Abstract
Nowadays, Electromyography (EMG) signals generated by the amputee’s residual limbs are widely used for the control of myoelectric prostheses, usually with the aid of pattern-recognition algorithms. Since myoelectric prostheses are wearable medical devices, the sensors that integrate them should be appropriate for the users’ daily life, meeting the requirements of lightness, flexibility, greater motion identification, and skin adaptability. Therefore, this study aims to design and test an EMG sensor for prosthetic control, focusing on aspects such as adjustability, lightness, precise and constant signal acquisition; and replacing the conventional components of an EMG sensor with textile materials. The proposed sensor was made with Shieldex Technik-tex P130 + B conductive knitted fabric, with 99% pure silver plating. EMG data acquisition was performed twice on three volunteers: one with the textile sensor, and other with a commercial sensor used in prosthetic applications. Overall, the textile and the commercial sensor presented total average Signal-to-Noise Ratio (SNR) values of 10.24 ± 5.45 dB and 11.74 ± 8.64 dB, respectively. The authors consider that the obtained results are promising and leave room for further improvements in future work, such as designing strategies to deal with known sources of noise contamination and to increase the adhesion to the skin. In sum, the results presented in this paper indicate that, with the appropriate improvements, the proposed textile sensor may have the potential of being used for myoelectric prosthetic control, which can be a more ergonomic and accessible alternative to the sensors that are currently used for controlling these devices.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Jamal, M.Z.: Signal acquisition using surface EMG and circuit design considerations for robotic prosthesis. In: Computational Intelligence in Electromyography Analysis - A Perspective on Current Applications and Future Challengers, pp. 427–445 (2012). https://doi.org/10.5772/52556
ten Kate, J., Smit, G., Breedveld, P.: 3D-printed upper limb prostheses: a review. Disabil. Rehabil. Assist. Technol. 12, 300–314 (2017). https://doi.org/10.1080/17483107.2016.1253117
Dhawan, A.S., et al.: Proprioceptive sonomyographic control: a novel method for intuitive and proportional control of multiple degrees-of-freedom for individuals with upper extremity limb loss. Sci. Rep. 9, 1–15 (2019). https://doi.org/10.1038/s41598-019-45459-7
Calado, A., Soares, F., Matos, D.: A review on commercially available anthropomorphic myoelectric prosthetic hands, pattern-recognition-based microcontrollers and sEMG sensors used for prosthetic control. In: IEEE International Conference on Autonomous Robot Systems and Competitions (ICARSC 2019), pp. 1–6 (2019). https://doi.org/10.1109/icarsc.2019.8733629
Calado, A.: Comparison between low-cost and high-end sEMG sensors for the control of a transradial myoelectric prosthesis (2017). https://doi.org/10.13140/RG.2.2.18311.04008
de Jesus Lima, E., Sanca, A., Arabiam, A.: Development of a 3D printed prosthetic myoelectric hand driven by DC actuators. In: XIII Simpósio Brasileiro de Automação Inteligente. Universidade Federal do Rio Grande do Sul, Porto Alegre (2017)
Poparaguai: Myo + Po. https://www.thingiverse.com/thing:2409406?fbclid=IwAR1Z4LENh4qfVhHfjvdL9-3k6und4c6JYU9L5ALTgshrEEy0I8_74eUky2Y. Accessed 18 Oct 2019
Pantelopoulos, A., Bourbakis, N.G.: A survey on wearable sensor-based systems for health monitoring and prognosis. IEEE Trans. Syst. Man Cybern. Part C Appl. Rev. 40, 1–12 (2010). https://doi.org/10.1109/TSMCC.2009.2032660
Stoppa, M., Chiolerio, A.: Wearable electronics and smart textiles: a critical review. Sens. (Switz.) 14, 11957–11992 (2014). https://doi.org/10.3390/s140711957
Zhang, H., Tian, L., Zhang, L., Li, G.: Using textile electrode EMG for prosthetic movement identification in transradial amputees. In: 2013 IEEE International Conference on Body Sensor Networks, BSN 2013 (2013). https://doi.org/10.1109/BSN.2013.6575510
Li, G., Geng, Y., Tao, D., Zhou, P.: Performance of electromyography recorded using textile electrodes in classifying arm movements. In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, pp. 4243–4246. IEEE EMBS, Boston (2011). https://doi.org/10.1109/IEMBS.2011.6091053
Mangezi, A., Rosendo, A., Howard, M., Stopforth, R.: Embroidered archimedean spiral electrodes for contactless prosthetic control. In: IEEE International Conference on Rehabilitation Robotics, pp. 1343–1348 (2017). https://doi.org/10.1109/ICORR.2017.8009435
Lee, S., Kim, M.O., Kang, T., Park, J., Choi, Y.: Knit band sensor for myoelectric control of surface EMG-based prosthetic hand. IEEE Sens. J. 18, 8578–8586 (2018). https://doi.org/10.1109/JSEN.2018.2865623
Biddiss, E., Chau, T.: Upper limb prosthesis use and abandonment: a survey of the last 25 years. Prosthet. Orthot. Int. 31, 236–257 (2007). https://doi.org/10.1080/03093640600994581
Cordella, F., et al.: Literature review on needs of upper limb prosthesis users (2016). https://doi.org/10.3389/fnins.2016.00209
Biomedical Health and Research Program (BIOMED II) of the European Union: SENIAM. http://www.seniam.org/. Accessed 01 June 2018
Paiva, A., Ferreira, F., Catarino, A., Carvalho, M., Carvalho, H.: Design and characterization of a textile extension sensor for sports and health applications. In: IOP Conference Series: Materials Science and Engineering, vol. 459, p. 6 (2018). https://doi.org/10.1088/1757-899X/459/1/012058
Delagi, E.F., Iazzetti, J., Perotto, A.O., Morrison, D.: Anatomical Guide for the Electromyographer: The Limbs and Trunk. Charles C Thomas Publisher Ltd., New York (2011)
Kamen, G., Gabriel, D.A.: Essentials of Electromyography. Human Kinects, Leeds (2009)
Konrad, P.: The ABC of EMG. A Practical Introduction to Kinesiological Electromyography, pp. 1–60. Noraxon Inc., Scottsdale (2005). https://doi.org/10.1016/j.jacc.2008.05.066
Amrutha, N., Arul, V.H.: A review on noises in EMG signal and its removal. Int. J. Sci. Res. Publ. 7, 23 (2017)
Chowdhury, R.H., Reaz, M.B.I., Bin Mohd Ali, M.A., Bakar, A.A.A., Chellappan, K., Chang, T.G.: Surface electromyography signal processing and classification techniques. Sens. (Switz.) 13, 12431–12466 (2013). https://doi.org/10.3390/s130912431
Winter, D.A.: Biomechanics and Motor Control of Human Movement. Wiley, New York (2009)
Acknowledgments
This work is financed by Project “Deus ex Machina”, NORTE-01-0145-FEDER-000026, funded by CCDRN, through Sistema de Apoio à InvestigaçãoCientífica e Tecnológica (Projetos Estruturados I&D&I) of Programa Operacional Regional do Norte, from Portugal 2020 and by Project UID/CTM/00264/2019 of 2C2T – Centro de Ciência e Tecnologia Têxtil, funded by National Founds through FCT/MCTES.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 ICST Institute for Computer Sciences, Social Informatics and Telecommunications Engineering
About this paper
Cite this paper
Arruda, L.M. et al. (2020). Design and Testing of a Textile EMG Sensor for Prosthetic Control. In: Garcia, N., Pires, I., Goleva, R. (eds) IoT Technologies for HealthCare. HealthyIoT 2019. Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering, vol 314. Springer, Cham. https://doi.org/10.1007/978-3-030-42029-1_3
Download citation
DOI: https://doi.org/10.1007/978-3-030-42029-1_3
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-42028-4
Online ISBN: 978-3-030-42029-1
eBook Packages: Computer ScienceComputer Science (R0)