Skip to main content

Model-Based Flaw Reconstruction and Flaw Parameter Estimation Using a Limited Set of Radiographic Projections

  • Chapter
Review of Progress in Quantitative Nondestructive Evaluation

Abstract

This paper presents an approach to the reconstruction and parameter estimation of flaw models in NDE radiography. The reconstruction of flaw models rather than the flaw distribution itself reduces the required number of projections as well as the complexity of the measurement system [1,2]. In this approach, crack-like flaws are modeled as piecewise linear curves, and volumetric flaws are modeled as ellipsoids. Our emphasis here is on a method for estimating the model parameters for crack-like flaws using a linear model with more than the minimal number of required projections. Extra projections reduce the effects of measurement errors and film noise. We also present the development of the volumetric flaw model and outline a method for its inversion.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 74.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Wallingford, R. M. and Basart, J. P. in Review of Progress in Quantitative NDE. edited by D. O. Thompson and D. E. Chimenti, ( Plenum Press, New York, 1989 ), Vol 8a, pp. 351–358.

    Google Scholar 

  2. Wallingford, R. M. and Basart, J. P., Twenty-Second Annual Asilomar Conference on Signals, Systems, and Computers.(IEEE Computer Society, Maple Press, 1989 ) pp. 68–72.

    Google Scholar 

  3. Golub, G. H. and Van Loan, C. F., SIAM J. Numer. Anal. Vol. 17, No. 6, pp. 883–893, December, 1980.

    MATH  Google Scholar 

  4. Branham, R. L., Computers in Physics. pp. 42–46, May/June, 1989.

    Google Scholar 

  5. Press, W. H., Flannery, B. P., Teukolsky, S. A. and Vetterling, W. T. Numerical Recipes in C: The Art of Scientific Computing. Sections 14.2, 14.4, 14. 5. ( Cambridge University Press, Cambridge, 1988 ).

    Google Scholar 

  6. Gray, J. N., Inanc, F. and Shull, B. E. in Review of Progress in Quantitative NDE, edited by D. O. Thompson and D. E. Chimenti, ( Plenum Press, New York, 1989 ), Vol. 8a, pp. 345–350.

    Google Scholar 

  7. Fuller, W. A. Measurement Error Models, Sections 3.2, 3. 3 ( Wiley, New York, 1987 ).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1990 Springer Science+Business Media New York

About this chapter

Cite this chapter

Wallingford, R.M., Basart, J.P. (1990). Model-Based Flaw Reconstruction and Flaw Parameter Estimation Using a Limited Set of Radiographic Projections. In: Thompson, D.O., Chimenti, D.E. (eds) Review of Progress in Quantitative Nondestructive Evaluation. Review of Progress in Quantitative Nondestructive Evaluation. Springer, Boston, MA. https://doi.org/10.1007/978-1-4684-5772-8_93

Download citation

  • DOI: https://doi.org/10.1007/978-1-4684-5772-8_93

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4684-5774-2

  • Online ISBN: 978-1-4684-5772-8

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics