Abstract
An innovative multiple screening protocol allowing the detection of specific DNA sequences of p35S and epsps in GM soya flours simultaneously was developed. For the application of the Luminex xMAP technology, two different sets of fluorescent beads were cross-linked to the specific oligonucleotide probes previously amplified and labeled by polymerase chain reaction (PCR) in the presence of a biotinylated nucleotide. The detection of the amplification products bounded by the streptavidin–phycoeritrin conjugate was performed using the Luminex-100 instrument. The system allows identification of extremely low amounts of labeled targets as of 7.8 10−4 nmol of p35S antiprobe with an associated value of repeatability relative standard deviation (RSDr) equal to 2.8. Parameters such as repeatability, reproducibility, limit of detection (LOD), and limit of quantification (LOQ) were considered to evaluate the performances of the assay. The potentiality of the system described in this paper enables us to look forward to a multiple target assay that is able to simultaneously detect and eventually quantify tens of target sequences occurring within the same sample preparation. The present study describes the first application of a multitarget fluorescent microsphere-based assay for DNA genetically modified organism (GMO) detection.
Similar content being viewed by others
References
Applied Biosystems. Relative quantification of gene expression. UserBulletin #2 (2001). Applied Biosystem
Aston CE, Ralph DA, Lalo DP, Manjeshwar S, Gramling BA, DeFreese DC, West AD, Branam DE, Thompson LF, Craft MA, Mitchell DS, Shimasaki CD, Mulvihill JJ, Jupe ER (2005) Oligogenic combinations associated with breast cancer risk in women under 53 years of age. Hum Genet 116(3):208–221
Bordoni R, Germini A, Mezzelani A, Marchelli R, De Bellis G (2005) A microarray platform for parallel detection of five transgenic events in foods: a combined polymerase chain reaction-ligation detection reaction-universal array method. J Agric Food Chem 53(4):912–918
Brodmann PD, Ilg EC, Berthoud H, Herrmann A (2002) Real-time quantitative polymerase chain reaction methods for four genetically modified maize varieties and maize DNA content in food. J AOAC Int 85:646–653
Bubner B, Gase G, Baldwin IT (2004) Two-fold differences are the detection limit for determining transgene copy numbers in plants by real-time PCR. BMC Biotechnol 4:14 DOI 10.1186/1472-6750-4-14
Burns MJ, Valdivia H, Harris N (2004) Analysis and interpretation of data from real-time PCR trace detection methods using quantification of GM soya as a model system. Anal Bioanal Chem 387:1616–1623
Burns MJ, Nixon GJ, Foy CA, Harris N (2005) Standardization of data from real-time quantitative PCR methods-evaluation of outliers and comparison of calibration curves. BMC Biotechnol 5:31 DOI 10.1186/1472-6750-5-31
Carson RT, Vignali DA (1999) Simultaneous quantification of 15 cytokines using a multiplex flow cytometer assay. J Immunol Methods 227:41–52
Deshpande A, Nolan JP, White PS, Valdez YE, Hunt WC, Peyton CL, Wheeler CM (2005) TNF-alpha promoter polymorphisms and susceptibility to human papillomavirus 16-associated cervical cancer. J Infect Dis 191(6):969–976
Dunbar SA (2005) Applications of Luminex(R) xMAPtrade mark technology for rapid, high-throughput multiplexed nucleic acid detection. Clin Chim Acta 363(1–2):71–82
Dunbar SA, Jacobson JW (2005) Rapid screening for 31 mutations and polymorphisms in the cystic fibrosis transmembrane conductance regulator gene by Luminex xMAP suspension array. Methods Mol Med 114:147–171
Ermolli M, Prospero A, Balla B, Querci M, Mazzeo A, Van den Eede G (2006) Development of an innovative immunoassay for CP4EPSPS and Cry1Ab GM proteins detection and quantification. Food Addit Contam 23:876–882
European Commission (2004) Recommendation (EC) No 787/2004 of 4 October 2004 on technical guidance for sampling and detection of genetically modified organisms and material produced from genetically modified organisms as or in products in the context of Regulation (EC) No 1830/2003 (Text with EEA relevance) Official Journal of European Union L348:0018–0026
European Commission (2003) Regulation (EC) No 1829/2003 of the European Parliament and of the Council of 22 September 2003 on genetically modified food and feed. Official Journal of European Union L268:0001–0023
European Commission (2003) Regulation (EC) 1830/2003 of the European Parliament and of the Council of 22 September 2003 concerning the traceability and labeling of genetically modified organisms and the traceability of food and feed products produced from genetically modified organisms and amending Directive 2001/18/EC.Official Journal of European Union L268:0024–0028
Feriotto G, Gardenghi S, Bianchi N, Gambari R (2003) Quantitation of bt-176 maize genomic sequences by surface plasmon resonance-based biospecific interaction analysis of multiplex polymerase chain reaction (PCR). J Agric Food Chem 51(16):4640–4646
Flagella M, Bui S, Zheng Z, Nguyen CT, Zhang A, Pastor L, Ma Y, Yang W, Crawford KL, McMaster GK, Witney F, Luo Y (2006) A multiplex branched DNA assay for parallel quantitative gene expression profiling. Anal Biochem 352(1):50–60
García-Cañas V, González R, Cifuentes A (2002) Ultrasensitive detection of genetically modified maize dna by capillary gel electrophoresis with laser-induced fluorescence using different fluorescent intercalating dyes. J Agric Food Chem 50(16):4497–4502
Germini A, Zanetti A, Salati C, Rossi S, Forré C, Schmid S, Marchelli R (2004) Development of a seven-target multiplex pcr for the simultaneous detection of transgenic soybean and maize in feeds and foods. J Agric Food Chem 52(11):3275–3280
Hancock DK, Tully LA, Levin BC (2005) A standard reference material to determine the sensitivity of techniques for detecting low-frequency mutations, SNPs, and heteroplasmies in mitochondrial DNA. Genomics 86(4):446–461
Higuchi R, Fockler C, Dollinger G, Watson R (1993) Kinetic PCR analysis: real-time monitoring of DNA amplification reactions. Bio/Technology 11:1026–1030
Hohne M, Santisi CR, Meyer R (2002) Real-time multiplex PCR: an accurate method for the detection and quantification of 35S CaMV promoter in genetically modified maize containing food. European Food Research and Technology 215(1):59–64
Holst-Jensen A, Ronning SB, Lovseth A, Berdal KG (2003) PCR technology for screening and quantification of genetically modified organisms (GMOs). Anal Bioanal Chem 375:985–993
Holst-Jensen A, De Loose M, Vanden Eede G (2006) Coherence between legal requirements and approaches for detection of genetically modified organisms (GMOs) and their derived products. J Agric Food Chem 54(8):2799–2809 Apr 19
Hubner P, Studer E, Lüthy J (1999) Quantitative competitive PCR for the detection of genetically modified organisms in food. Food Control 10:353–358
Hubner P, Waiblinger HU, Pietsch K, Brodmann P (2001) Validation of PCR methods for quantification of genetically modified plants in food. J AOAC Int 84:1855–1864
Hurley JD, Engle LJ, Davis JT, Welsh AM, Landers JE (2005) A simple, bead-based approach for multi-SNP molecular haplotyping. Nucleic Acids Res 32:e186
Kay S, Van den Eede G (2001) The limits of GMO detection. Nat Biotechnol 19(No5):405
Kubista M, Andrade JM, Bengtsson M, Forootan A, Jonák J, Lind K, Sindelka R, Sjöback R, Sjögreen B, Strömbom L, Ståhlberg A, Zoric N (2006) The real-time polymerase chain reaction. Mol Aspects Med 27:95–125
Li ZP, Kambara H (2005) Single nucleotide polymorphism analysis based on minisequencing coupled with a fluorescence microsphere technology. Journal of Nanoscience and Nanotechnology 58:1256–1260
Lipp M, Shillito R, Giroux R, Spiegelhalter F, Charlton S, Pinero D, Song P (20050 Polymerase chain reaction technology as analytical tool in agricultural biotechnology. J AOAC Int 88:136–155
Martins TB (2002) Development of internal controls for the Luminex instrument as part of a multiplex seven-analyte viral respiratory antibody profile. Clin Diagn Lab Immunol 9:41–45
Miraglia M, Berdal KG, Brera C, Corbisier P, Holst-Jensen A, Kok EJ, Marvin HJ, Schimmel H, Rentsch J, van Rie JP, Zagon J (2004) Detection and traceability of genetically modified organisms in the food production chain. Food Chem Toxicol 42:1157–1180
Rutledge RG (2004) Sigmoidal curve-fitting redefines quantitative real-time PCR with the prospective of developing automated high-throughput applications. Nucleic Acids Res 32:e178
Seideman J, Peritt D (2002) A novel monoclonal antibody screening method using the Luminex-100 micro-sphere system. J Immunol Methods 267:165
Strom CM, Janeczko RA, Anderson B, Redman J, Quan F, Buller A, McGinniss MJ, Sun WM (2005) Technical validation of a multiplex platform to detect thirty mutations in eight genetic diseases prevalent in individuals of Ashkenazi Jewish descent. Genet Med 79:633–639
Taylor JD, Briley D, Nguyen Q (2001) Flow cytometric platform for high-throughput single nucleotide polymorphism analysis. Biotechniques3:661–666, 668–669
Tichopad A, Dilger M, Schwarz G, Pfaffl MW (2003) Standardized determination of real-time PCR efficiency from a single reaction set-up. Nucleic Acids Res 31:e122
Van LT, Paquet N, Calvo E, Cumps J (2005) Improved real-time RT-PCR method for high-throughput measurements using second derivative calculation and double correction. Biotechniques 38:287–293
Yang L, Tran DK, Wang X (2001) BADGE, Beads Array for the Detection of Gene Expression, a high-throughput diagnostic bioassay. Genome Res 11:1888–1898
Ye F, Li M, Taylor JD, Nguyen Q, Colton HM, Casey WM, Wagner M, Weiner MP, Chen J (2001) Fluorescent microsphere-based readout technology for multiplexed human single nucleotide polymorphism analysis and bacterial identification. Hum Mutat 17:305–316
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Fantozzi, A., Ermolli, M., Marini, M. et al. Innovative Application of Fluorescent Microsphere Based Assay for Multiple GMO Detection. Food Anal. Methods 1, 10–17 (2008). https://doi.org/10.1007/s12161-007-9005-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12161-007-9005-0