Abstract
In this study we present the development of a gamma-ray detector based on 1 mm pixel Gd3Al2Ga3O12:Ce (GAGG:Ce) scintillators and a silicon photomultiplier array (ArraySL-4) for possible applications in medical imaging detectors (with focus in PET applications) as well as in personal gamma radiation monitoring applications (with focus on 137Cs radioisotope recognition). A 12 × 12 matrix of pixellated scintillators is coupled to a 4 × 4 pixel elements of a SIPM array covering an active area of 13.4 mm2. Experimental evaluation was carried out with 22Na and 137Cs radioactive sources and the parameters studied were intrinsic spatial resolution, energy resolution and peak-to-valley ratio. ArraySL-4 is a commercially available, 4 × 4 array detector covering an active area of 13.4 mm2. The GAGG:Ce scintillator array used in this study has 1 × 1 × 10 mm3 pixel size elements with 0.1 mm thickness white BaSO4 reflector material between the crystals. A symmetric resistive charge division matrix was applied reducing array’s 16 outputs to 4 position signals. A Field Programmable Gate Array (FPGA) Spartan 6 LX150T was used for triggering and signal processing of the signal pulses digitized using free running Analog to Digital Converters. Raw images and horizontal profiles of the 12 × 12 GAGG:Ce scintillator array produced under 511 keV and 662 keV excitation are illustrated. Moreover, the energy spectra obtained with 22Na and 137Cs radioactive sources are shown. All GAGG:Ce central pixels were separated in the 2-dimensional position histograms providing submillimeter intrinsic spatial resolution with an average peak-to-valley (P/V) ratio of 1.75 for 511 keV and P/V ratio 1.85 for 662 keV. The energy resolution was 16.9% for 511 keV and 14% for 662 keV. Those encouraging results, prove that this system could build up to a compact miniature 137Cs spectrometer (with 2D isotope mapping capability) for homeland security applications as well as can be used in small animal imaging PET detector systems.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
W. Chaiphaksa, P. Limkitjaroenporn, H.J. Kim, J. Kaewkhao, The mass attenuation coefficients, effective atomic numbers and effective electron densities for GAGG:Ce and CaMoO4 scintillators. Prog. Nucl. Energy 92, 48–53 (2016)
J. Iwanowska, L. Swiderski, T. Szczesniak, P. Sibczynski, M. Moszynski, M. Grodzicka et al., Performance of cerium-doped Gd3Al2G.A3O12 (GAGG:Ce) scintillator. Nucl. Instrum. Methods Phys. Res. A 712, 34–40 (2013)
K. Kamada, T. Yanagida, T. Endo, K. Tsutumi, Y. Usuki, M. Nikl et al., 2 inch diameter single crystal growth and scintillation properties of Ce:Gd3Al2Ga3O12. J. Cryst. Growth 52, 88–90 (2012)
M. Yoneyama, J. Kataoka, M. Arimoto, T. Masuda, M. Yoshino, K. Kamada, A. Yoshikawa, H. Sato, Y. Usuki, Evaluation of GAGG: Ce scintillators for future space applications. JINST 13, P02023 (2018)
M. Lucchini, V. Babin, P. Bohacek, S. Gundacker, K. Kamada, M. Nikl, A. Petrosyan, A. Yoshikawa, E. Auffray, Effect of Mg2+ ions co-doping on timing performance and radiation tolerance of cerium doped Gd3Al2Ga3O12 crystals. Nucl. Instrum. Methods Phys. Res. Sect. A: Accel. Spectrometers Detect. Assoc. Equip. A 816, 176–183 (2016)
M.T. Lucchinia, O. Buganov, E. Auffray, P. Bohacek, M. Korjik, D. Kozlov, S. Nargelas et al., Measurement of non-equilibrium carriers dynamics in Ce-doped YAG, LuAG and GAGG crystals with and without Mg-codoping. J. Lumin. 194, 1–7 (2018)
S. Yamamoto, K. Kuroda, M. Senda, Scintillator selection for MR-compatible gamma detectors. IEEE Trans. Nucl. Sci. 50(5), 1683–1685 (2003)
S. Yamamoto, H. Watabe, Y. Kanai, K. Kato, J. Hatazawa et al., Development of an ultrahigh-resolution Si-PM-based dual-head GAGG coincidence imaging system. Nucl. Instrum. Methods Phys. Res. A. 703, 183–189 (2013)
J.Y. Yeom, S. Yamamoto, S.E. Derenzo, V.C. Spanoudaki, K. Kamada, T. Endo et al., First performance results of Ce:GAGG scintillation crystals with silicon photomultipliers. IEEE Trans. Nucl. Sci. 60(2), 988–992 (2013)
T. Kato, J. Kataoka, T. Nakamori, T. Miura, H. Matsuda, A. Kishimoto et al., A novel gamma-ray detector with submillimeter resolutions using a monolithic MPPC array with pixelized Ce:LYSO and Ce:GGAG crystals. Nucl. Instr. and Meth. Phys. Res. A 699, 235–241 (2013)
S. Yamamoto, J.Y. Yeom, K. Kamada, T. Endo, C.S. Levin, Development of an ultrahigh resolution block detector based on 0.4 mm pixel Ce:GAGG scintillators and a silicon photomultiplier array. IEEE Trans. Nucl. Sci. 60(6), 4582–4587 (2013)
M. Georgiou, S. David, E. Fysikopoulos, G. Loudos, Development of a SIPM based gamma-ray imager using a Gd3Al2Ga3O12:Ce (GAGG:Ce) scintillator array, in IEEE Nuclear Science Symposium and Medical Imaging Conference, pp. M21–M48 (2013)
S. David, M. Georgiou, E. Fysikopoulos, G. Loudos, Evaluation of a SIPM array coupled to a Gd3Al2Ga3O12: Ce (GAGG:Ce) discrete scintillator. Phys. Med. 31, 763–766 (2015)
J.H. Kim, K.H. Park, K.S. Joo, Development of compact and real-time radiation detector based on SiPM for gamma-ray spectroscopy. JINST 13, P07018 (2018)
J.H. Kim, K.H. Park, K.S. Joo, Development of low-cost, compact, real-time, and wireless radiation monitoring system in underwater environment. Nucl. Eng. Technol. 50, 801–805 (2018)
Available online at: http://www.furukawa-denshi.co.jp/cgi-bin/pdfdata/20140428162950.pdf
V. Popov, Matrix output device readout system. U.S. Patent 6,747,263 (2004)
V. Popov, S. Majewski, B. Welch, A novel readout concept for multianode photomultiplier tubes with pad matrix anode layout. Nucl. Instrum. Methods A. 567, 319–322 (2006)
V. Popov, S. Majewski, A.G. Weisenberger, Readout electronics for multianode photomultiplier tubes with pad matrix anode layout. IEEE Nucl. Sci. Conf. R 3, 2156–2159 (2003)
S. David, M. Georgiou, E. Fysikopoulos, G. Loudos, Comparison of three resistor network division circuits for the readout of 4 × 4 pixel SiPM arrays. Nucl. Instrum. Methods Phys. Res. A 702, 121–125 (2013)
12-Bit Octal-Channel ADC Family Up to 65MSPS (Texas Instruments, Dallas, TX, USA, 2008)
E. Fysikopoulos, G. Loudos, M. Georgiou, S. David, G. Matsopoulos, A Spartan 6 FPGA-based data acquisition system for dedicated imagers in nuclear medicine. Meas. Sci. Technol. 23(12), 125403 (2012)
E. Pratiwi, H.T. Leem, J.H. Park, Y. Choi, S. Yamamoto, K. Kamada, A. Yoshikawa, J.Y. Yeom, Performance of a 0.4 mm pixelated Ce:GAGG block detector with digital silicon photomultiplier. IEEE Trans. Radiat. Plasma Med. Sci. 1, 30–35 (2017)
Acknowledgements
This research is implemented through IKY scholarships programme and co-financed by the European Union (European Social Fund—ESF) and Greek national funds through the action entitled” Reinforcement of Postdoctoral Researchers”, in the framework of the Operational Programme” Human Resources Development Program, Education and Lifelong Learning” of the National Strategic Reference Framework (NSRF) 2014–2020.
We would like to thanks Prof. S. Majewski who has provided us the GAGG:Ce matrix as well as Dr. L. Fysikopoulos and Dr. M. Georgiou for their contribution in read out signal processing and front end electronics.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this paper
Cite this paper
David, S., Kandarakis, I. (2019). Development of a Submillimeter Portable Gamma-Ray Imaging Detector, Based on a GAGG:Ce—Silicon Photomultiplier Array. In: Korzhik, M., Gektin, A. (eds) Engineering of Scintillation Materials and Radiation Technologies. ISMART 2018. Springer Proceedings in Physics, vol 227. Springer, Cham. https://doi.org/10.1007/978-3-030-21970-3_15
Download citation
DOI: https://doi.org/10.1007/978-3-030-21970-3_15
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-21969-7
Online ISBN: 978-3-030-21970-3
eBook Packages: Physics and AstronomyPhysics and Astronomy (R0)