Abstract
Remote device (CIED) monitoring has become a mainstay of clinical practice involving implanted devices such as pacemakers, defibrillators, and implantable loop recorders. The aims of remote monitoring are to provide accurate, timely, and economical information about both device functions and disease status. Remote monitoring is an integral component of comprehensive CIED management and, as an extension, serves as an additional important tool in device performance surveillance.
While this chapter is unrevised from the 1st edition, and some of the statistics are out of date and some of the company systems have changed, the concepts and directions remain intact.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Schoenfeld MH, Reynolds DW. Sophisticated remote implantable cardioverter-defibrillator follow-up: a status report. Pacing Clin Electrophysiol. 2005;28(3):235–40.
Carlson MD. Recommendations from the Heart Rhythm Society Task Force on Device Performance and Guidelines. Heart Rhythm. 2006;3(10):1250–73.
ACC/AHA Guidelines for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices. A report of the American College of Cardiology/American Heart Association Task Force on Practice (Committee on Pacemaker Implantation). J Am Coll Card. 1998;31(5):1175–209.
Adamson PB, Magalski A, Braunschweig F, et al. Ongoing right ventricular hemodynamics in heart failure: clinical value of measurements derived from an implantable hemodynamic monitor. J Am Coll Cardiol. 2003;41(4):565–71.
Shah NB, Der E, Ruggerio C, et al. Prevention of hospitalizations for heart failure with an interactive home monitoring program. Am Heart J. 1998;135(3):373–8.
Goldberg LR, Piette JD, Walsh MN, et al. Randomized trial of a daily electronic home monitoring system in patients with advanced heart failure: the Weight Monitoring in Heart Failure (WHARF) trial. Am Heart J. 2003;146(4):705–12.
Stewart S, Vandenbroeck AJ, Pearson S, et al. Prolonged beneficial effects of a home-based intervention on unplanned readmissions and mortality among patients with congestive heart failure. Arch Intern Med. 1999;159(3):257–61.
Galbreath AD, Krasuski RA, Smith B, et al. Long-term healthcare and cost outcomes of disease management in a large, randomized, community-based population with heart failure. Circulation. 2004;110:3518–26.
Cleland JG, Louis AA, Rigby AS, Janssens U, et al. Noninvasive home telemonitoring for patients with heart failure at high risk of recurrent admission and death: the Trans-European Network-Home-Care Management System (TEN-HMS) study. J Am Coll Cardiol. 2005;45(10):1654–64.
Falk D, Straub K. Practice efficiency improvements resulting from the use of Medtronic CareLink Network remote monitoring system. Fairfield: Human Factors International; 2004.
Furman S, Escher DJ. Transtelephone pacemaker monitoring. In: Schaldach M, Furman S, editors. Advances in pacemaker technology. Berlin: Springer; 1975. p. 177–94.
Ellenbogen KA, Kay GN, Wilkoff BL. Clinical cardiac pacing. Philadelphia: W.B. Saunders; 1995. p. 796–8.
Furman S, Hayes DL, Holmes DR. A practice of cardiac pacing. 3rd ed. Mount Kisco: Futura; 1993. p. 580–2.
Lyons C, Schroeder P, Shankar K, et al. Transtelephonic monitoring of a tachycardia-terminating pacemaker. Pacing Clin Electrophysiol. 1984;7(1):34–6.
Bhandari AK, Anderson JL, Gilbert EM, et al. Correlation of symptoms with occurrence of paroxysmal supraventricular tachycardia or atrial fibrillation: a transtelephonic monitoring study. Am Heart J. 1992;124(2):381–6.
Fetter JG, Stanton MS, Benditt DG, et al. Transtelephonic monitoring and transmission of stored arrhythmia detection and therapy data from an implantable cardioverter defibrillator. Pacing Clin Electrophysiol. 1995;18(8):1531–9.
Scholten MF, Thorton AS, Theuns DA, Res J, Jordaens LJ. Twiddlers syndrome detected by home monitoring device. Pacing Clin Electrophysiol. 2004;5 Suppl 1:30S–1.
Schoenfeld MH, Comptom SJ, Mead RH, et al. Remote monitoring of implantable cardioverter defibrillators: a prospective analysis. Pacing Clin Electrophysiol. 2004;27(Pt 1):757–63.
Yu CM, Wang L, Chau E, et al. Intrathoracic impedance monitoring in patients with heart failure. Circulation. 2005;112:841–8.
Steinhaus D, Reynolds DW, Gadler F, et al. Implant experience with an implantable hemodynamic monitor for the management of symptomatic heart failure. Pacing Clin Electrophysiol. 2005;28:747–53.
Magalski A, Adamson P, Gadler F, et al. Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: a multicenter, 12-month follow-up study of patients with chronic heart failure. J Card Fail. 2002;8(2):63–70.
Kjellstrom B, Igel D, Abraham J, et al. Trans-telephonic monitoring of continuous haemodynamic measurements in heart failure patients. J Telemed Telecare. 2005;11(5):240–4.
Joseph GK, Wilkoff BL, Dresing T, et al. Remote interrogation and monitoring of implantable cardioverter defibrillators. J Interv Card Electrophysiol. 2004;11:161–6.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag London
About this chapter
Cite this chapter
Reynolds, D.W., Murray, C.M., Germany, R. (2013). Device Therapy for Remote Patient Management. In: Gussak, I., Antzelevitch, C. (eds) Electrical Diseases of the Heart. Springer, London. https://doi.org/10.1007/978-1-4471-4978-1_16
Download citation
DOI: https://doi.org/10.1007/978-1-4471-4978-1_16
Published:
Publisher Name: Springer, London
Print ISBN: 978-1-4471-4977-4
Online ISBN: 978-1-4471-4978-1
eBook Packages: MedicineMedicine (R0)