Abstract
Beyond foreign body or fracture fragment removal, the use of hip arthroscopy has expanded into a minimally invasive treatment for the osteosynthesis of select femoral head and acetabular fractures. This section focuses on the arthroscopic surgical techniques enabling arthroscopic reduction and internal fixation of the acute and the malunited femoral head fracture as well as the acetabular rim and anterior column fracture.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Atesok K, Doral MN, Whipple T. Arthroscopy-assisted fracture fixation. Knee Surg Sports Traumatol Arthrosc. 2011;19:320–9.
Matsuda DK. Arthroscopic osteosynthesis of femoral head and acetabular fractures. In: Symposium: arthroscopic treatment of fractures. ISAKOS 2013, 14 May, Toronto; 2013.
Matsuda DK. Hip arthroscopy for trauma: innovative techniques for a new frontier. Orthop Today. 2010. http://www.healio.com/orthopedics/arthroscopy/news/print/orthopedics-today/%7B4bfbbb94-26db-42bf-9bca-1754d7515dcf%7D/hip-arthroscopy-for-trauma-innovative-techniques-for-a-new-frontier
Epstein HC, Wiss DA, Cozen L. Posterior fracture dislocation of the hip with fractures of the femoral head. Clin Orthop Relat Res. 1985;201:9–17.
Yamamoto Y, Ide T, Ono T, Hamada Y. Usefulness of arthroscopic surgery in hip trauma cases. Arthroscopy. 2003;19(3):269–73.
Matsuda DK. A rare fracture, an even rarer treatment: the arthroscopic reduction and internal fixation of an isolated femoral head fracture. Arthroscopy. 2009;25(4):408–12.
Matsuda DK, Hamani D. The clamshell fracture and adjunctive acetabuloplasty in the arthroscopic osteosynthesis of femoral head fractures with femoroacetabular impingement. Arthrosc Tech. 2012;1(1):e5–10.
Matsuda DK. Arthroscopic osteosynthesis of a femoral head malunion. Arthrosc Tech. 2013;3(1):e31–4.
Matsuda DK. Fluoroscopic templating technique for precision arthroscopic rim trimming. Arthroscopy. 2009;25(10):1175–82.
Telleria JJ, Safran MR, Harris AH, Gardi JN, Glick JM. Risk of sciatic nerve traction injury during hip arthroscopy – is it the amount or duration? An intraoperative nerve monitoring study. J Bone Joint Surg Am. 2012;94(22):2025–32.
Matsuda DK, Villamor A. The modified midanterior portal for hip arthroscopy. Arthroscopy Tech. 2014. In Press.
Kocher MS, Frank JS, Nasreddine AY, Safran MR, Philippon MJ, Sekiya JK, Kelly BT, Byrd JW, Guanche CA, Martin HD, Clohisy JC, Mohtadi NG, Griffin DR, Sampson TG, Leunig M, Larson CM, Ilizaliturri VM Jr, McCarthy JC, Gambacorta PG. Intra-abdominal fluid extravasation during hip arthroscopy: a survey of the MAHORN group. Arthroscopy. 2012;28(11):1654–60.
Jamali AA, et al. Minimally invasive bone grafting of cysts of the femoral head and acetabulum in femoroacetabular impingement: arthroscopic technique and case presentation. Arthroscopy. 2010;26(2):279–85.
Epstein NJ, Safran MR. Stress fracture of the acetabular rim: arthroscopic reduction and internal fixation. J Bone Joint Surg Am. 2009;91:1480–6.
Larson CM, Stone RM. The rarely encountered rim fracture that contributes to both femoroacetabular impingement and hip stability: a report of 2 cases of arthroscopic partial excision and internal fixation. Arthroscopy. 2011;27(7):1018–22.
Starr AJ, Jones AL, Reinert CM, Borer DS. Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the acetabulum. Injury. 2001;32(Suppl 1):SA45–50.
Hong G, Cong-Feng L, Cheng-Fang H, Chang-Qing Z, Bing-Fang Z. Percutaneous screw fixation of acetabular fractures with 2D fluoroscopy-based computerized navigation. Arch Orthop Trauma Surg. 2010;130:1177–83.
Xian-Quan W, Jin-Fang C, Xue-Cheng C, et al. A quantitative anatomic study of plate-screw fixation of the acetabular anterior column through an anterior approach. Arch Orthop Trauma Surg. 2010;130:257–62.
Yang JH, Chouhan DK, Oh KJ. Percutaneous screw fixation of acetabular fractures: applicability of hip arthroscopy. Arthroscopy. 2010;26(11):1556–61.
Shahulhameed A, Roberts CS, Pomeroy CL, Acland RD, Giannoudis PV. Mapping the columns of the acetabulum – implications for percutaneous fixation. Injury. 2010;41:339–42.
Bartlett CS, DiFelice GS, Buly RL, Quinn TJ, Green DS, Helfet DL. Cardiac arrest as a result of intraabdominal extravasation of fluid during arthroscopic removal of a loose body from the hip joint of a patient with an acetabular fracture. J Orthop Trauma. 1998;12:294–9.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Section Editor information
Rights and permissions
Copyright information
© 2022 Springer Nature Switzerland AG
About this entry
Cite this entry
Matsuda, D.K. (2022). Surgical Technique: Arthroscopic Reduction and Internal Fixation of Femoral Head and Acetabulum Fractures. In: Nho, S.J., Bedi, A., Salata, M.J., Mather III, R.C., Kelly, B.T. (eds) Hip Arthroscopy and Hip Joint Preservation Surgery. Springer, Cham. https://doi.org/10.1007/978-3-030-43240-9_85
Download citation
DOI: https://doi.org/10.1007/978-3-030-43240-9_85
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-43239-3
Online ISBN: 978-3-030-43240-9
eBook Packages: MedicineReference Module Medicine