Abstract

The field of cardiac electrophysiology has evolved dramatically in the last decades. Catheter ablation is now the standard of care for the treatment of several arrhythmias and the development of technology allows for more and more complex procedures to be realized.

3D mapping is used during many EP procedures for anatomic reconstruction, navigation, activation mapping (integration of the timing of recorded electrograms), and voltage mapping (integration of the amplitude of local signal). Systems used today have evolved to allow precision in localization of catheters and anatomical landmark, reliability and stability of the virtual anatomy, integration of different imaging modalities, and multiple features to facilitate mapping and ablation. This chapter mainly focuses on the reduction in fluoroscopy that can be achieved using 3D mapping systems.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 89.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 119.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Khaykin Y, Oosthuizen R, Zarnett L, Wulffhart ZA, Whaley B, Hill C, et al. CARTO-guided vs. NavX-guided pulmonary vein antrum isolation and pulmonary vein antrum isolation performed without 3-D mapping: effect of the 3-D mapping system on procedure duration and fluoroscopy time. J Interv Card Electrophysiol. 2011;30(3):233–40.

    Article  Google Scholar 

  2. Christoph M, Wunderlich C, Moebius S, Forkmann M, Sitzy J, Salmas J, et al. Fluoroscopy integrated 3D mapping significantly reduces radiation exposure during ablation for a wide spectrum of cardiac arrhythmias. Europace. 2015;17(6):928–37.

    Article  Google Scholar 

  3. Estner HL, Deisenhofer I, Luik A, Ndrepepa G, von Bary C, Zrenner B, et al. Electrical isolation of pulmonary veins in patients with atrial fibrillation: reduction of fluoroscopy exposure and procedure duration by the use of a non-fluoroscopic navigation system (NavX). Europace. 2006;8(8):583–7.

    Article  Google Scholar 

  4. Yang L, Sun G, Chen X, Chen G, Yang S, Guo P, et al. Meta-analysis of zero or near-zero fluoroscopy use during ablation of cardiac arrhythmias. Am J Cardiol. 2016;118(10):1511–8.

    Article  Google Scholar 

  5. Calkins H, Hindricks G, Cappato R, Kim YH, Saad EB, Aguinaga L, et al. 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm. 2017;14(10):e275–444.

    Article  Google Scholar 

  6. Prolic Kalinsek T, Jan M, Rupar K, Razen L, Antolic B, Zizek D. Zero-fluoroscopy catheter ablation of concealed left accessory pathway in a pregnant woman. Europace. 2017;19(8):1384.

    Article  Google Scholar 

  7. Karbarz D, Stec PJ, Deutsch K, Sledz J, Stec S. Zero-fluoroscopy catheter ablation of symptomatic pre-excitation from non-coronary cusp during pregnancy. Kardiol Pol. 2017;75(12):1351.

    Article  Google Scholar 

  8. Huang X, Chen Y, Huang Z, He L, Liu S, Deng X, et al. Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography. Medicine (Baltimore). 2018;97(25):e11044.

    Article  Google Scholar 

  9. Giaccardi M, Mascia G, Paoletti Perini A, Giomi A, Cartei S, Milli M. Long-term outcomes after “Zero X-ray” arrhythmia ablation. J Interv Card Electrophysiol. 2019;54:43–8.

    Article  Google Scholar 

  10. Sommer P, Bertagnolli L, Kircher S, Arya A, Bollmann A, Richter S, et al. Safety profile of near-zero fluoroscopy atrial fibrillation ablation with non-fluoroscopic catheter visualization: experience from 1000 consecutive procedures. Europace. 2018;20:1952–8.

    Article  Google Scholar 

  11. Alvarez M, Bertomeu-Gonzalez V, Arcocha MF, Morina P, Tercedor L, Ferrero de Loma A, et al. Nonfluoroscopic catheter ablation. Results from a prospective multicenter registry. Rev Esp Cardiol (Engl Ed). 2017;70(9):699–705.

    Article  Google Scholar 

  12. Cappato R, Calkins H, Chen SA, Davies W, Iesaka Y, Kalman J, et al. Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circ Arrhythm Electrophysiol. 2010;3(1):32–8.

    Article  Google Scholar 

  13. Hsia HH, Lin D, Sauer WH, Callans DJ, Marchlinski FE. Anatomic characterization of endocardial substrate for hemodynamically stable reentrant ventricular tachycardia: identification of endocardial conducting channels. Heart Rhythm. 2006;3(5):503–12.

    Article  Google Scholar 

  14. D’Amario D, Leone AM, Narducci ML, Smaldone C, Lecis D, Inzani F, et al. Human cardiac progenitor cells with regenerative potential can be isolated and characterized from 3D-electro-anatomic guided endomyocardial biopsies. Int J Cardiol. 2017;241:330–43.

    Article  Google Scholar 

  15. Corrado D, Basso C, Leoni L, Tokajuk B, Bauce B, Frigo G, et al. Three-dimensional electroanatomic voltage mapping increases accuracy of diagnosing arrhythmogenic right ventricular cardiomyopathy/dysplasia. Circulation. 2005;111(23):3042–50.

    Article  Google Scholar 

  16. Linton NW, Koa-Wing M, Francis DP, Kojodjojo P, Lim PB, Salukhe TV, et al. Cardiac ripple mapping: a novel three-dimensional visualization method for use with electroanatomic mapping of cardiac arrhythmias. Heart Rhythm. 2009;6(12):1754–62.

    Article  Google Scholar 

  17. Luther V, Cortez-Dias N, Carpinteiro L, de Sousa J, Balasubramaniam R, Agarwal S, et al. Ripple mapping: Initial multicenter experience of an intuitive approach to overcoming the limitations of 3D activation mapping. J Cardiovasc Electrophysiol. 2017;28(11):1285–94.

    Article  Google Scholar 

  18. Luther V, Linton NW, Koa-Wing M, Lim PB, Jamil-Copley S, Qureshi N, et al. A prospective study of ripple mapping in atrial tachycardias: a novel approach to interpreting activation in low-voltage areas. Circ Arrhythm Electrophysiol. 2016;9(1):e003582.

    Article  Google Scholar 

  19. Enriquez A, Saenz LC, Rosso R, Silvestry FE, Callans D, Marchlinski FE, et al. Use of intracardiac echocardiography in interventional cardiology: working with the anatomy rather than fighting it. Circulation. 2018;137(21):2278–94.

    Article  Google Scholar 

  20. Khaykin Y, Skanes A, Wulffhart ZA, Gula L, Whaley B, Oosthuizen R, et al. Intracardiac ECHO integration with three dimensional mapping: role in AF ablation. J Atr Fibrillation. 2008;1(2):32.

    PubMed  PubMed Central  Google Scholar 

  21. Moak JP, Sumihara K, Swink J, Hanumanthaiah S, Berul CI. Ablation of the vanishing PVC, facilitated by quantitative morphology-matching software. Pacing Clin Electrophysiol. 2017;40(11):1227–33.

    Article  Google Scholar 

  22. Wu J, Estner H, Luik A, Ucer E, Reents T, Pflaumer A, et al. Automatic 3D mapping of complex fractionated atrial electrograms (CFAE) in patients with paroxysmal and persistent atrial fibrillation. J Cardiovasc Electrophysiol. 2008;19(9):897–903.

    Article  Google Scholar 

  23. Jadidi AS, Arentz T. A decade of CFAE mapping: still seeking more specific tools to identify sources and substrate of persistent atrial fibrillation. Arrhythm Electrophysiol Rev. 2015;4(2):108.

    Article  Google Scholar 

  24. Lehrmann H, Jadidi AS, Minners J, Keyl C, Hochholzer W, Carrapatoso F, et al. Important reduction of the radiation dose for pulmonary vein isolation using a multimodal approach. Europace. 2018;20(2):279–87.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Isabelle Nault .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Nault, I. (2019). 3D Mapping and Reduction in Radiation Exposure. In: Proietti, R., Wang, Y., Yao, Y., Zhong, G., Lin Wu, S., Ayala-Paredes, F. (eds) Cardiac Electrophysiology Without Fluoroscopy. Springer, Cham. https://doi.org/10.1007/978-3-030-16992-3_4

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-16992-3_4

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-16991-6

  • Online ISBN: 978-3-030-16992-3

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics