Astigmatism and optical coherence tomography measurements

  • Glaucoma
  • Published:
Graefe's Archive for Clinical and Experimental Ophthalmology Aims and scope Submit manuscript

Abstract

Background

To evaluate the effect of astigmatism change on measurement of retinal nerve fiber layer (RNFL) and macular thickness by Cirrus HD spectral-domain optical coherence tomography (Cirrus HD OCT; Carl Zeiss Meditec, Dublin, CA, USA).

Methods

A total of 30 right eyes from 30 healthy young subjects underwent RNFL and macular thickness measurements using Cirrus HD OCT. Measurements were performed at the baseline state and induced with-the-rule (WTR) and against-the-rule (ATR) astigmatism states by wearing toric soft contact lenses (+1.50 −3.25 diopter × 90° and +1.50 −3.25 diopter × 180° respectively). Dfferences in RNFL and macular thickness between the baseline state and induced astigmatism states were analyzed.

Results

Wearing toric soft contact lenses induced a mean 2.92 diopter WTR and 3.18 diopter ATR astigmatism respectively. After signal strength change adjustment, RNFL thicknesses of average, superior quadrant, 12 and 6 o’clock hour sectors decreased after induction of a WTR astigmatism (mean difference range, 1.58 to 6.88 μm); RNFL thicknesses of average, nasal, temporal quadrants, 2, 3, and 9 o’clock hour sectors decreased after induction of an ATR astigmatism (mean difference range, 0.75 to 5.11 μm) (all P values <0.05). Macular thickness was not significantly affected by astigmatism changes (all P values ≥ 0.250).

Conclusion

Although the amount of change was not substantial, RNFL thickness measured by Cirrus HD OCT was affected by astigmatism changes induced by contact lenses. It may be warranted to consider the effect of astigmatism on RNFL thickness measured by OCT in eyes with higher degrees of astigmatism.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

  1. Schuman JS, Hee MR, Puliafito CA, Wong C, Pedut-Kloizman T, Lin CP, Hertzmark E, Izatt JA, Swanson EA, Fujimoto JG (1995) Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography. Arch Ophthalmol 113:586–596

    Article  PubMed  CAS  Google Scholar 

  2. Budenz DL, Michael A, Chang RT, McSoley J, Katz J (2005) Sensitivity and specificity of the StratusOCT for perimetric glaucoma. Ophthalmology 112:3–9

    Article  PubMed  Google Scholar 

  3. Medeiros FA, Zangwill LM, Bowd C, Vessani RM, Susanna R Jr, Weinreb RN (2005) Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. Am J Ophthalmol 139:44–55

    Article  PubMed  Google Scholar 

  4. Budenz DL, Anderson DR, Varma R, Schuman J, Cantor L, Savell J, Greenfield DS, Patella VM, Quigley HA, Tielsch J (2007) Determinants of normal retinal nerve fiber layer thickness measured by Stratus OCT. Ophthalmology 114:1046–1052

    Article  PubMed  Google Scholar 

  5. Leung CK, Mohamed S, Leung KS, Cheung CY, Chan SL, Cheng DK, Lee AK, Leung GY, Rao SK, Lam DS (2006) Retinal nerve fiber layer measurements in myopia: An optical coherence tomography study. Invest Ophthalmol Vis Sci 47:5171–5176

    Article  PubMed  Google Scholar 

  6. Hwang YH, Yoo C, Kim YY (2011) Myopic optic disc tilt and the characteristics of peripapillary retinal nerve fiber layer thickness measured by spectral-domain optical coherence tomography. J Glaucoma May 26 [Epub ahead of print]. doi:10.1097/IJG.0b013e31820719e1

  7. Kang SH, Hong SW, Im SK, Lee SH, Ahn MD (2010) Effect of myopia on the thickness of the retinal nerve fiber layer measured by Cirrus HD optical coherence tomography. Invest Ophthalmol Vis Sci 51:4075–4083

    Article  PubMed  Google Scholar 

  8. Savini G, Barboni P, Parisi V, Carbonelli M (2011) The influence of axial length on retinal nerve fibre layer thickness and optic-disc size measurements by spectral-domain OCT. Br J Ophthalmol Feb 24 [Epub ahead of print]. doi:10.1136/bjo.2010.196782

  9. Cheung CY, Leung CK, Lin D, Pang CP, Lam DS (2008) Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography. Ophthalmology 115:1347–1351

    Article  PubMed  Google Scholar 

  10. Vizzeri G, Bowd C, Medeiros FA, Weinreb RN, Zangwill LM (2009) Effect of signal strength and improper alignment on the variability of Stratus optical coherence tomography retinal nerve fiber layer thickness measurements. Am J Ophthalmol 148:249–255

    Article  PubMed  Google Scholar 

  11. Yoo C, Suh IH, Kim YY (2009) The influence of eccentric scanning of optical coherence tomography on retinal nerve fiber layer analysis in normal subjects. Ophthalmologica 223:326–332

    Article  PubMed  Google Scholar 

  12. Hwang YH, Lee JY, Kim YY (2011) The effect of head tilt on the measurements of retinal nerve fiber layer and macular thickness by spectral-domain optical coherence tomography. Br J Ophthalmol Feb 24 [Epub ahead of print]. doi:10.1136/bjo.2010.194118

  13. Sharma N, Sony P, Gupta A, Vajpayee RB (2006) Effect of laser in situ keratomileusis and laser-assisted subepithelial keratectomy on retinal nerve fiber layer thickness. J Cataract Refract Surg 32:446–450

    Article  PubMed  Google Scholar 

  14. Gürses-Ozden R, Liebmann JM, Schuffner D, Buxton DF, Soloway BD, Ritch R (2001) Retinal nerve fiber layer thickness remains unchanged following laser-assisted in situ keratomileusis. Am J Ophthalmol 132:512–516

    Article  PubMed  Google Scholar 

  15. Zangwill LM, Abunto T, Bowd C, Angeles R, Schanzlin DJ, Weinreb RN (2005) Scanning laser polarimetry retinal nerve fiber layer thickness measurements after LASIK. Ophthalmology 112:200–207

    Article  PubMed  Google Scholar 

  16. Salchow DJ, Hwang AM, Li FY, Dziura J (2011) Effect of contact lens power on optical coherence tomography of the retinal nerve fiber layer. Invest Ophthalmol Vis Sci 52:1650–1654

    Article  PubMed  Google Scholar 

  17. Lee J, Kim NR, Kim H, Han J, Lee ES, Seong GJ, Kim CY (2010) Negative refraction power causes underestimation of peripapillary retinal nerve fibre layer thickness in spectral-domain optical coherence tomography tomography. Br J Ophthalmol Oct 17 [Epub ahead of print]. doi:10.1136/bjo.2010.186536

  18. Langenbucher A, Viestenz A, Seitz B, Brünner H (2007) Computerized calculation scheme for retinal image size after implantation of toric intraocular lenses. Acta Ophthalmol Scand 85:92–98

    Article  PubMed  Google Scholar 

  19. Hoffmann PC, Hutz WW (2010) Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes. J Cataract Refract Surg 36:1479–1485

    Article  PubMed  Google Scholar 

  20. Fozailoff A, Tarczy-Hornoch K, Cotter S, Wen G, Lin J, Borchert M, Azen S, Varma R (2011) Prevalence of astigmatism in 6- to 72-month-old African American and Hispanic children: The Multi-Ethnic Pediatric Eye Disease Study. Ophthalmology 118:284–293

    Article  PubMed  Google Scholar 

  21. Thibos LN, Horner D (2001) Power vector analysis of the optical outcome of refractive surgery. J Cataract Refract Surg 27:80–85

    Article  PubMed  CAS  Google Scholar 

  22. Gabriele ML, Ishikawa H, Wollstein G, Bilonick RA, Kagemann L, Wojtkowski M, Srinivasan VJ, Fujimoto JG, Duker JS, Schuman JS (2007) Peripapillary nerve fiber layer thickness profile determined with high speed, ultrahigh resolution optical coherence tomography high-density scanning. Invest Ophthalmol Vis Sci 48:3154–3160

    Article  PubMed  Google Scholar 

  23. Savini G, Zanini M, Carelli V, Sadun AA, Ross-Cisneros FN, Barboni P (2005) Correlation between retinal nerve fiber layer thickness and optic nerve head size: an optical coherence tomography study. Br J Ophthalmol 89:489–492

    Article  PubMed  CAS  Google Scholar 

  24. Campbell RJ, Coupland SG, Buhrmann RR, Kertes PJ (2007) Effect of eccentric and inconsistent fixation on retinal optical coherence tomography measures. Arch Ophthalmol 125:624–627

    Article  PubMed  Google Scholar 

  25. Sull AC, Vuong LN, Price LL, Srinivasan VJ, Gorczynska I, Fujimoto JG, Schuman JS, Duker JS (2010) Comparison of spectral/Fourier domain optical coherence tomography instruments for assessment of normal macular thickness. Retina 30:235–245

    Article  PubMed  Google Scholar 

  26. Mwanza JC, Chang RT, Budenz DL, Durbin MK, Gendy MG, Shi W, Feuer WJ (2010) Reproducibility of peripapillary retinal nerve fiber layer thickness and optic nerve head parameters measured with Cirrus HD-OCT in glaucomatous eyes. Invest Ophthalmol Vis Sci 51:5724–5730

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

The authors have no financial or proprietary interest in any of the materials or methods mentioned.

Financial disclosure

None to declare

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yong Yeon Kim.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hwang, Y.H., Lee, S.M., Kim, Y.Y. et al. Astigmatism and optical coherence tomography measurements. Graefes Arch Clin Exp Ophthalmol 250, 247–254 (2012). https://doi.org/10.1007/s00417-011-1788-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00417-011-1788-4