Abstract
As a prelude to establishing, (1) criteria for selection of Boron Neutron Capture Therapy (BNCT) epithermal beam clinical trial patients and (2) treatment planning strategies, posttreatment evaluations of dose distributions in several BNCT patients are being done using the Idaho National Engineering Laboratory (INEL) BNCT Program’s patient treatment planning software (bnct_edit and rtt_MC)1,2
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
D. Wessol, J. Cobb, F. Wheeler, E. Cohen, B. Cobb, and D. Barber, Interactive Generation of 3-D B-Spline Objects from Planar Image Data for Multidimensional Analysis, presented at Society of Exploration Geophysicists 60th Ann. Int. Mtg. and Exposition,San Francisco, CÁ, (1990).
F.J. Wheeler and D.W. Nigg, Three-Dimensional Radiation Dose Distribution Analysis for Boron Neutron Capture Therapy, Nucl.Sci.Eng. 110:16(1992).
D.W. Nigg, G.J. Storr, and F.J. Wheeler, Physics Parameters for an Epithermal- Neutron Facility at the Georgia Institute of Technology Research Reactor, These proceedings.
N. Blagojevic, G. Storr, B. Allen, H. Hatanaka, and H. Nakagawa, Role of Heavy Water in Boron Neutron Capture Therapy, presented at International Workshop on Macro and Microdosimetry and treatment planning for Neutron Capture Therapy, Cambridge, MA, (1991).
G.S. Robinson, “A Guide to the AUS Modular Neutronics Code System,” AAEC/E645 (1987)
W.A. Rhoades and R.L. Childs, DORT - Two-Dimensional Discrete Ordinates Transport Code, Oak Ridge National Laboratory, CCC-484,(1989).
D. Haritz, Results of Continued Clinical Investigations of BSH in Patients with Malignant Glioma, These proceedings.
W. Sweet, Massachusetts General Hospital, [private communication].
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1993 Springer Science+Business Media New York
About this chapter
Cite this chapter
Storr, G.J., Wheeler, F.J. (1993). Post Treatment Dose Distribution Evaluation for a Recent NCT Patient. In: Soloway, A.H., Barth, R.F., Carpenter, D.E. (eds) Advances in Neutron Capture Therapy. Springer, Boston, MA. https://doi.org/10.1007/978-1-4615-2978-1_31
Download citation
DOI: https://doi.org/10.1007/978-1-4615-2978-1_31
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4613-6296-8
Online ISBN: 978-1-4615-2978-1
eBook Packages: Springer Book Archive