically stimulated luminescence (OSL) properties of LiF: Mg, TI, Li2B4O7:CU, CaSO4:Tm, and CaF2:MN thermoluminescent (TL) materials. Appl Radiat Isot 99:155–161. https://doi.org/10.1016/j.apradiso.2015.03.004
Lopes CC, Barros VSM, Asfora V, Yamamoto ME, Khoury HJ, Guzzo P Optically stimulated luminescence of CaF2:Ce. J Lumin 199:266–270. https://doi.org/10.1016/j.jlumin.2018.03.059
Malthez ALMC, Yoshimura EM, Button VLSN, Freitas MB (2018) Characterization and performance tests of a new OSL/TL personal dosemeter for individual monitoring. Radiat Prot Dosimetry 182(2):258–265. https://doi.org/10.1093/rpd/ncy058
EC. BS EN IEC 62387-1:2012 (2012) Radiation protection instrumentation. Passive integrating dosimetry systems for environmental and personal monitoring. General characteristics and performance requirements
IAEA (1999) Assessment of occupational exposures due to external sources of radiation—safety standards series No. RS-G-1.3. International Atomic Energy Agency
ISO (1999) ISO 4037–3—X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy—part 3: calibration of area and personal dosemeters. International Organization for Standardization, Geneva
Stadtmann H, Grimbergen TWM, McWhan A, Figel M, Romero AM (2012) EURADOS Intercomparisons for individual monitoring services: Results and conclusions from the first three exercises. https://www.irpa.net/members/TS2f.1.pdf
Malthez ALMC, Martins G, Umisedo N, Yoshimura E (2018) Low-cost flexible OSL detector leaf for 2D radiation measurements. ISPR14, Cordoba
Guimarães CC (2000) Implementação de Grandezas Operacionais na Monitoração Individual e de Área. Master Dissertation. Universidade de São Paulo, São Paulo
Reina TR, Vieira D, Costa P (2013) Determinação e Validação das Qualidades de radiação RQR e RQA da IAEA. In: XVIII Congresso Brasileiro de Física Médica. São Pedro, [s.n.]
Afouxenidis D, Polymeris GS, Tsirliganis NC, Kitis G (2012) Computerised curve deconvolution of TL/OSL curves using a popular spreadsheet program. Radiat Prot Dosimetry 149(4):363–370. https://doi.org/10.1093/rpd/ncr315
Alencar MAV (2013) Processo de Certificação—Serviço de monitoração individual externa. Sociedade Brasileira de Proteção Radilógica, 2013 at: https://www.sbpr.org.br/old/web/IRPA2013/programacaoirpa2013/IRPA2013/GAVEAB/Dia16/0930MarcusVallimGaveaBdia16.pdf
Acknowledgements
The authors thank the Institute of Physics of Sao Paulo University (IFUSP) for the use of Riso TL/OSL reader and radiation sources.
Conflict of Interest The authors declare that they have no conflict of interest.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2022 Springer Nature Switzerland AG
About this paper
Cite this paper
Pagotto, I., Lazzari, R., Filipov, D., Mariano, L., Malthez, A.L.M.C. (2022). Assessment of Dose with CaF2 OSL Detectors for Individual Monitoring in Radiodiagnostic Services Using a Developed Algorithm Based on OSL Decay Curve. In: Bastos-Filho, T.F., de Oliveira Caldeira, E.M., Frizera-Neto, A. (eds) XXVII Brazilian Congress on Biomedical Engineering. CBEB 2020. IFMBE Proceedings, vol 83. Springer, Cham. https://doi.org/10.1007/978-3-030-70601-2_358
Download citation
DOI: https://doi.org/10.1007/978-3-030-70601-2_358
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-70600-5
Online ISBN: 978-3-030-70601-2
eBook Packages: EngineeringEngineering (R0)