Abstract
Quantitation of specific proteins in complex mixtures is simplified by the use of antibodies directed against the protein of interest. If the specific protein is differentially expressed within a population of cells, quantitation of the protein in cell lysates by immunoblotting will provide an average quantity of the protein per cell. As a result, when lysates of different cell populations are compared, large changes in the amount of a protein in a small percentage of cells cannot be distinguished from small changes in the amount of a protein in a large percentage of cells. Flow cytometric analysis solves this problem by providing a means to measure the amount of a specific protein within each individual cell in a population. A fluorescently labeled probe, usually an antibody, is required for detection of the protein. A single cell suspension is reacted with an antibody and passed through a flow cytometer, which focuses the cell suspension into a stream that intersects a laser beam. As each cell passes through the beam, the fluorescent probe in each cell is excited and photomultiplier tubes register the degree of fluorescence (1).
Multivariate analysis, the simultaneous measurement of multiple parameters, is a powerful feature of flow cytometry. When determining the quantity of a specific protein in a cell, the quantity of other molecules in the same cell can also be measured by using additional fluors specifically targeted to other molecules. Examples of second molecules measured simultaneously include DNA (2–4) or additional proteins (5). In addition, measurement of light scatter can provide information about cell size and granularity. Most flow cytometers are capable of measuring six colors plus light scatter, but specialized flow cytometers that are capable of measuring as many as eighteen colors are now available.
References
Shapiro, H. M. (2003) Practical Flow Cytometry, 4th Ed. Wiley-Liss, New York
Jacobberger, J. W., Fogleman, D., and Lehman, J. M. (1986) Analysis of intracellular antigens by flow cytometry. Cytometry 7, 356–364
Laffin, J. and Lehman, J. M. (1994) Detection of intracellular virus and virus products. Meth. Cell Biol. 41, 543–557.
Lehman J.M., Friedrich T.D. and Laffin J. (2001). Analysis of viral infection and viral and cellular DNA and proteins by flow cytometry. Curr Protocols Cytometry. 7.17.1–7.17.9.
Stewart, C. C. and Stewart, S. J. (1994) Multiparameter analysis of leukocytes by flow cytometry. Meth. Cell Biol. 41, 61–79.
Sramkoski, R.M., Wormsley, S.W., Bolton, W.E., Crumpler, D.E. and Jacobberger, J.W. (1999) Simultaneous Detection of Cyclin B1, p105, and DNA Content Provides Complete Cell Cycle Phase Fraction Analysis of Cells That Endoreduplicate. Cytom-etry 35, 274–283.
Lehman, J. M., Laffin, J., and Friedrich, T. D. (2000) Simian virus 40 induces multiple S phases with the majority of viral DNA replication in the G2 and second S phase in CV-1 cells. Exp. Cell Res. 258, 215–222.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2009 Springer Science+Business Media, LLC
About this protocol
Cite this protocol
Friedrich, T.D., Ray, F.A., Smith, R.L., Lehman, J.M. (2009). Quantitation of Cellular Proteins by Flow Cytometry. In: Walker, J.M. (eds) The Protein Protocols Handbook. Springer Protocols Handbooks. Humana Press, Totowa, NJ. https://doi.org/10.1007/978-1-59745-198-7_9
Download citation
DOI: https://doi.org/10.1007/978-1-59745-198-7_9
Publisher Name: Humana Press, Totowa, NJ
Print ISBN: 978-1-60327-474-6
Online ISBN: 978-1-59745-198-7
eBook Packages: Springer Protocols