Abstract

The conventional distance protection technique malfunctions in case of a double circuit transmission line during simultaneous faulty conditions. To mitigate this problem, an adaptive neuro fuzzy inference system with different membership functions and discrete Fourier transform-based technique has been presented in this paper. A 400 kV, 50 Hz double circuit transmission line is simulated in PSCAD software, while the fault location technique is implemented in MATLAB software. The fundamental components of phase voltages and phase currents are fed as inputs to the proposed technique. The proposed technique is investigated under various fault inception angles and fault locations as well as all possible fault cases including shunt and series faults. Its effectiveness is checked through PSCAD simulations, and the results prove that it can be employed in the simultaneous fault locating of double circuit transmission line. The simulation study with mathematical validation promises the validation of the technique for all fault cases.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  • Anubha G, Sunil VC, Bhat SS (2014) Simultaneous fault analysis. International conference on power automation and communication, pp 33–38

  • Apostolopoulos CA, Korres GN (2011) A novel fault-location algorithm for double-circuit transmission lines without utilizing line parameters. IEEE Trans Power Delivery 26(3):1467–1478

    Article  Google Scholar 

  • Bystrov D, Westin J. Practice. Neuro-fuzzy logic systems MATLAB Toolbox GUI (to be appear)

  • Cook V (1977) Distance protection performance during simultaneous fault. In: Proceedings of the institution of electrical engineers, 124, No. 2, pp 141–146

  • Elkalashy NI, Kawady TA, Khater WM, Taalab AI (2016) Unsynchronized fault-location technique for double-circuit transmission systems independent of line parameters. IEEE Trans Power Delivery 31(4):1591–1600

    Article  Google Scholar 

  • Ghorbani A, Mehrjerdi H (2019) Negative-sequence network based fault location scheme for double-circuit multi-terminal transmission lines. IEEE Trans Power Delivery 34(3):1109–1117

    Article  Google Scholar 

  • Jain A, Thoke AS, Patel RN (2009) Double circuit transmission line fault distance location using artificial neural network, paper no. 67. In: Proceedings of World Congress on Nature and Biologically Inspired Computing (NaBIC’09 conference) at Coimbatore, India

  • Jain A, Thoke AS, Patel RN, Modi PK (2010) Classification and location of single line to ground faults in double circuit transmission lines using artificial neural networks. Int J Power Energy Convers 2(2):109–125

    Article  Google Scholar 

  • Kang N, Liao Y (2013) Double-circuit transmission-line fault location utilizing synchronized current phasors. IEEE Trans Power Delivery 28(2):1040–1047

    Article  Google Scholar 

  • Makwana VH, Bhalja BR (2012) A new digital distance relaying scheme for series-compensated double-circuit line during open conductor and ground fault. IEEE Trans Power Delivery 27(2):910–917

    Article  Google Scholar 

  • Naresh Kumar A, Chakravarthy M (2018) Simultaneous fault classification and localization scheme in six phase transmission line using artificial neural networks. J Adv Res Dyn Control Syst. 10:342–349

    Google Scholar 

  • Naresh Kumar A, Sanjay C, Chakravarthy M (2019) Fuzzy inference system-based solution to locate the cross-country faults in parallel transmission line. Int J Electr Eng Educ. https://doi.org/10.1177/0020720919830905

    Article  Google Scholar 

  • Reddy MJ, Mohanta DK (2007) A wavelet-neuro-fuzzy combined approach for digital relaying of transmission line faults. Electric Power Compon Syst 35(12):1385-40

    Article  Google Scholar 

  • Roy L, Rao ND (1982) Exact calculation of simultaneous faults involving open conductors and line-to-ground short circuits on inherently unbalanced power systems. IEEE Trans Power Appar Syst 8:2738–2746

    Article  Google Scholar 

  • Sadeh Javad, Afradi Hamid (2009) A new and accurate fault location algorithm for combined transmission lines using adaptive network-based fuzzy inference system. Electric Power Systems Research 79:1538–1545

    Article  Google Scholar 

  • Sekhar GC, Subramanyam PS (2016) A logic based protection scheme for six phase transmission system against shunt and series faults. World J Model Simul 12(2):125–136

    Google Scholar 

  • Swetapadma A, Yadav A (2015) Fuzzy inference system approach for locating series, shunt, and simultaneous series-shunt faults in double circuit transmission lines. Comput Intell Neurosci 2015:79

    Article  Google Scholar 

  • Swetapadma A, Yadav A (2018) A novel single ended fault location scheme for parallel transmission lines using k-nearest neighbor algorithm. Comput Electr Eng 69:41–53

    Article  Google Scholar 

  • Swetapadma Aleena, Yadav Anamika (2016) Fuzzy based fault location estimation during unearthed open conductor faults in double circuit transmission line. Adv Intell Syst Comput 434:445–456

    Google Scholar 

  • Youssef KH, Abouelenin FM (2016) Analysis of simultaneous unbalanced short circuit and open conductor faults in power systems with untransposed lines and six-phase sections. Alex Eng J 55(1):369–377

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. Naresh Kumar.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kumar, A.N., Sanjay, C. & Chakravarthy, M. Adaptive neuro fuzzy inference system-based fault location technique in double circuit transmission line against simultaneous faults. Multiscale and Multidiscip. Model. Exp. and Des. 3, 143–150 (2020). https://doi.org/10.1007/s41939-019-00066-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s41939-019-00066-x

Keywords

Navigation