Skip to main content

Cascade Impactor Study of Aerosolization Process During Passive Dry Powder Inhaler Performance Under Unsteady Versus Steady Flow Conditions

  • Conference paper
  • First Online:
Practical Aspects of Chemical Engineering (PAIC 2019)

Abstract

The passive Dry Powder Inhalers (DPIs) rely on the human’s inspiratory airflow and negative pressure drop to create turbulent energy environment inside the inhaler. It induces the forces provided by the flow field to fluidize and disperse the drug aggregates into respirable aerosol, exposed to fluid motions. Hence, aerosolization, transport and deposition phenomena with respect to unsteady flow conditions constitute a subject of biomedical research applying methodology of chemical and process engineering. In vitro pharmacopoeia methods – inertial impaction sizing techniques – have been adopted to assess the aerodynamic performance of powder drug-device platforms. The necessity of investigating time-dependent breathing profiles during operation of DPIs renders conventional testing insufficient. Recently, a method using cascade impactor, mixing inlet and breathing simulator has been developed. The hypothesis of the study was proven to be true: the dynamics of the flow conditions influence the aerodynamic particle size distribution of a drug-passive DPI platform. Research efforts focused on mimicking DPI drug delivery with time-varying flow profile may help to develop better in vitroin vivo correlation (IVIVC) when linking the information gained from compendial testing to clinical efficacy. Further insight of quality parameters in time series is desired to better understand the dynamics of aerosolization process.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  • Azouz, W., Chrystyn, H.: Clarifying the dilemmas about inhalation techniques for dry powder inhalers: integrating science with clinical practice. Prim. Care Respir. J. 21(2), 208–213 (2012)

    Article  Google Scholar 

  • Chrystyn, H., Safioti, G., Keegstra, J.R., et al.: Effect of inhalation profile and throat geometry on predicted lung deposition of budesonide and formoterol (BF) in COPD: an in-vitro comparison of Spiromax with Turbuhaler. Int. J. Pharm. 491(1–2), 268–276 (2015)

    Article  CAS  Google Scholar 

  • Clark, A.R., Borgström, L.: In vitro testing of pharmaceutical aerosols and predicting lung deposition from in vitro measurements. In: Bisgaard, K., O’Callaghan, C., Smaldone, G.C. (eds.) Drug Delivery to the Lung, pp. 105–142. Marcel Dekker, New York (2002)

    Google Scholar 

  • Colthorpe, P., Voshaar, T., Kieckbusch, T., et al.: Delivery characteristics of a low-resistance dry-powder inhaler used to deliver the long-acting muscarinic antagonist glycopyrronium. J. Drug Assess. 2(1), 11–16 (2013)

    Article  Google Scholar 

  • Delvadia, R.R., Wei, X., Longest, P.W., et al.: In Vitro tests for aerosol deposition. IV: simulating variations in human breath profiles for realistic DPI testing. J. Aerosol Med. Pulm. Drug Deliv. 29(2), 196–206 (2016)

    Article  Google Scholar 

  • Dorosz, A., Penconek, A., Moskal, A.: In vitro study on the aerosol emitted from the DPI inhaler under two unsteady inhalation profiles. J. Aerosol Sci. 101, 104–117 (2016)

    Article  CAS  Google Scholar 

  • Marple, V.A., Hochrainer, D., Roberts, D.L., et al.: Next generation pharmaceutical impactor (a new impactor for pharmaceutical inhaler testing). Part I: design. J. Aerosol Med. 16(3), 283–299 (2003)

    Article  Google Scholar 

  • Miller, N.C., Maniaci, M.J., Dwivedi, S.K., et al.: Aerodynamic sizing with simulated inhalation profiles: total dose capture and measurement. In: Dalby, R.N., Byron, P.R., Farr, S.J., et al. (eds.) Proceedings of Respiratory Drug Delivery VII, United States of America, May 2000, vol. 1, pp. 191–196. Virginia Commonwealth University (2000)

    Google Scholar 

  • Mitchell, J.P., Nagel, M.W.: Particle size analysis of aerosols from medicinal inhalers. KONA Powder Part. J. 22, 32–65 (2004)

    Article  Google Scholar 

  • Mitchell, J., Newman, S., Chan, H.K.: In vitro and in vivo aspects of cascade impactor tests and inhaler performance: a review. AAPS PharmSciTech 8(4), 237–248 (2007)

    Article  Google Scholar 

  • Nadarassan, D.K., Assi, K.H., Chrystyn, H.: Aerodynamic characteristics of a dry powder inhaler at low inhalation flows using a mixing inlet with an Andersen Cascade Impactor. Eur. J. Pharm. Sci. 39, 348–354 (2010)

    Article  CAS  Google Scholar 

  • Olsson, B., Borgström, L., Lundbäck, H., Svensson, M.: Validation of a general in vitro approach for prediction of total lung deposition in healthy adults for pharmaceutical inhalation products. J. Aerosol Med. Pulm. Drug Deliv. 26(6), 355–369 (2013)

    Article  CAS  Google Scholar 

  • Sosnowski, T.R.: Powder particles and technologies for medicine delivery to the respiratory system: challenges and opportunities. KONA Powder Part. J. 35, 122–138 (2018)

    Article  CAS  Google Scholar 

  • The United States Pharmacopoeial Convention: United States Pharmacopoeia Thirtieth Revision - <601>Aerosols, nasal sprays, metered-dose inhalers, and dry powder inhalers, Rockville, USA (2007)

    Google Scholar 

  • Ung, K.T., Chan, H.K.: Effects of ramp-up of inspired airflow on in vitro aerosol dose delivery performance for certain dry powder inhalers. Eur. J. Pharm. Sci. 84, 46–54 (2016)

    Article  CAS  Google Scholar 

  • Wei, X., Hindle, M., Delvadia, R.R.: In vitro tests for aerosol deposition. V: using realistic testing to estimate variations in aerosol properties at the trachea. J. Aerosol Med. Pulm. Drug Deliv. 30(5), 339–348 (2017)

    Article  CAS  Google Scholar 

  • Wei, X., Hindle, M., Kaviratna, A., et al.: In vitro tests for aerosol deposition. VI: realistic testing with different mouth-throat models and in vitro - in vivo correlations for a dry powder inhaler, metered dose inhaler, and soft mist inhaler. J. Aerosol Med. Pulm. Drug Deliv. 31(6), 358–371 (2018)

    Article  CAS  Google Scholar 

  • Ziffels, S., Bemelmans, N.L., Durham, P.G., et al.: In vitro dry powder inhaler formulation performance considerations. J. Controlled Release 199, 45–52 (2015)

    Article  CAS  Google Scholar 

Download references

Acknowledgments

This study was supported by the National Science Centre, Poland (project no. 2017/25/N/ST8/00809).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Agata Dorosz .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Dorosz, A., Martínez Cánovas, P., Moskal, A. (2020). Cascade Impactor Study of Aerosolization Process During Passive Dry Powder Inhaler Performance Under Unsteady Versus Steady Flow Conditions. In: Ochowiak, M., Woziwodzki, S., Mitkowski, P., Doligalski, M. (eds) Practical Aspects of Chemical Engineering. PAIC 2019. Springer, Cham. https://doi.org/10.1007/978-3-030-39867-5_6

Download citation

Publish with us

Policies and ethics